Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in Transjugular Intrahepatic Portosystemic Stent Shunt (TIPSS) Placement

Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in... Cardiovasc Intervent Radiol (2018) 41:1035–1042 https://doi.org/10.1007/s00270-018-1877-4 CLINICAL INVESTIGATION VENOUS INTERVENTIONS Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in Transjugular Intrahepatic Portosystemic Stent Shunt (TIPSS) Placement 1 1 2 1 • • • • Georg Bo ¨ ning Willie M. Lu ¨ demann Julius Chapiro Martin Jonczyk 1 1 1 1 • • • Bernd Hamm Rolf W. Gu ¨ nther Bernhard Gebauer Florian Streitparth Received: 3 October 2017 / Accepted: 8 January 2018 / Published online: 14 March 2018 Springer Science+Business Media, LLC, part of Springer Nature and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE) 2018 Abstract Results The median number of puncture attempts (CBCT: Purpose The aim of this study was to evaluate the feasi- n = 2, US: n = 4, p = 0.249) and the mean puncture time bility of cone-beam computed tomography (CBCT)-based (CBCT: 32 ± 45 min, US: 36 ± 45 min, p = 0.515) were real-time 3-D guidance of TIPSS placement and its posi- not significantly different. There were furthermore no tioning compared to standard guiding methods. significant differences in the mean time needed for the total Materials and Methods In a prospective, randomized, TIPSS procedure http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png CardioVascular and Interventional Radiology Springer Journals

Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in Transjugular Intrahepatic Portosystemic Stent Shunt (TIPSS) Placement

Loading next page...
 
/lp/springer_journal/clinical-experience-with-real-time-3-d-guidance-based-on-c-arm-K0x3qEZ6hd

References (23)

Publisher
Springer Journals
Copyright
Copyright © 2018 by Springer Science+Business Media, LLC, part of Springer Nature and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE)
Subject
Medicine & Public Health; Imaging / Radiology; Cardiology; Nuclear Medicine; Ultrasound
ISSN
0174-1551
eISSN
1432-086X
DOI
10.1007/s00270-018-1877-4
pmid
29541837
Publisher site
See Article on Publisher Site

Abstract

Cardiovasc Intervent Radiol (2018) 41:1035–1042 https://doi.org/10.1007/s00270-018-1877-4 CLINICAL INVESTIGATION VENOUS INTERVENTIONS Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in Transjugular Intrahepatic Portosystemic Stent Shunt (TIPSS) Placement 1 1 2 1 • • • • Georg Bo ¨ ning Willie M. Lu ¨ demann Julius Chapiro Martin Jonczyk 1 1 1 1 • • • Bernd Hamm Rolf W. Gu ¨ nther Bernhard Gebauer Florian Streitparth Received: 3 October 2017 / Accepted: 8 January 2018 / Published online: 14 March 2018 Springer Science+Business Media, LLC, part of Springer Nature and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE) 2018 Abstract Results The median number of puncture attempts (CBCT: Purpose The aim of this study was to evaluate the feasi- n = 2, US: n = 4, p = 0.249) and the mean puncture time bility of cone-beam computed tomography (CBCT)-based (CBCT: 32 ± 45 min, US: 36 ± 45 min, p = 0.515) were real-time 3-D guidance of TIPSS placement and its posi- not significantly different. There were furthermore no tioning compared to standard guiding methods. significant differences in the mean time needed for the total Materials and Methods In a prospective, randomized, TIPSS procedure

Journal

CardioVascular and Interventional RadiologySpringer Journals

Published: Mar 14, 2018

There are no references for this article.