Access the full text.
Sign up today, get DeepDyve free for 14 days.
M. Schubert, M. Wiggins, M. Schaefer, A. Hiltner, James Anderson (1995)
Oxidative biodegradation mechanisms of biaxially strained poly(etherurethane urea) elastomers.Journal of biomedical materials research, 29 3
Q. Zhao, M. Agger, M. Fitzpatrick, J. Anderson, A. Hiltner, K. Stokes, P. Urbański (1990)
Cellular interactions with biomaterials: in vivo cracking of pre-stressed Pellethane 2363-80A.Journal of biomedical materials research, 24 5
Q. Zhao, N. Topham, James Anderson, A. Hiltner, G. Lodoen, C. Payet (1991)
Foreign-body giant cells and polyurethane biostability: in vivo correlation of cell adhesion and surface cracking.Journal of biomedical materials research, 25 2
James Anderson (1988)
Inflammatory response to implants.ASAIO transactions, 34 2
J Anderson (1993)
Mechanisms of inflammation and infection with implanted devices, 2
M. Schubert, M. Wiggins, J. Anderson, A. Hiltner (1997)
The effect of strain state on the biostability of a poly(etherurethane urea) elastomer.Journal of biomedical materials research, 35 3
K. Stokes, A. Coury, Peter Urbanski (1986)
Autooxidative Degradation of Implanted Polyether Polyurethane DevicesJournal of Biomaterials Applications, 1
N. Lamba (1997)
Polyurethanes in Biomedical Applications
Laurence Epstein, Charles Byrd, Bruce Wilkoff, Charles Love, T. Sellers, David Hayes, Christopher Reiser (1999)
Initial experience with larger laser sheaths for the removal of transvenous pacemaker and implantable defibrillator leads.Circulation, 100 5
K. Stokes, J. Anderson, R. Mcvenes, C. McClay (1995)
The encapsulation of polyurethane-insulated transvenous cardiac pacemaker leads.Cardiovascular pathology : the official journal of the Society for Cardiovascular Pathology, 4 3
R. Candinas, F. Duru, J. Schneider, T. Lüscher, K. Stokes (1999)
Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads.Mayo Clinic proceedings, 74 2
Leonard Pinchuk (1994)
A review of the biostability and carcinogenicity of polyurethanes in medicine and the new generation of 'biostable' polyurethanes.Journal of biomaterials science. Polymer edition, 6 3
Y. Sibille, H. Reynolds (1990)
Macrophages and polymorphonuclear neutrophils in lung defense and injury.The American review of respiratory disease, 141 2
James Anderson (1993)
Chapter 4 Mechanisms of inflammation and infection with implanted devicesCardiovascular Pathology, 2
K. Stokes (1988)
Polyether Polyurethanes: Biostable or Not?Journal of Biomaterials Applications, 3
J. Schmidt, L. Stotts (1998)
Bipolar pacemaker leads: new materials, new technology.Journal of investigative surgery : the official journal of the Academy of Surgical Research, 11 1
Several bipolar coaxial pacemaker leads, composed of an outer silicone rubber insulation and an inner polyether polyurethane (PEU) insulation, which were explanted due to clinical evidence of electrical dysfunction, were analyzed in this study. Optical microscopy (OM) and scanning electron microscopy (SEM) were used to determine the cause of failure. Attenuated total reflectance‐Fourier transform infrared microscopy (ATR‐FTIR) was used to analyze the PEU insulation for chemical degradation. In all leads, the silicone rubber outer insulation showed no signs of physical damage. Physical damage to the inner PEU insulation was the source of electrical dysfunction. Cracks through the PEU compromised the insulation between the inner and outer conductor coils in the lead. It was observed with SEM that these cracks originated on the outer surface of the inner insulation and progressed inward. ATR‐FTIR analysis showed that the PEU had chemically degraded via oxidation of the ether soft segment. Furthermore, it was revealed that chemical degradation was more advanced on the outer surface of the PEU. It was hypothesized that hydrogen peroxide permeated through the outer silicone insulation and decomposed into hydroxyl radicals that caused the chemical degradation of PEU. The metal in the outer conductor coil catalyzed the decomposition of the hydrogen peroxide. Chemical degradation of the PEU could also have been catalyzed by metal ions created from the corrosion of the metal in the outer conductor coil by hydrogen peroxide. Physical damage probably occurred in regions of the leads that were subjected to a higher hydrogen peroxide concentration from inflammatory cells and high degrees and rates of strain due to intercorporeal movement, including, but not limited to, cardiac movement. Chemical degradation and physical damage probably had a synergistic affect on failure of the insulation, in that as chemical degradation proceeded, the polymer surface became brittle and more susceptible to physical damage. As physical damage proceeded, cracks propagated into the unaffected bulk, exposing it to oxidants. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 58: 302–307, 2001
Journal of Biomedical Materials Research Part A – Wiley
Published: Jan 1, 2001
Keywords: ; ; ;
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.