Troubleshooting electromagnetic interference in a patient with centrifugal flow left ventricular assist device and subcutaneous implantable cardioverter defibrillator

Troubleshooting electromagnetic interference in a patient with centrifugal flow left ventricular... A 25‐year‐old man with severe nonischemic dilated cardiomyopathy underwent subcutaneous implantable cardioverter defibrillator (S‐ICD) implant and subsequently underwent HeartWare ventricular assist device (HVAD) placement. Postoperative interrogation revealed both primary and secondary S‐ICD vectors inappropriately regarded sinus rhythm as “noise,” and the alternate vector significantly undersensed sinus rhythm. The S‐ICD was reinterrogated using high‐resolution capture to visually confirm EMI with a dominant frequency in both the primary and secondary vectors of 46.67 Hz that fell within the S‐ICD operational range of 9–60 Hz. The 46.67 Hz frequency correlated with the HVAD operational speed of 2,800 RPM. The HVAD pump speed was increased from 2,800 to 3,000 RPM, resulting in a dominant frequency of 50 Hz. The notch filter is nonprogrammable in S‐ICDs. However, the built‐in filter is 50 Hz for countries in European time zones as opposed to 60 Hz in US time zones due to differences in the anticipated noise from electrical sources within each continent. Thus, the S‐ICD time zone was reprogrammed from EST to GMT, which reduced the notch filter from 60  to 50 Hz, resulting in S‐ICD successfully eliminating EMI when the patient was in a supine position. The EMI interference was still intermittently present in the upright patient position. This case demonstrates the utility of high‐resolution electrogram capture to identify the source and frequency of EMI in S‐ICD and offers a potential avenue to troubleshoot dominant frequency oversensing by changing the device time zone. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Cardiovascular Electrophysiology Wiley

Troubleshooting electromagnetic interference in a patient with centrifugal flow left ventricular assist device and subcutaneous implantable cardioverter defibrillator

Loading next page...
 
/lp/wiley/troubleshooting-electromagnetic-interference-in-a-patient-with-dlTgIZUbDj
Publisher
Wiley
Copyright
Journal compilation © 2018 Wiley Periodicals, Inc.
ISSN
1045-3873
eISSN
1540-8167
D.O.I.
10.1111/jce.13433
Publisher site
See Article on Publisher Site

Abstract

A 25‐year‐old man with severe nonischemic dilated cardiomyopathy underwent subcutaneous implantable cardioverter defibrillator (S‐ICD) implant and subsequently underwent HeartWare ventricular assist device (HVAD) placement. Postoperative interrogation revealed both primary and secondary S‐ICD vectors inappropriately regarded sinus rhythm as “noise,” and the alternate vector significantly undersensed sinus rhythm. The S‐ICD was reinterrogated using high‐resolution capture to visually confirm EMI with a dominant frequency in both the primary and secondary vectors of 46.67 Hz that fell within the S‐ICD operational range of 9–60 Hz. The 46.67 Hz frequency correlated with the HVAD operational speed of 2,800 RPM. The HVAD pump speed was increased from 2,800 to 3,000 RPM, resulting in a dominant frequency of 50 Hz. The notch filter is nonprogrammable in S‐ICDs. However, the built‐in filter is 50 Hz for countries in European time zones as opposed to 60 Hz in US time zones due to differences in the anticipated noise from electrical sources within each continent. Thus, the S‐ICD time zone was reprogrammed from EST to GMT, which reduced the notch filter from 60  to 50 Hz, resulting in S‐ICD successfully eliminating EMI when the patient was in a supine position. The EMI interference was still intermittently present in the upright patient position. This case demonstrates the utility of high‐resolution electrogram capture to identify the source and frequency of EMI in S‐ICD and offers a potential avenue to troubleshoot dominant frequency oversensing by changing the device time zone.

Journal

Journal of Cardiovascular ElectrophysiologyWiley

Published: Jan 1, 2018

Keywords: ; ;

References

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 18 million articles from more than
15,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Search

Query the DeepDyve database, plus search all of PubMed and Google Scholar seamlessly

Organize

Save any article or search result from DeepDyve, PubMed, and Google Scholar... all in one place.

Access

Get unlimited, online access to over 18 million full-text articles from more than 15,000 scientific journals.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve

Freelancer

DeepDyve

Pro

Price

FREE

$49/month
$360/year

Save searches from
Google Scholar,
PubMed

Create lists to
organize your research

Export lists, citations

Read DeepDyve articles

Abstract access only

Unlimited access to over
18 million full-text articles

Print

20 pages / month

PDF Discount

20% off