The spatial resolution of dual-tracer fluorescence thermometry in volumetrically illuminated channels

The spatial resolution of dual-tracer fluorescence thermometry in volumetrically illuminated... This study estimates the spatial resolution and accuracy of dual-tracer fluorescence thermometry (DFT) for measuring water temperature fields in channels where the entire channel is illuminated as is typical in microfluidics. Temperature fields are measured in heated laminar Poiseuille flow through a 1 mm2 channel. The working fluid, an aqueous solution of the temperature-sensitive fluorophores fluorescein (Fl) and sulforhodamine B (SrB), is volumetrically illuminated over the entire channel cross-section at a wavelength of 514 nm, and the temperature of the solution is estimated from images of the longer-wavelength fluorescence from Fl and SrB. These temperature data are compared with numerical simulations of the same flow where the heat transferred to the water is estimated from independent measurements of wall surface temperature to determine the accuracy and the spatial resolution of the DFT results. The results suggest that temperature measurements in the volumetrically illuminated channel are significantly corrupted by the fluorescence emissions from beyond the focal plane. A model based on the point spread function for an aberration-free lens is employed to estimate the effect of the background “noise,” i.e., the signal from beyond the object plane, on the accuracy of these DFT measurements. The results show that this background is about 30 times the signal from the focal plane. Further experiments where the channel is illuminated by a light sheet over about 40 % of the channel cross-section give estimates of the water temperature field that are on average within about 0.3 °C of the numerical predictions at an in-plane spatial resolution of 50 μm. The model is used to estimate the signal-to-background ratio for this case, as well as for a variety of commercially available microscope objectives. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Experiments in Fluids Springer Journals

The spatial resolution of dual-tracer fluorescence thermometry in volumetrically illuminated channels

Loading next page...
 
/lp/springer_journal/the-spatial-resolution-of-dual-tracer-fluorescence-thermometry-in-wH4MfSa7N7
Publisher
Springer Berlin Heidelberg
Copyright
Copyright © 2013 by Springer-Verlag Berlin Heidelberg
Subject
Engineering; Engineering Fluid Dynamics; Fluid- and Aerodynamics; Engineering Thermodynamics, Heat and Mass Transfer
ISSN
0723-4864
eISSN
1432-1114
D.O.I.
10.1007/s00348-013-1649-5
Publisher site
See Article on Publisher Site

Abstract

This study estimates the spatial resolution and accuracy of dual-tracer fluorescence thermometry (DFT) for measuring water temperature fields in channels where the entire channel is illuminated as is typical in microfluidics. Temperature fields are measured in heated laminar Poiseuille flow through a 1 mm2 channel. The working fluid, an aqueous solution of the temperature-sensitive fluorophores fluorescein (Fl) and sulforhodamine B (SrB), is volumetrically illuminated over the entire channel cross-section at a wavelength of 514 nm, and the temperature of the solution is estimated from images of the longer-wavelength fluorescence from Fl and SrB. These temperature data are compared with numerical simulations of the same flow where the heat transferred to the water is estimated from independent measurements of wall surface temperature to determine the accuracy and the spatial resolution of the DFT results. The results suggest that temperature measurements in the volumetrically illuminated channel are significantly corrupted by the fluorescence emissions from beyond the focal plane. A model based on the point spread function for an aberration-free lens is employed to estimate the effect of the background “noise,” i.e., the signal from beyond the object plane, on the accuracy of these DFT measurements. The results show that this background is about 30 times the signal from the focal plane. Further experiments where the channel is illuminated by a light sheet over about 40 % of the channel cross-section give estimates of the water temperature field that are on average within about 0.3 °C of the numerical predictions at an in-plane spatial resolution of 50 μm. The model is used to estimate the signal-to-background ratio for this case, as well as for a variety of commercially available microscope objectives.

Journal

Experiments in FluidsSpringer Journals

Published: Dec 24, 2013

References

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 18 million articles from more than
15,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Search

Query the DeepDyve database, plus search all of PubMed and Google Scholar seamlessly

Organize

Save any article or search result from DeepDyve, PubMed, and Google Scholar... all in one place.

Access

Get unlimited, online access to over 18 million full-text articles from more than 15,000 scientific journals.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve

Freelancer

DeepDyve

Pro

Price

FREE

$49/month
$360/year

Save searches from
Google Scholar,
PubMed

Create lists to
organize your research

Export lists, citations

Read DeepDyve articles

Abstract access only

Unlimited access to over
18 million full-text articles

Print

20 pages / month

PDF Discount

20% off