Determination of Buprenorphine in Human Plasma by Gas Chromatography-Positive Ion Chemical Ionization Mass Spectrometry and Liquid Chromatography-Tandem Mass Spectrometry

Determination of Buprenorphine in Human Plasma by Gas Chromatography-Positive Ion Chemical... Buprenorphine is used for the management of pain and has been advocated for the treatment of opioid addiction. Therapeutic doses result in low plasma concentrations of buprenorphine. In order to assess the safety and efficacy of buprenorphine, sensitive analytical methods are needed. Until recently, gas chromatography-positive ion chemical ionization mass spectrometry (GC-PCI-MS) offered the most sensitive method to selectively quantitate buprenorphine. We have developed and validated a sensitive liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS) method for buprenorphine. The method is described and compared with a GC-PCI-MS method validated in this laboratory. One-milliliter aliquots of plasma are required for the LC-ESI-MS-MS method and 2-mL aliquots for the GC-PCI-MS method. Buprenorphine-d4 is used as internal standard for both methods. Derivatization with pentafluoropropionic acid anhydride is used for the GC-PCI-MS method, in which the derivatized protonated molecular ions after loss of water are monitored at m/z 596 and 600. For LC-ESI-MS-MS, the parent protonated molecule ions are monitored at m/z 468 and 472. A single-step extraction of basic plasma with n-butyl chloride provided recoveries of 70–87%. Although a limit of quantitation (LOQ) of 0.1 ng/mL could be established for LC-ESI-MS-MS, we could only achieve an LOQ of 0.5 ng/mL with the GC-PCI-MS assay. The GC-PCI-MS method has a linear range of 0.5 to 40 ng/mL (mean r2 = 0.998, n = 7). For quality control samples at 1.0, 2.5, and 12.5 ng/mL, the intra- and interassay coefficients of variation (CV) did not exceed 14%, and percent of targets were within 16%. The LC-ESI-MS-MS method had a linear range of 0.1 to 10 ng/mL (mean r2 = 0.999, n = 7). http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Analytical Toxicology Oxford University Press

Determination of Buprenorphine in Human Plasma by Gas Chromatography-Positive Ion Chemical Ionization Mass Spectrometry and Liquid Chromatography-Tandem Mass Spectrometry

Loading next page...
 
/lp/oxford-university-press/determination-of-buprenorphine-in-human-plasma-by-gas-chromatography-0xTqpNT09Y

References (23)

Publisher
Oxford University Press
Copyright
© Published by Oxford University Press.
Subject
Articles
ISSN
0146-4760
eISSN
1945-2403
DOI
10.1093/jat/21.6.406
Publisher site
See Article on Publisher Site

Abstract

Buprenorphine is used for the management of pain and has been advocated for the treatment of opioid addiction. Therapeutic doses result in low plasma concentrations of buprenorphine. In order to assess the safety and efficacy of buprenorphine, sensitive analytical methods are needed. Until recently, gas chromatography-positive ion chemical ionization mass spectrometry (GC-PCI-MS) offered the most sensitive method to selectively quantitate buprenorphine. We have developed and validated a sensitive liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS) method for buprenorphine. The method is described and compared with a GC-PCI-MS method validated in this laboratory. One-milliliter aliquots of plasma are required for the LC-ESI-MS-MS method and 2-mL aliquots for the GC-PCI-MS method. Buprenorphine-d4 is used as internal standard for both methods. Derivatization with pentafluoropropionic acid anhydride is used for the GC-PCI-MS method, in which the derivatized protonated molecular ions after loss of water are monitored at m/z 596 and 600. For LC-ESI-MS-MS, the parent protonated molecule ions are monitored at m/z 468 and 472. A single-step extraction of basic plasma with n-butyl chloride provided recoveries of 70–87%. Although a limit of quantitation (LOQ) of 0.1 ng/mL could be established for LC-ESI-MS-MS, we could only achieve an LOQ of 0.5 ng/mL with the GC-PCI-MS assay. The GC-PCI-MS method has a linear range of 0.5 to 40 ng/mL (mean r2 = 0.998, n = 7). For quality control samples at 1.0, 2.5, and 12.5 ng/mL, the intra- and interassay coefficients of variation (CV) did not exceed 14%, and percent of targets were within 16%. The LC-ESI-MS-MS method had a linear range of 0.1 to 10 ng/mL (mean r2 = 0.999, n = 7).