Carotid inter‐adventitial diameter is more strongly related to plaque score than lumen diameter: An automated tool for stroke analysis

Carotid inter‐adventitial diameter is more strongly related to plaque score than lumen diameter:... ABSTRACT Purpose To compare the strength of correlation between automatically measured carotid lumen diameter (LD) and interadventitial diameter (IAD) with plaque score (PS). Methods Retrospective study on a database of 404 common carotid artery B‐mode sonographic images from 202 diabetic patients. LD and IAD were computed automatically using an advanced computerized edge detection method and compared with two distinct manual measurements. PS was computed by adding the maximal thickness in millimeters of plaques in segments taken from the internal carotid artery, bulb, and common carotid artery on both sides. Results The coefficient of correlation was 0.19 (p < 0.007) between LD and PS, and 0.25 (p < 0.0006) between IAD and PS. After excluding 10 outliers, coefficient of correlation was 0.25 (p < 0.0001) between LD and PS, and 0.38 (p < 0.0001) between IAD and PS. The precision of merit of automated versus the two manual measurements was 96.6% and 97.2% for LD, and 97.7% and 98.1%, for IAD, respectively. Conclusions Our automated measurement system gave satisfying results in comparison with manual measurements. Carotid IAD was more strongly correlated to PS than carotid LD in this population sample of Japanese diabetic patients. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 44:210–220, 2016 http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Clinical Ultrasound Wiley

Carotid inter‐adventitial diameter is more strongly related to plaque score than lumen diameter: An automated tool for stroke analysis

Loading next page...
 
/lp/wiley/carotid-inter-adventitial-diameter-is-more-strongly-related-to-plaque-NkQF3jFkGC

References (57)

Publisher
Wiley
Copyright
© 2016 Wiley Periodicals, Inc.
ISSN
0091-2751
eISSN
1097-0096
DOI
10.1002/jcu.22334
pmid
26887355
Publisher site
See Article on Publisher Site

Abstract

ABSTRACT Purpose To compare the strength of correlation between automatically measured carotid lumen diameter (LD) and interadventitial diameter (IAD) with plaque score (PS). Methods Retrospective study on a database of 404 common carotid artery B‐mode sonographic images from 202 diabetic patients. LD and IAD were computed automatically using an advanced computerized edge detection method and compared with two distinct manual measurements. PS was computed by adding the maximal thickness in millimeters of plaques in segments taken from the internal carotid artery, bulb, and common carotid artery on both sides. Results The coefficient of correlation was 0.19 (p < 0.007) between LD and PS, and 0.25 (p < 0.0006) between IAD and PS. After excluding 10 outliers, coefficient of correlation was 0.25 (p < 0.0001) between LD and PS, and 0.38 (p < 0.0001) between IAD and PS. The precision of merit of automated versus the two manual measurements was 96.6% and 97.2% for LD, and 97.7% and 98.1%, for IAD, respectively. Conclusions Our automated measurement system gave satisfying results in comparison with manual measurements. Carotid IAD was more strongly correlated to PS than carotid LD in this population sample of Japanese diabetic patients. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 44:210–220, 2016

Journal

Journal of Clinical UltrasoundWiley

Published: May 1, 2016

Keywords: ; ; ; ; ; ; ; ;