Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 7-Day Trial for You or Your Team.

Learn More →

Stable cationic capillary coating with successive multiple ionic polymer layers for capillary electrophoresis.

Stable cationic capillary coating with successive multiple ionic polymer layers for capillary... A coated capillary modified with a cationic polymer was developed by using a novel coating procedure, successive multiple ionic-polymer (SMIL) coating. The SMIL coating was achieved by first attaching the cationic polymer to the capillary inner wall, and then the anionic polymer to the cationic polymer layer, and finally the cationic polymer to the anionic polymer layer. The stability of Polybrene (PB)-modified capillary made by SMIL coating was remarkably improved in comparison with a conventional PB-modified capillary. It endured during 600 replicate analyses and also showed strong stability against 1 M NaOH and 0.1 M HCl. The relative standard deviation of the run-to-run, day-to-day, and capillary-to-capillary coating was all below 1%, and good reproducibilities were obtained. The PB-modified capillary made by SMIL coating was applied to the basic protein analyses. It gave good performances for the protein analyses even when the pH of the electrolyte was near the isoelectric point (pI) of the protein. In addition, 0.1 M NaOH rinse prior to the sample injection allowed the reproducible analysis of a highly adsorptive sample such as plasma because the adsorbed sample could be flushed out of the capillary. Besides protein analyses, an efficient analysis of the cationic drugs by capillary electrophoresis/mass spectrometry (CE/MS) was also possible. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Analytical Chemistry Pubmed

Stable cationic capillary coating with successive multiple ionic polymer layers for capillary electrophoresis.

Analytical Chemistry , Volume 70 (24): -5264 – Jan 28, 1999

Stable cationic capillary coating with successive multiple ionic polymer layers for capillary electrophoresis.


Abstract

A coated capillary modified with a cationic polymer was developed by using a novel coating procedure, successive multiple ionic-polymer (SMIL) coating. The SMIL coating was achieved by first attaching the cationic polymer to the capillary inner wall, and then the anionic polymer to the cationic polymer layer, and finally the cationic polymer to the anionic polymer layer. The stability of Polybrene (PB)-modified capillary made by SMIL coating was remarkably improved in comparison with a conventional PB-modified capillary. It endured during 600 replicate analyses and also showed strong stability against 1 M NaOH and 0.1 M HCl. The relative standard deviation of the run-to-run, day-to-day, and capillary-to-capillary coating was all below 1%, and good reproducibilities were obtained. The PB-modified capillary made by SMIL coating was applied to the basic protein analyses. It gave good performances for the protein analyses even when the pH of the electrolyte was near the isoelectric point (pI) of the protein. In addition, 0.1 M NaOH rinse prior to the sample injection allowed the reproducible analysis of a highly adsorptive sample such as plasma because the adsorbed sample could be flushed out of the capillary. Besides protein analyses, an efficient analysis of the cationic drugs by capillary electrophoresis/mass spectrometry (CE/MS) was also possible.

Loading next page...
 
/lp/pubmed/stable-cationic-capillary-coating-with-successive-multiple-ionic-s4lF3vabVG

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

ISSN
0003-2700
DOI
10.1021/ac980522l
pmid
9868917

Abstract

A coated capillary modified with a cationic polymer was developed by using a novel coating procedure, successive multiple ionic-polymer (SMIL) coating. The SMIL coating was achieved by first attaching the cationic polymer to the capillary inner wall, and then the anionic polymer to the cationic polymer layer, and finally the cationic polymer to the anionic polymer layer. The stability of Polybrene (PB)-modified capillary made by SMIL coating was remarkably improved in comparison with a conventional PB-modified capillary. It endured during 600 replicate analyses and also showed strong stability against 1 M NaOH and 0.1 M HCl. The relative standard deviation of the run-to-run, day-to-day, and capillary-to-capillary coating was all below 1%, and good reproducibilities were obtained. The PB-modified capillary made by SMIL coating was applied to the basic protein analyses. It gave good performances for the protein analyses even when the pH of the electrolyte was near the isoelectric point (pI) of the protein. In addition, 0.1 M NaOH rinse prior to the sample injection allowed the reproducible analysis of a highly adsorptive sample such as plasma because the adsorbed sample could be flushed out of the capillary. Besides protein analyses, an efficient analysis of the cationic drugs by capillary electrophoresis/mass spectrometry (CE/MS) was also possible.

Journal

Analytical ChemistryPubmed

Published: Jan 28, 1999

There are no references for this article.