Study on the self-integration of a Rogowski coil used in the measurement of partial discharges pulses

Study on the self-integration of a Rogowski coil used in the measurement of partial discharges... The maintenance of high-voltage power systems requires the determination of the amplitude and waveforms of fast current pulses that commonly occur in electric equipment. These high-frequency pulses may arise from different sources being partial discharges one of the most important events measured to determine the insulation status of electrical assets. This paper is a step forward in the modelling of Rogowski coils, which are commonly used to measure these pulses. This study was performed by means of a simplified model based on lumped electrical parameters. The model was simulated in Simulink and validated by measuring partial discharges (PD) in two different electrical insulation systems. The validation corroborates that the electrical model can be used to study the time and frequency responses of Rogowski coils with different number of turns and dimensions to obtain a configuration that fits the needs of the designer concerning the type of pulses that she/he wishes to measure. The paper also hints that changing the geometric parameters of the coil can be determinant to simplify the integration of pulses, so the Rogowski coil can be used to measure other type of pulses with different frequency spectra, such as lightning strikes, electrical arcs and post-arc phenomena, switching operations of circuit breakers and gas-insulated switchgears and electromagnetic pulses in general. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Electrical Engineering (Archiv fur Elektrotechnik) Springer Journals

Study on the self-integration of a Rogowski coil used in the measurement of partial discharges pulses

Loading next page...
 
/lp/springer_journal/study-on-the-self-integration-of-a-rogowski-coil-used-in-the-AsGivaKCVj
Publisher
Springer Berlin Heidelberg
Copyright
Copyright © 2016 by Springer-Verlag Berlin Heidelberg
Subject
Engineering; Electrical Engineering; Power Electronics, Electrical Machines and Networks; Energy Economics
ISSN
0948-7921
eISSN
1432-0487
D.O.I.
10.1007/s00202-016-0456-4
Publisher site
See Article on Publisher Site

Abstract

The maintenance of high-voltage power systems requires the determination of the amplitude and waveforms of fast current pulses that commonly occur in electric equipment. These high-frequency pulses may arise from different sources being partial discharges one of the most important events measured to determine the insulation status of electrical assets. This paper is a step forward in the modelling of Rogowski coils, which are commonly used to measure these pulses. This study was performed by means of a simplified model based on lumped electrical parameters. The model was simulated in Simulink and validated by measuring partial discharges (PD) in two different electrical insulation systems. The validation corroborates that the electrical model can be used to study the time and frequency responses of Rogowski coils with different number of turns and dimensions to obtain a configuration that fits the needs of the designer concerning the type of pulses that she/he wishes to measure. The paper also hints that changing the geometric parameters of the coil can be determinant to simplify the integration of pulses, so the Rogowski coil can be used to measure other type of pulses with different frequency spectra, such as lightning strikes, electrical arcs and post-arc phenomena, switching operations of circuit breakers and gas-insulated switchgears and electromagnetic pulses in general.

Journal

Electrical Engineering (Archiv fur Elektrotechnik)Springer Journals

Published: Oct 13, 2016

References

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 12 million articles from more than
10,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Unlimited reading

Read as many articles as you need. Full articles with original layout, charts and figures. Read online, from anywhere.

Stay up to date

Keep up with your field with Personalized Recommendations and Follow Journals to get automatic updates.

Organize your research

It’s easy to organize your research with our built-in tools.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve Freelancer

DeepDyve Pro

Price
FREE
$49/month

$360/year
Save searches from Google Scholar, PubMed
Create lists to organize your research
Export lists, citations
Read DeepDyve articles
Abstract access only
Unlimited access to over
18 million full-text articles
Print
20 pages/month
PDF Discount
20% off