Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Diagnostic accuracy of periapical radiography and cone beam computed tomography in detecting apical periodontitis using histopathological findings as a reference standard

Diagnostic accuracy of periapical radiography and cone beam computed tomography in detecting... doi:10.1111/iej.12650 Diagnostic accuracy of periapical radiography and cone beam computed tomography in detecting apical periodontitis using histopathological findings as a reference standard 1 1 1 2 1,2 S. Kanagasingam , C. X. Lim , C. P. Yong , F. Mannocci & S. Patel Department of Operative Dentistry, Faculty of Dentistry, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia; and Department of Endodontology, King’s College Dental Institute, London, UK Abstract analysed using rater mean (n = 5). Receiver-operating characteristic (ROC) analysis was carried out. Kanagasingam S, Lim CX, Yong CP, Mannocci F, Results Sensitivity was 0.27, 0.38 and 0.89 for Patel S. Diagnostic accuracy of periapical radiography and DP, DPS and CBCT scans, respectively. CBCT had cone beam computed tomography in detecting apical specificity and positive predictive value of 1.0 whilst periodontitis using histopathological findings as a reference DP and DPS had specificity and positive predictive standard. International Endodontic Journal, 50, 417–426, 2017. value of 0.99. The negative predictive value was Aim To compare the diagnostic accuracy of periapi- 0.39, 0.44 and 0.81 for DP, DPS and CBCT scans, cal radiography (PR) and cone beam computed respectively. Area under the curve (AUC) for the var- tomography (CBCT) in detecting apical periodontitis ious http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png International Endodontic Journal Wiley

Diagnostic accuracy of periapical radiography and cone beam computed tomography in detecting apical periodontitis using histopathological findings as a reference standard

Loading next page...
 
/lp/wiley/diagnostic-accuracy-of-periapical-radiography-and-cone-beam-computed-BrX0Ly7cNT

References (64)

Publisher
Wiley
Copyright
Copyright © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd
ISSN
0143-2885
eISSN
1365-2591
DOI
10.1111/iej.12650
pmid
27063209
Publisher site
See Article on Publisher Site

Abstract

doi:10.1111/iej.12650 Diagnostic accuracy of periapical radiography and cone beam computed tomography in detecting apical periodontitis using histopathological findings as a reference standard 1 1 1 2 1,2 S. Kanagasingam , C. X. Lim , C. P. Yong , F. Mannocci & S. Patel Department of Operative Dentistry, Faculty of Dentistry, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia; and Department of Endodontology, King’s College Dental Institute, London, UK Abstract analysed using rater mean (n = 5). Receiver-operating characteristic (ROC) analysis was carried out. Kanagasingam S, Lim CX, Yong CP, Mannocci F, Results Sensitivity was 0.27, 0.38 and 0.89 for Patel S. Diagnostic accuracy of periapical radiography and DP, DPS and CBCT scans, respectively. CBCT had cone beam computed tomography in detecting apical specificity and positive predictive value of 1.0 whilst periodontitis using histopathological findings as a reference DP and DPS had specificity and positive predictive standard. International Endodontic Journal, 50, 417–426, 2017. value of 0.99. The negative predictive value was Aim To compare the diagnostic accuracy of periapi- 0.39, 0.44 and 0.81 for DP, DPS and CBCT scans, cal radiography (PR) and cone beam computed respectively. Area under the curve (AUC) for the var- tomography (CBCT) in detecting apical periodontitis ious

Journal

International Endodontic JournalWiley

Published: May 1, 2017

Keywords: ; ; ;

There are no references for this article.