On improvement of PIV image interrogation near stationary interfaces In this paper the problem posed by interfaces when present in PIV measurements is addressed. Different image pre-processing, processing and post-processing methodologies with the intention to minimize the interface effects are discussed and assessed using Monte Carlo simulations. Image treatment prior to the correlation process is shown to be incapable of fully removing the effects of the intensity pedestal across the object edge. The inherent assumption of periodicity in the signal causes the FFT-based correlation technique to perform the worst when the correlation window contains a signal truncation. Instead, an extended version of the masking technique introduced by Ronneberger et al. (Proceedings of the 9th international symposium on applications of laser techniques to fluid mechanics, Lisbon, 1998) is able to minimize the interface-correlation, resolving only the particle displacement peak. Once the displacement vector is obtained, the geometric center of the interrogation area is not the correct placement. Instead, the centre of mass position allows an unbiased representation of the wall flow (Usera et al. in Proceedings of the 12th international symposium on applications of laser techniques to fluid mechanics, Lisbon, 2004). The aforementioned concepts have been implemented in an adaptive interrogation methodology (Theunissen et al. in Meas Sci Technol 18:275–287, 2007) where additionally non-isotropic resolution and re-orientation of the correlation windows is applied near the interface, maximizing the wall-normal spatial resolution. The increase in resolution and robustness are demonstrated by application to a set of experimental images of a flat-plate, subsonic, turbulent boundary layer and a hypersonic flow over a double compression ramp. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Experiments in Fluids Springer Journals

On improvement of PIV image interrogation near stationary interfaces

Loading next page...
 
/lp/springer_journal/on-improvement-of-piv-image-interrogation-near-stationary-interfaces-69geBibBQl
Publisher
Springer-Verlag
Copyright
Copyright © 2008 by Springer-Verlag
Subject
Engineering; Engineering Fluid Dynamics; Fluid- and Aerodynamics; Engineering Thermodynamics, Heat and Mass Transfer
ISSN
0723-4864
eISSN
1432-1114
D.O.I.
10.1007/s00348-008-0481-9
Publisher site
See Article on Publisher Site

Abstract

In this paper the problem posed by interfaces when present in PIV measurements is addressed. Different image pre-processing, processing and post-processing methodologies with the intention to minimize the interface effects are discussed and assessed using Monte Carlo simulations. Image treatment prior to the correlation process is shown to be incapable of fully removing the effects of the intensity pedestal across the object edge. The inherent assumption of periodicity in the signal causes the FFT-based correlation technique to perform the worst when the correlation window contains a signal truncation. Instead, an extended version of the masking technique introduced by Ronneberger et al. (Proceedings of the 9th international symposium on applications of laser techniques to fluid mechanics, Lisbon, 1998) is able to minimize the interface-correlation, resolving only the particle displacement peak. Once the displacement vector is obtained, the geometric center of the interrogation area is not the correct placement. Instead, the centre of mass position allows an unbiased representation of the wall flow (Usera et al. in Proceedings of the 12th international symposium on applications of laser techniques to fluid mechanics, Lisbon, 2004). The aforementioned concepts have been implemented in an adaptive interrogation methodology (Theunissen et al. in Meas Sci Technol 18:275–287, 2007) where additionally non-isotropic resolution and re-orientation of the correlation windows is applied near the interface, maximizing the wall-normal spatial resolution. The increase in resolution and robustness are demonstrated by application to a set of experimental images of a flat-plate, subsonic, turbulent boundary layer and a hypersonic flow over a double compression ramp.

Journal

Experiments in FluidsSpringer Journals

Published: Mar 9, 2008

References

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 18 million articles from more than
15,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Search

Query the DeepDyve database, plus search all of PubMed and Google Scholar seamlessly

Organize

Save any article or search result from DeepDyve, PubMed, and Google Scholar... all in one place.

Access

Get unlimited, online access to over 18 million full-text articles from more than 15,000 scientific journals.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve

Freelancer

DeepDyve

Pro

Price

FREE

$49/month
$360/year

Save searches from
Google Scholar,
PubMed

Create lists to
organize your research

Export lists, citations

Read DeepDyve articles

Abstract access only

Unlimited access to over
18 million full-text articles

Print

20 pages / month

PDF Discount

20% off