Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 7-Day Trial for You or Your Team.

Learn More →

An Enzyme Immunoassay for Rat Prolactin: Application to the Determination of Plasma Levels

An Enzyme Immunoassay for Rat Prolactin: Application to the Determination of Plasma Levels Abstract Pure acetylcholinesterase (EC 3. 1. 1. 7) from Electrophorus electricus has been covalently coupled to rat prolactin using the heterobifunctional reagent : N-succinimidyl-4 (N-maleimidomethyl) cyclohexane-1-carboxylate (SMCC). This conjugate was used as a tracer in a competitive enzyme imunoassay using a rabbit antiserum, raised against rat prolactin, as first antibody. The assay was performed in 96-well microtiter plates coated with a mouse monoclonal anti-rabbit immunoglobulin antibody. This second antibody solid phase ensured separation of bound and free moieties of the tracer during the specific immunoreaction. The total reaction volume was 150 μl. Each component (tracer, antiserum and standard) was added in a volume of 50 μl. The sensitivity of the assay was good since calculation indicated a detection thueshold of 25 pg (0.5 ng/ml) and a B/Bo 50%/value of 220 pg (4.4 ng/ml). Intra-assay variation was better than 10% over a wide range (135 to 2500 pg) with an optimum of 4% at 300 pg. The inter-assay coefficient of variation was less than 15% for rat plasma samples in the concentration range of 8 to 1000 ng/ml. The good parallelism observed between the standard curve and sample dilution curves, and recovery experiments, indicated that direct assay is possible. This was confirmed by molecular sieve fractionation of plasma samples. The reliability of the assay was confirmed by good correlation with conventional radioimmunoassay (r = 0.996, slope = 0.978). http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Immunoassay Taylor & Francis

An Enzyme Immunoassay for Rat Prolactin: Application to the Determination of Plasma Levels

An Enzyme Immunoassay for Rat Prolactin: Application to the Determination of Plasma Levels

Journal of Immunoassay , Volume 12 (2): 18 – Jun 1, 1991

Abstract

Abstract Pure acetylcholinesterase (EC 3. 1. 1. 7) from Electrophorus electricus has been covalently coupled to rat prolactin using the heterobifunctional reagent : N-succinimidyl-4 (N-maleimidomethyl) cyclohexane-1-carboxylate (SMCC). This conjugate was used as a tracer in a competitive enzyme imunoassay using a rabbit antiserum, raised against rat prolactin, as first antibody. The assay was performed in 96-well microtiter plates coated with a mouse monoclonal anti-rabbit immunoglobulin antibody. This second antibody solid phase ensured separation of bound and free moieties of the tracer during the specific immunoreaction. The total reaction volume was 150 μl. Each component (tracer, antiserum and standard) was added in a volume of 50 μl. The sensitivity of the assay was good since calculation indicated a detection thueshold of 25 pg (0.5 ng/ml) and a B/Bo 50%/value of 220 pg (4.4 ng/ml). Intra-assay variation was better than 10% over a wide range (135 to 2500 pg) with an optimum of 4% at 300 pg. The inter-assay coefficient of variation was less than 15% for rat plasma samples in the concentration range of 8 to 1000 ng/ml. The good parallelism observed between the standard curve and sample dilution curves, and recovery experiments, indicated that direct assay is possible. This was confirmed by molecular sieve fractionation of plasma samples. The reliability of the assay was confirmed by good correlation with conventional radioimmunoassay (r = 0.996, slope = 0.978).

Loading next page...
 
/lp/taylor-francis/an-enzyme-immunoassay-for-rat-prolactin-application-to-the-bNcW3SOuCR

References (19)

Publisher
Taylor & Francis
Copyright
Copyright Taylor & Francis Group, LLC
ISSN
0197-1522
DOI
10.1080/01971529108055069
Publisher site
See Article on Publisher Site

Abstract

Abstract Pure acetylcholinesterase (EC 3. 1. 1. 7) from Electrophorus electricus has been covalently coupled to rat prolactin using the heterobifunctional reagent : N-succinimidyl-4 (N-maleimidomethyl) cyclohexane-1-carboxylate (SMCC). This conjugate was used as a tracer in a competitive enzyme imunoassay using a rabbit antiserum, raised against rat prolactin, as first antibody. The assay was performed in 96-well microtiter plates coated with a mouse monoclonal anti-rabbit immunoglobulin antibody. This second antibody solid phase ensured separation of bound and free moieties of the tracer during the specific immunoreaction. The total reaction volume was 150 μl. Each component (tracer, antiserum and standard) was added in a volume of 50 μl. The sensitivity of the assay was good since calculation indicated a detection thueshold of 25 pg (0.5 ng/ml) and a B/Bo 50%/value of 220 pg (4.4 ng/ml). Intra-assay variation was better than 10% over a wide range (135 to 2500 pg) with an optimum of 4% at 300 pg. The inter-assay coefficient of variation was less than 15% for rat plasma samples in the concentration range of 8 to 1000 ng/ml. The good parallelism observed between the standard curve and sample dilution curves, and recovery experiments, indicated that direct assay is possible. This was confirmed by molecular sieve fractionation of plasma samples. The reliability of the assay was confirmed by good correlation with conventional radioimmunoassay (r = 0.996, slope = 0.978).

Journal

Journal of ImmunoassayTaylor & Francis

Published: Jun 1, 1991

Keywords: Acetylcholinesterase; rat prolactin; enzyme immunoassay; plasma

There are no references for this article.