Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 7-Day Trial for You or Your Team.

Learn More →

Automated Optimised High Performance Liquid Chromatographic Analysis of Pre-Column O-Phthaldialdehyde-Amino Acid Derivatives

Automated Optimised High Performance Liquid Chromatographic Analysis of Pre-Column... Abstract The feasibility of injecting o-phthaldialdehyde/2-mercaptoethanol reagent and amino acid mixture simultaneously, from separate Injector vials in order to allow automation of HPLC pre-column amino acid derivative analysis was investigated. The modified duel injection system described proved to be successful. Reaction of amino acids and reagent takes place during flushing of the injection loop. This is immediately followed by the introduction of the formed derivatives into the main HPLC eluent stream leading to the chromatographic column. The described procedure gave reproducible results with no loss in sensitivity. Further established was the optimum pH of reagent for derivative formation and of eluents for the separation of derivatives. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Liquid Chromatography Taylor & Francis

Automated Optimised High Performance Liquid Chromatographic Analysis of Pre-Column O-Phthaldialdehyde-Amino Acid Derivatives

Journal of Liquid Chromatography , Volume 7 (10): 12 – Sep 1, 1984

Automated Optimised High Performance Liquid Chromatographic Analysis of Pre-Column O-Phthaldialdehyde-Amino Acid Derivatives

Journal of Liquid Chromatography , Volume 7 (10): 12 – Sep 1, 1984

Abstract

Abstract The feasibility of injecting o-phthaldialdehyde/2-mercaptoethanol reagent and amino acid mixture simultaneously, from separate Injector vials in order to allow automation of HPLC pre-column amino acid derivative analysis was investigated. The modified duel injection system described proved to be successful. Reaction of amino acids and reagent takes place during flushing of the injection loop. This is immediately followed by the introduction of the formed derivatives into the main HPLC eluent stream leading to the chromatographic column. The described procedure gave reproducible results with no loss in sensitivity. Further established was the optimum pH of reagent for derivative formation and of eluents for the separation of derivatives.

Loading next page...
 
/lp/taylor-francis/automated-optimised-high-performance-liquid-chromatographic-analysis-PLutyicJrO

References (4)

Publisher
Taylor & Francis
Copyright
Copyright Taylor & Francis Group, LLC
ISSN
0148-3919
DOI
10.1080/01483918408068850
Publisher site
See Article on Publisher Site

Abstract

Abstract The feasibility of injecting o-phthaldialdehyde/2-mercaptoethanol reagent and amino acid mixture simultaneously, from separate Injector vials in order to allow automation of HPLC pre-column amino acid derivative analysis was investigated. The modified duel injection system described proved to be successful. Reaction of amino acids and reagent takes place during flushing of the injection loop. This is immediately followed by the introduction of the formed derivatives into the main HPLC eluent stream leading to the chromatographic column. The described procedure gave reproducible results with no loss in sensitivity. Further established was the optimum pH of reagent for derivative formation and of eluents for the separation of derivatives.

Journal

Journal of Liquid ChromatographyTaylor & Francis

Published: Sep 1, 1984

There are no references for this article.