Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 7-Day Trial for You or Your Team.

Learn More →

Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan

Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan The anisotropy of the water diffusion tensor inside brain causes contrast in diffusion images, which depends on the relative orientation of the diffusion gradients and the subject. Because the trace of a tensor is invariant upon rotation, measurement of this trace can reduce the orientation effect. A family of imaging pulse sequences is presented in which the signal intensity is weighted by the trace of the diffusion tensor in a single scan. The methods are demonstrated for chicken gizzard in several orientations with respect to the gradient frame of reference, and for ischemic injury in cat brain after middle cerebral artery occlusion. The sensitivity of the techniques to the presence of background gradients is measured and discussed in detail. As a result, pulse sequences are suggested that provide reliable diffusion constants in both homogeneous and inhomogeneous magnetic fields. The efficiency of the techniques for clinical application is also evaluated. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Magnetic Resonance in Medicine Wiley

Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan

Loading next page...
 
/lp/wiley/diffusion-weighting-by-the-trace-of-the-diffusion-tensor-within-a-BT5tf6Zg8h

References (31)

Publisher
Wiley
Copyright
Copyright © 1995 Wiley Subscription Services
ISSN
0740-3194
eISSN
1522-2594
DOI
10.1002/mrm.1910330107
Publisher site
See Article on Publisher Site

Abstract

The anisotropy of the water diffusion tensor inside brain causes contrast in diffusion images, which depends on the relative orientation of the diffusion gradients and the subject. Because the trace of a tensor is invariant upon rotation, measurement of this trace can reduce the orientation effect. A family of imaging pulse sequences is presented in which the signal intensity is weighted by the trace of the diffusion tensor in a single scan. The methods are demonstrated for chicken gizzard in several orientations with respect to the gradient frame of reference, and for ischemic injury in cat brain after middle cerebral artery occlusion. The sensitivity of the techniques to the presence of background gradients is measured and discussed in detail. As a result, pulse sequences are suggested that provide reliable diffusion constants in both homogeneous and inhomogeneous magnetic fields. The efficiency of the techniques for clinical application is also evaluated.

Journal

Magnetic Resonance in MedicineWiley

Published: Jan 1, 1995

Keywords: ; ; ;

There are no references for this article.