Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Improvement of cold-wire response for measurement of temperature dissipation

Improvement of cold-wire response for measurement of temperature dissipation This work aimed at improving fine-scale measurements using cold-wire anemometry. The dissipation ɛ θ of the temperature variance was measured on the axis of a heated turbulent round jet. The measurements were performed with a constant current anemometer (CCA) operating fine Pt–10%Rh wires at very low overheat. The CCA developed for this purpose allowed the use of the current injection method in order to estimate the time constant of the wire. In the first part of the paper, it is shown that the time constants obtained for two wire diameters −d=1.2 and d=0.58 μm – compare well with those measured at the same time using two other methods (laser excitation and pulsed wire). Moreover, for these two wires, the estimated time constants were in good agreement with those obtained from a semi-empirical relation. In the second part of the paper, a compensation procedure – post-processing filtering – was developed in order to improved the frequency response of the cold-wire probes. The measurements carried out on the axis of the jet (Re D =16 500, Re λ  ≃ 167) showed that the frequency response of the 1.2 μm wire was significantly improved. In fact, the spectral characteristics of the compensated signal obtained with the 1.2 μm wire compared fairly well with those from the 0.58 μm wire. Moreover, the results indicated that the compensation procedure must be applied when the cut-off frequency of the cold-wire f c is lower than two times the Kolmogorov frequency f K. In the case where f c ≃ 0.6f K, the compensation procedure can reduce the error in the estimate of ɛ θ by more than 20%. When f c ≃ 2f K, the effect of the compensation is reduced to about 5%. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Experiments in Fluids Springer Journals

Improvement of cold-wire response for measurement of temperature dissipation

Experiments in Fluids , Volume 31 (3) – Sep 5, 2001

Loading next page...
1
 
/lp/springer_journal/improvement-of-cold-wire-response-for-measurement-of-temperature-DymFmpM4nG

References (0)

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
Springer Journals
Copyright
Copyright © 2001 by Springer-Verlag Berlin Heidelberg
Subject
Engineering; Engineering Fluid Dynamics; Fluid- and Aerodynamics; Engineering Thermodynamics, Heat and Mass Transfer
ISSN
0723-4864
eISSN
1432-1114
DOI
10.1007/s003480100294
Publisher site
See Article on Publisher Site

Abstract

This work aimed at improving fine-scale measurements using cold-wire anemometry. The dissipation ɛ θ of the temperature variance was measured on the axis of a heated turbulent round jet. The measurements were performed with a constant current anemometer (CCA) operating fine Pt–10%Rh wires at very low overheat. The CCA developed for this purpose allowed the use of the current injection method in order to estimate the time constant of the wire. In the first part of the paper, it is shown that the time constants obtained for two wire diameters −d=1.2 and d=0.58 μm – compare well with those measured at the same time using two other methods (laser excitation and pulsed wire). Moreover, for these two wires, the estimated time constants were in good agreement with those obtained from a semi-empirical relation. In the second part of the paper, a compensation procedure – post-processing filtering – was developed in order to improved the frequency response of the cold-wire probes. The measurements carried out on the axis of the jet (Re D =16 500, Re λ  ≃ 167) showed that the frequency response of the 1.2 μm wire was significantly improved. In fact, the spectral characteristics of the compensated signal obtained with the 1.2 μm wire compared fairly well with those from the 0.58 μm wire. Moreover, the results indicated that the compensation procedure must be applied when the cut-off frequency of the cold-wire f c is lower than two times the Kolmogorov frequency f K. In the case where f c ≃ 0.6f K, the compensation procedure can reduce the error in the estimate of ɛ θ by more than 20%. When f c ≃ 2f K, the effect of the compensation is reduced to about 5%.

Journal

Experiments in FluidsSpringer Journals

Published: Sep 5, 2001

There are no references for this article.