Access the full text.
Sign up today, get DeepDyve free for 14 days.
K. Brookshier, John Tarbell (1993)
Evaluation of a transparent blood analog fluid: aqueous xanthan gum/glycerin.Biorheology, 30 2
Z. Keshavarz-Motamed, Julio Garcia, E. Gaillard, Nima Maftoon, G. Labbio, G. Cloutier, L. Kadem (2014)
Effect of coarctation of the aorta and bicuspid aortic valve on flow dynamics and turbulence in the aorta using particle image velocimetryExperiments in Fluids, 55
G. Vlastos, D. Lerche, B. Koch, O. Samba, M. Pohl (1997)
The effect of parallel combined steady and oscillatory shear flows on blood and polymer solutionsRheologica Acta, 36
J. Baldwin, S. Deutsch, D. Geselowitz, J. Tarbell (1994)
LDA measurements of mean velocity and Reynolds stress fields within an artificial heart ventricle.Journal of biomechanical engineering, 116 2
Kinematic viscosity of two non-Newtonian fluids obtained by steady shear test at 20 and 30 °C
(1967)
Hemodynamic features of a double-leaflet prosthetic heart valve of new design
G. Thurston (1979)
Rheological parameters for the viscosity viscoelasticity and thixotropy of blood.Biorheology, 16 3
David Mann, John Tarbell (1990)
Flow of non-Newtonian blood analog fluids in rigid curved and straight artery models.Biorheology, 27 5
SUNG Ling, H. Atabek, Donald Fry, Dali Patel, JOSEPH Janicki (1968)
Application of Heated‐Film Velocity and Shear Probes to Hemodynamic StudiesCirculation Research, 23
Kunlun Bai, J. Katz (2014)
On the refractive index of sodium iodide solutions for index matching in PIVExperiments in Fluids, 55
Thomas Marx, Thomas Marx, Burton Baldwin, Burton Baldwin, C. Kittle, C. Kittle (1959)
A cardiovascular simulator for the evaluation of prosthetic aortic valves.The Journal of thoracic and cardiovascular surgery, 38
S. Burgmann, S. Große, Wolfgang Schröder, J. Roggenkamp, Sebastian Jansen, F. Gräf, M. Büsen (2009)
A refractive index-matched facility for fluid–structure interaction studies of pulsatile and oscillating flow in elastic vessels of adjustable complianceExperiments in Fluids, 47
J. Vétel, A. Garon, D. Pelletier (2009)
Lagrangian coherent structures in the human carotid artery bifurcationExperiments in Fluids, 46
M. Yousif, D. Holdsworth, T. Poepping (2011)
A blood-mimicking fluid for particle image velocimetry with silicone vascular modelsExperiments in Fluids, 50
(1995)
Evaluation of high polymer solutions as blood analog fluid
P. Geoghegan, N. Buchmann, N. Buchmann, C. Spence, S. Moore, M. Jermy (2012)
Fabrication of rigid and flexible refractive-index-matched flow phantoms for flow visualisation and optical flow measurementsExperiments in Fluids, 52
P. Sousa, F. Pinho, Monica Oliveira, M. Alves (2011)
Extensional flow of blood analog solutions in microfluidic devices.Biomicrofluidics, 5
R. Budwig (1994)
Refractive index matching methods for liquid flow investigationsExperiments in Fluids, 17
Jennifer Long, A. Ündar, K. Manning, S. Deutsch (2005)
Viscoelasticity of Pediatric Blood and its Implications for the Testing of a Pulsatile Pediatric Blood PumpASAIO Journal, 51
D. Quemada (1978)
Rheology of concentrated disperse systems II. A model for non-newtonian shear viscosity in steady flowsRheologica Acta, 17
(2007)
Particle image velocimetry measurements of blood flow in a modeled carotid artery bifurcation BT
A. Walker, C. Johnston, D. Rival (2013)
On the Characterization of a Non-Newtonian Blood Analog and Its Response to Pulsatile Flow Downstream of a Simplified StenosisAnnals of Biomedical Engineering, 42
Fjh Gijsen, Van Vosse, J. Janssen (1999)
The influence of the non-Newtonian properties of blood on the flow in large arteries: steady flow in a carotid bifurcation model.Journal of biomechanics, 32 6
Four commonly used refractive-index (RI)-matched Newtonian blood-analog fluids are reviewed, and different non-Newtonian blood-analogs, with RI of 1.372–1.495, are investigated. Sodium iodide (NaI), sodium thiocyanate (NaSCN) and potassium thiocyanate are used to adjust the RI of blood-analogs to that of test sections for minimizing optical distortions in particle image velocimetry data, and xanthan gum (XG) is added to the fluids to give them non-Newtonian properties (shear thinning and viscoelasticity). Our results support the general belief that adding NaI to Newtonian fluids matches the RI without changing the kinematic viscosity. However, in contrast to claims made in a few studies that did not measure rheology, our investigation revealed that adding NaI or NaSCN to XG-based non-Newtonian fluids changes the viscosity of the fluids considerably and reduces the shear-thinning property. Therefore, the RI of non-Newtonian blood-analog fluids with XG cannot be adjusted easily by varying the concentration of NaI or NaSCN and needs more careful rheological study.
Experiments in Fluids – Springer Journals
Published: May 21, 2016
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.