Furnace endoscope—measuring fuel spray properties in hot and corrosive environments

Furnace endoscope—measuring fuel spray properties in hot and corrosive environments A furnace endoscope was developed to carry out in-furnace measurements of black liquor sprays in order to discover the initial velocity, opening angle and trajectory of the spray, and compare spray disintegration mechanisms and spray appearance with the ones measured in a spray chamber. An error analysis of the velocity measurement method was carried out, and the meaning of the optimum measurement distance from the optics to the observed object is discussed. Some details of the development process of the probe are also presented, especially the definition of the scale of the image and the cooling system of the protection tubes. The furnace endoscope can be used in difficult conditions, such as those found inside a chemical recovery boiler (~1,200°C and corrosive chemicals) with promising and accurate measurement results. The equipment has been tested in several furnaces. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Experiments in Fluids Springer Journals

Furnace endoscope—measuring fuel spray properties in hot and corrosive environments

Loading next page...
 
/lp/springer_journal/furnace-endoscope-measuring-fuel-spray-properties-in-hot-and-corrosive-iA9nJJ5fgd

References (12)

Publisher
Springer Journals
Copyright
Copyright © 2004 by Springer-Verlag
Subject
Engineering; Engineering Fluid Dynamics; Fluid- and Aerodynamics; Engineering Thermodynamics, Heat and Mass Transfer
ISSN
0723-4864
eISSN
1432-1114
DOI
10.1007/s00348-004-0884-1
Publisher site
See Article on Publisher Site

Abstract

A furnace endoscope was developed to carry out in-furnace measurements of black liquor sprays in order to discover the initial velocity, opening angle and trajectory of the spray, and compare spray disintegration mechanisms and spray appearance with the ones measured in a spray chamber. An error analysis of the velocity measurement method was carried out, and the meaning of the optimum measurement distance from the optics to the observed object is discussed. Some details of the development process of the probe are also presented, especially the definition of the scale of the image and the cooling system of the protection tubes. The furnace endoscope can be used in difficult conditions, such as those found inside a chemical recovery boiler (~1,200°C and corrosive chemicals) with promising and accurate measurement results. The equipment has been tested in several furnaces.

Journal

Experiments in FluidsSpringer Journals

Published: Oct 15, 2004

There are no references for this article.