Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Percutaneous closure of tricuspid paravalvular leak without contrast for a patient with renal insufficiency

Percutaneous closure of tricuspid paravalvular leak without contrast for a patient with renal... Percutaneous endovascular devices have been used to close aorto‐pulmonary fistulas, aorto‐atrial fistulas, left ventricular pseudoaneurysms, and prosthetic valvular leaks (PVL). We present images of a percutaneous closure of a PVL from a bioprosthetic tricuspid valve in a patient with renal insufficiency without contrast.A 76‐year‐old female presented with atrial fibrillation, renal insufficiency, and progressive right heart failure, 12 years following 21‐mm aortic, 25‐mm mitral, and 31‐mm tricuspid valve replacements with Hancock bioprosthetic valves (Medtronic, Minneapolis, MN) for rheumatic heart disease. A transthoracic echocardiogram revealed a tricuspid bioprosthetic PVL near the ventricular septum measuring 4 × 7 mm with an estimated regurgitant volume of 24 mL (Figures A and B). The right ventricular ejection fraction was 37% and the pulmonary artery pressure was 72/26 mmHg. In view of her symptoms of right heart failure, severe renal insufficiency, and increased operative risk, the patient underwent percutaneous closure of the PVL without contrast medium.Pre‐procedure transthoracic echocardiogram. (A) Sizing the PVL. (B) Measuring the regurgitation over PVL. The white arrow indicates the PVL, while the colorful area indicates the regurgitation over the PVL. PVL, prosthetic valvular leakThe procedure was performed in the cath lab under local anesthesia. The baseline central venous pressure (CVP) was 34 mmHg. Transthoracic echocardiography and fluoroscopy http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Cardiac Surgery Wiley

Percutaneous closure of tricuspid paravalvular leak without contrast for a patient with renal insufficiency

Loading next page...
1
 
/lp/wiley/percutaneous-closure-of-tricuspid-paravalvular-leak-without-contrast-4afv021MEZ

References (8)

Publisher
Wiley
Copyright
"© 2018 Wiley Periodicals, Inc."
ISSN
0886-0440
eISSN
1540-8191
DOI
10.1111/jocs.13520
pmid
29464797
Publisher site
See Article on Publisher Site

Abstract

Percutaneous endovascular devices have been used to close aorto‐pulmonary fistulas, aorto‐atrial fistulas, left ventricular pseudoaneurysms, and prosthetic valvular leaks (PVL). We present images of a percutaneous closure of a PVL from a bioprosthetic tricuspid valve in a patient with renal insufficiency without contrast.A 76‐year‐old female presented with atrial fibrillation, renal insufficiency, and progressive right heart failure, 12 years following 21‐mm aortic, 25‐mm mitral, and 31‐mm tricuspid valve replacements with Hancock bioprosthetic valves (Medtronic, Minneapolis, MN) for rheumatic heart disease. A transthoracic echocardiogram revealed a tricuspid bioprosthetic PVL near the ventricular septum measuring 4 × 7 mm with an estimated regurgitant volume of 24 mL (Figures A and B). The right ventricular ejection fraction was 37% and the pulmonary artery pressure was 72/26 mmHg. In view of her symptoms of right heart failure, severe renal insufficiency, and increased operative risk, the patient underwent percutaneous closure of the PVL without contrast medium.Pre‐procedure transthoracic echocardiogram. (A) Sizing the PVL. (B) Measuring the regurgitation over PVL. The white arrow indicates the PVL, while the colorful area indicates the regurgitation over the PVL. PVL, prosthetic valvular leakThe procedure was performed in the cath lab under local anesthesia. The baseline central venous pressure (CVP) was 34 mmHg. Transthoracic echocardiography and fluoroscopy

Journal

Journal of Cardiac SurgeryWiley

Published: Feb 1, 2018