AUTHORS’ REPLY

AUTHORS’ REPLY the ESU and ABC are over 10 million particles per cubic foot. The data shown in Figure 1 should be considered to yield a relative qualitative comparison of the ESU and ABC since subsequent laboratory tests indicated that there was a loss of approximately 25% of the total number of particles in the relevant size ranges dure to particle set- tling and diffusion to the wall of the inlet probe of the op- tical particle counter. Since visibility is mainly related to smoke generation, the improvement with ABC is modest at best. However, higher argon flow rates tend to enhance visibility. In summary, the usefulness of ABC in plastic surgery seems limited because capillary and small-vessel bleeding as encountered in the liver is uncommon. The potential benefits weighed against the added inconvenience and ex- Fig. 1 Smoke particle concentrations vs. elapsed time of surgery pense do not seem worth the effort when compared to cur- rent standard electrosurgical units. The particulation pro- duced by the ESU and ABC are similar, and both units were measured eight feet from the point of smoke gener- present a potential health risk and nuisance associated ation. Previous studies have shown that smoke levels are with the smoke produced. It is also important to remem- essentially constant throughout the operating room except ber that ABC should not be utilized in patients with right for the transient fluctuations associated with the unsteady to left intracardiac shunts because of the rare but disas- flow field related to intermittent use of ESU or ABC. The trous consequences of gas embolism. present smoke data failed to demonstrate a significant dif- ference in particle density between ESU and ABC during V.L. Young ´ H.J. Brandon Washington University, St. Louis, Missouri, USA reduction mammoplasty. Peak particle densities for both Dr. Young is absolutely right in emphasizing the impor- pable of grabbing the vessel with pickups so that the sur- tance of not using the spray coagulation on larger vessels. geon can use the tip of the discussed ABC unit to apply This is in accordance with our own experience as reported current to these pickups and thus achieve ªconventionalº in the paper. However, we cannot follow the conclusion coagulation without having to switch instruments. We that the usefulness of ABC in plastic surgery is limited. think it is important to point out the different nature of Especially in procedures close to the body surface, bleed- the ABC devices routinely used for liver surgery that only ing from small vessels is commonly encountered and can use a plasma beam, as opposed to the device discussed easily and quickly be controlled by ABC. Although it is here. certainly necessary to use conventional coagulation when Finally we would like to thank Dr. Young for sharing encountering larger vessels while doing a reduction mam- his results concerning smoke particle densities with us. maplasty, we still feel that the use of the ABC is benefi- cial, since a lot of small bleeders can be controlled very W.G.N. Steinmetz ´ B.J. Bauer ´ P. Eckert effectively. However, it has to be admitted that in a teach- Plastic Surgery and Hand Surgery, University Hospital, ing hospital environment the assistant is usually quite ca- Josef-Schneider-Strasse 2, D-97078 Würzburg, Germany http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png European Journal of Plastic Surgery Springer Journals

AUTHORS’ REPLY

Free
1 page

Loading next page...
1 Page
1
 
/lp/springer_journal/authors-reply-Nj5v0gV8D0
Publisher
Springer Journals
Copyright
Copyright © 1998 by Springer-Verlag Berlin Heidelberg
Subject
Medicine & Public Health; Plastic Surgery
ISSN
0930-343X
eISSN
1435-0130
D.O.I.
10.1007/s002380050079
Publisher site
See Article on Publisher Site

Abstract

the ESU and ABC are over 10 million particles per cubic foot. The data shown in Figure 1 should be considered to yield a relative qualitative comparison of the ESU and ABC since subsequent laboratory tests indicated that there was a loss of approximately 25% of the total number of particles in the relevant size ranges dure to particle set- tling and diffusion to the wall of the inlet probe of the op- tical particle counter. Since visibility is mainly related to smoke generation, the improvement with ABC is modest at best. However, higher argon flow rates tend to enhance visibility. In summary, the usefulness of ABC in plastic surgery seems limited because capillary and small-vessel bleeding as encountered in the liver is uncommon. The potential benefits weighed against the added inconvenience and ex- Fig. 1 Smoke particle concentrations vs. elapsed time of surgery pense do not seem worth the effort when compared to cur- rent standard electrosurgical units. The particulation pro- duced by the ESU and ABC are similar, and both units were measured eight feet from the point of smoke gener- present a potential health risk and nuisance associated ation. Previous studies have shown that smoke levels are with the smoke produced. It is also important to remem- essentially constant throughout the operating room except ber that ABC should not be utilized in patients with right for the transient fluctuations associated with the unsteady to left intracardiac shunts because of the rare but disas- flow field related to intermittent use of ESU or ABC. The trous consequences of gas embolism. present smoke data failed to demonstrate a significant dif- ference in particle density between ESU and ABC during V.L. Young ´ H.J. Brandon Washington University, St. Louis, Missouri, USA reduction mammoplasty. Peak particle densities for both Dr. Young is absolutely right in emphasizing the impor- pable of grabbing the vessel with pickups so that the sur- tance of not using the spray coagulation on larger vessels. geon can use the tip of the discussed ABC unit to apply This is in accordance with our own experience as reported current to these pickups and thus achieve ªconventionalº in the paper. However, we cannot follow the conclusion coagulation without having to switch instruments. We that the usefulness of ABC in plastic surgery is limited. think it is important to point out the different nature of Especially in procedures close to the body surface, bleed- the ABC devices routinely used for liver surgery that only ing from small vessels is commonly encountered and can use a plasma beam, as opposed to the device discussed easily and quickly be controlled by ABC. Although it is here. certainly necessary to use conventional coagulation when Finally we would like to thank Dr. Young for sharing encountering larger vessels while doing a reduction mam- his results concerning smoke particle densities with us. maplasty, we still feel that the use of the ABC is benefi- cial, since a lot of small bleeders can be controlled very W.G.N. Steinmetz ´ B.J. Bauer ´ P. Eckert effectively. However, it has to be admitted that in a teach- Plastic Surgery and Hand Surgery, University Hospital, ing hospital environment the assistant is usually quite ca- Josef-Schneider-Strasse 2, D-97078 Würzburg, Germany

Journal

European Journal of Plastic SurgerySpringer Journals

Published: Jun 24, 1998

There are no references for this article.

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 18 million articles from more than
15,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Search

Query the DeepDyve database, plus search all of PubMed and Google Scholar seamlessly

Organize

Save any article or search result from DeepDyve, PubMed, and Google Scholar... all in one place.

Access

Get unlimited, online access to over 18 million full-text articles from more than 15,000 scientific journals.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve

Freelancer

DeepDyve

Pro

Price

FREE

$49/month
$360/year

Save searches from
Google Scholar,
PubMed

Create lists to
organize your research

Export lists, citations

Read DeepDyve articles

Abstract access only

Unlimited access to over
18 million full-text articles

Print

20 pages / month

PDF Discount

20% off