Point-of-care coagulation monitoring: first clinical experience using a paper-based lateral flow diagnosticdevice

Point-of-care coagulation monitoring: first clinical experience using a paper-based lateral flow... Vitamin K antagonists such as warfarin are the most widely used class of oral anticoagulants. Due to a narrow therapeutic window, patients on warfarin require regular monitoring. Self-testing using point-of-care (POC) diagnostic devices is available, but cost makes this monitoring method beyond reach for many. The main objective of this research was to assess the clinical utility of a low-cost, paper-based lateral flow POC diagnostic device developed for anticoagulation monitoring without the need for a separate electronic reader. Custom-fabricated lateral flow assay (LFA) test strips comprised of a glass fiber sample pad, a nitrocellulose analytical membrane, a cellulose wicking pad, and a plastic backing card were assembled in a plastic cassette. Healthy volunteers and patients on warfarin therapy were recruited for this prospective study. For each participant, a whole blood sample was collected via fingerstick to determine: (1) international normalized ratio (INR) using the CoaguChek® XS coagulometer, (2) hematocrit by centrifugation, and (3) red blood cell (RBC) travel distance on the experimental LFA device after 240 s using digital image analysis. RBC travel distance measured on the LFA device using blood samples obtained from warfarin patients positively correlated with increasing INR value and the LFA device had the capability to statistically distinguish between healthy volunteer INR values and those for patients groups with INR ≥ 2.6. From these data, it is predicted that this low-cost, paper-based LFA device can have clinical utility for identifying anticoagulated patients taking vitamin K antagonists who are outside of the desired therapeutic efficacy window. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Biomedical Microdevices Springer Journals

Point-of-care coagulation monitoring: first clinical experience using a paper-based lateral flow diagnosticdevice

Loading next page...
 
/lp/springer_journal/point-of-care-coagulation-monitoring-first-clinical-experience-using-a-2CC00rdcfr
Publisher
Springer US
Copyright
Copyright © 2017 by Springer Science+Business Media, LLC
Subject
Engineering; Biomedical Engineering; Biological and Medical Physics, Biophysics; Nanotechnology; Engineering Fluid Dynamics
ISSN
1387-2176
eISSN
1572-8781
D.O.I.
10.1007/s10544-017-0206-z
Publisher site
See Article on Publisher Site

Abstract

Vitamin K antagonists such as warfarin are the most widely used class of oral anticoagulants. Due to a narrow therapeutic window, patients on warfarin require regular monitoring. Self-testing using point-of-care (POC) diagnostic devices is available, but cost makes this monitoring method beyond reach for many. The main objective of this research was to assess the clinical utility of a low-cost, paper-based lateral flow POC diagnostic device developed for anticoagulation monitoring without the need for a separate electronic reader. Custom-fabricated lateral flow assay (LFA) test strips comprised of a glass fiber sample pad, a nitrocellulose analytical membrane, a cellulose wicking pad, and a plastic backing card were assembled in a plastic cassette. Healthy volunteers and patients on warfarin therapy were recruited for this prospective study. For each participant, a whole blood sample was collected via fingerstick to determine: (1) international normalized ratio (INR) using the CoaguChek® XS coagulometer, (2) hematocrit by centrifugation, and (3) red blood cell (RBC) travel distance on the experimental LFA device after 240 s using digital image analysis. RBC travel distance measured on the LFA device using blood samples obtained from warfarin patients positively correlated with increasing INR value and the LFA device had the capability to statistically distinguish between healthy volunteer INR values and those for patients groups with INR ≥ 2.6. From these data, it is predicted that this low-cost, paper-based LFA device can have clinical utility for identifying anticoagulated patients taking vitamin K antagonists who are outside of the desired therapeutic efficacy window.

Journal

Biomedical MicrodevicesSpringer Journals

Published: Jul 10, 2017

References

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 12 million articles from more than
10,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Unlimited reading

Read as many articles as you need. Full articles with original layout, charts and figures. Read online, from anywhere.

Stay up to date

Keep up with your field with Personalized Recommendations and Follow Journals to get automatic updates.

Organize your research

It’s easy to organize your research with our built-in tools.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve Freelancer

DeepDyve Pro

Price
FREE
$49/month

$360/year
Save searches from
Google Scholar,
PubMed
Create lists to
organize your research
Export lists, citations
Read DeepDyve articles
Abstract access only
Unlimited access to over
18 million full-text articles
Print
20 pages/month
PDF Discount
20% off