Access the full text.
Sign up today, get DeepDyve free for 14 days.
J. Boston, J. Antaki, M. Simaan (2003)
Hierarchical control of heart-assist devicesIEEE Robotics Autom. Mag., 10
A. Stephens, S. Gregory, R. Salamonsen (2018)
The Importance of Venous Return in Starling‐Like Control of Rotary Ventricular Assist DevicesArtificial Organs, 43
A. Stephens, M. Stevens, S. Gregory, M. Kleinheyer, R. Salamonsen (2017)
In Vitro Evaluation of an Immediate Response Starling‐Like Controller for Dual Rotary Blood PumpsArtificial Organs, 41
N. Gaddum, D. Timms, M. Stevens, D. Mason, N. Lovell, J. Fraser (2012)
Comparison of preload-sensitive pressure and flow controller strategies for a dual device biventricular support system.Artificial organs, 36 3
M. Slaughter, F. Pagani, J. Rogers, L. Miller, B. Sun, S. Russell, R. Starling, Leway Chen, A. Boyle, S. Chillcott, R. Adamson, M. Blood, M. Camacho, K. Idrissi, M. Petty, M. Sobieski, S. Wright, T. Myers, D. Farrar (2010)
Clinical management of continuous-flow left ventricular assist devices in advanced heart failure.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation, 29 4 Suppl
K. Muthiah, D. Humphreys, D. Robson, K. Dhital, P. Spratt, P. Jansz, P. Macdonald, C. Hayward (2017)
Longitudinal structural, functional, and cellular myocardial alterations with chronic centrifugal continuous-flow left ventricular assist device support.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation, 36 7
R. Salamonsen, E. Lim, N. Gaddum, A. AlOmari, S. Gregory, M. Stevens, D. Mason, J. Fraser, D. Timms, M. Karunanithi, N. Lovell (2012)
Theoretical foundations of a Starling-like controller for rotary blood pumps.Artificial organs, 36 9
L. Brancato, G. Keulemans, T. Verbelen, B. Meyns, R. Puers (2016)
An Implantable Intravascular Pressure Sensor for a Ventricular Assist DeviceMicromachines, 7
D. Timms, S. Gregory, N. Greatrex, M. Pearcy, J. Fraser, U. Steinseifer (2010)
A compact mock circulation loop for the in vitro testing of cardiovascular devices.Artificial organs, 35 4
N. Gaddum, M. Stevens, E. Lim, J. Fraser, N. Lovell, D. Mason, D. Timms, R. Salamonsen (2014)
Starling-like flow control of a left ventricular assist device: in vitro validation.Artificial organs, 38 3
SD Gregory, M Stevens, D Timms, M Pearcy (2011)
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society
A. Petrou, Jongseok Lee, S. Dual, Gregor Ochsner, M. Meboldt, M. Daners (2018)
Standardized Comparison of Selected Physiological Controllers for Rotary Blood Pumps: In Vitro StudyArtificial Organs, 42
B. Ng, P. Smith, F. Nestler, D. Timms, W. Cohn, E. Lim (2017)
Application of Adaptive Starling-Like Controller to Total Artificial Heart Using Dual Rotary Blood PumpsAnnals of Biomedical Engineering, 45
R. Salamonsen, D. Mason, P. Ayre (2011)
Response of rotary blood pumps to changes in preload and afterload at a fixed speed setting are unphysiological when compared with the natural heart.Artificial organs, 35 3
JP Pauls (2017)
Development of a passive control system for ventricular assist devices
AC Guyton, JE Hall (2006)
Textbook of medical physiology
V. Tchantchaleishvili, Jessica Luc, Caitlin Cohan, K. Phan, L. Hübbert, S. Day, H. Massey (2017)
Clinical Implications of Physiologic Flow Adjustment in Continuous-Flow Left Ventricular Assist DevicesASAIO Journal, 63
Dipanjan Banerjee, D. Dutt, S. Duclos, Karim Sallam, M. Wheeler, R. Ha (2017)
Simultaneous ramp right heart catheterization and echocardiography in a ReliantHeart left ventricular assist deviceWorld Journal of Cardiology, 9
S. Saito, T. Sakaguchi, S. Miyagawa, Y. Yoshikawa, Takashi Yamauchi, T. Ueno, T. Kuratani, Y. Sawa (2011)
Biventricular support using implantable continuous-flow ventricular assist devices.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation, 30 4
Mahdi Mansouri, R. Salamonsen, E. Lim, Rini Akmeliawati, N. Lovell (2015)
Preload-Based Starling-Like Control for Rotary Blood Pumps: Numerical Comparison with Pulsatility Control and Constant Speed OperationPLoS ONE, 10
S. Epstein, G. Beiser, M. Stampfer, B. Robinson, E. Braunwald (1967)
Characterization of the Circulatory Response to Maximal Upright Exercise in Normal Subjects and Patients with Heart DiseaseCirculation, 35
Peter Starr, K. Bartels, C. Agrawal, S. Bailey (2016)
A thin-film pressure transducer for implantable and intravascular blood pressure sensingSensors and Actuators A-physical, 248
A. Guyton (1955)
Determination of cardiac output by equating venous return curves with cardiac response curves.Physiological reviews, 35 1
J. Pauls, M. Stevens, Emma Schummy, G. Tansley, J. Fraser, D. Timms, S. Gregory (2015)
In Vitro Comparison of Active and Passive Physiological Control Systems for Biventricular Assist DevicesAnnals of Biomedical Engineering, 44
S. Sarnoff (1955)
Myocardial contractility as described by ventricular function curves; observations on Starling's law of the heart.Physiological reviews, 35 1
E. Starling, M. Visscher (1927)
The regulation of the energy output of the heartThe Journal of Physiology, 62
K. Fukamachi, A. Shiose, A. Massiello, D. Horvath, L. Golding, Sangjin Lee, R. Starling (2013)
Preload sensitivity in cardiac assist devices.The Annals of thoracic surgery, 95 1
D. Timms, E. Gude, N. Gaddum, E. Lim, N. Greatrex, K. Wong, U. Steinseifer, N. Lovell, J. Fraser, A. Fiane (2011)
Assessment of right pump outflow banding and speed changes on pulmonary hemodynamics during biventricular support with two rotary left ventricular assist devices.Artificial organs, 35 8
J. Coote (1982)
Respiratory and circulatory control during sleep.The Journal of experimental biology, 100
J. Pauls, M. Stevens, N. Bartnikowski, J. Fraser, S. Gregory, G. Tansley (2016)
Evaluation of Physiological Control Systems for Rotary Left Ventricular Assist Devices: An In-Vitro StudyAnnals of Biomedical Engineering, 44
Rotary ventricular assist devices (VADs) operated clinically under constant speed control (CSC) cannot respond adequately to changes in patient cardiac demand, resulting in sub‐optimal VAD flow regulation. Starling‐like control (SLC) of VADs mimics the healthy ventricular flow regulation and automatically adjusts VAD speed to meet varying patient cardiac demand. The use of a fixed control line (CL – the relationship between ventricular preload and VAD flow) limits the flow regulating capability of the controller, especially in the case of exercise. Adaptive SLC (ASLC) overcomes this limitation by allowing the controller to adapt the CL to meet a diverse range of circulatory conditions. This study evaluated ASLC, SLC and CSC in a biventricular supported mock circulation loop under the simulated conditions of exercise, sleep, fluid loading and systemic hypertension. Each controller was evaluated on its ability to remain within predefined limits of VAD flow, preload, and afterload. The ASLC produced superior cardiac output (CO) during exercise (10.1 L/min) compared to SLC (7.3 L/min) and CSC (6.3 L/min). The ASLC produced favourable haemodynamics during sleep, fluid loading and systemic hypertension and could remain within a predefined haemodynamic range in three out of four simulations, suggesting improved haemodynamic performance over SLC and CSC.
Artificial Organs – Wiley
Published: Nov 1, 2019
Keywords: ; ; ; ; ; ;
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.