Access the full text.
Sign up today, get DeepDyve free for 14 days.
C. Ruiz, V. Jelnin, I. Kronzon, Y. Dudiy, R. Valle-Fernández, Bryce Einhorn, P. Chiam, C. Martinez, R. Eiros, G. Roubin, H. Cohen (2011)
Clinical outcomes in patients undergoing percutaneous closure of periprosthetic paravalvular leaks.Journal of the American College of Cardiology, 58 21
M. Alkhouli, Ahmed Almustafa, A. Kawsara, A. Tarabishy (2017)
Transcatheter closure of an aortoatrial fistula following a surgical aortic valve replacementJournal of Cardiac Surgery, 32
A. Alameddine, V. Alimov (2016)
Endovascular Closure of an Aortic Pseudoaneurysm Complicated by Aorto‐Pulmonary FistulaJournal of Cardiac Surgery, 31
Mariel Turner, W. Lai, J. Vincent (2013)
Percutaneous closure of tricuspid paravalvular leakCatheterization and Cardiovascular Interventions, 82
(2017)
Transcatheter closure of an aorto-atrial fistula following a surgical aortic valve replacement
(2017)
Percutaneous closure of LV pseudaneurysm caused by central venting cannula
M. Alkhouli, M. Hijazi, Tatiana Busu, Fahad Alqahtani, A. Tarabishy (2017)
Percutaneous closure of left ventricular pseudoaneurysm caused by a central venting cannulaJournal of Cardiac Surgery, 32
(2016)
Pseudoaneurysm complicated by aortopulmonary fistula
Percutaneous endovascular devices have been used to close aorto‐pulmonary fistulas, aorto‐atrial fistulas, left ventricular pseudoaneurysms, and prosthetic valvular leaks (PVL). We present images of a percutaneous closure of a PVL from a bioprosthetic tricuspid valve in a patient with renal insufficiency without contrast.A 76‐year‐old female presented with atrial fibrillation, renal insufficiency, and progressive right heart failure, 12 years following 21‐mm aortic, 25‐mm mitral, and 31‐mm tricuspid valve replacements with Hancock bioprosthetic valves (Medtronic, Minneapolis, MN) for rheumatic heart disease. A transthoracic echocardiogram revealed a tricuspid bioprosthetic PVL near the ventricular septum measuring 4 × 7 mm with an estimated regurgitant volume of 24 mL (Figures A and B). The right ventricular ejection fraction was 37% and the pulmonary artery pressure was 72/26 mmHg. In view of her symptoms of right heart failure, severe renal insufficiency, and increased operative risk, the patient underwent percutaneous closure of the PVL without contrast medium.Pre‐procedure transthoracic echocardiogram. (A) Sizing the PVL. (B) Measuring the regurgitation over PVL. The white arrow indicates the PVL, while the colorful area indicates the regurgitation over the PVL. PVL, prosthetic valvular leakThe procedure was performed in the cath lab under local anesthesia. The baseline central venous pressure (CVP) was 34 mmHg. Transthoracic echocardiography and fluoroscopy
Journal of Cardiac Surgery – Wiley
Published: Feb 1, 2018
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.