A practical approach for the optimization of channel integrity in the sealing of shallow microfluidic devices made from cyclic olefin polymer

A practical approach for the optimization of channel integrity in the sealing of shallow... A reduced channel height in microfluidic Lab-on-a-Chip (LOC) devices enables a reduction in the required volume of sample and reagents. LOC devices are most often manufactured by microstructuring a planar substrate and subsequently sealing it with a cover film. However, shallow chip designs, made from polymers, are sensitive to channel deformation during the sealing of the microfluidic device. Inappropriate bonding conditions often result in the loss of the microfluidic functionality. A systematic and practical approach for the identification of suitable bonding process parameters is missing. In this article, a straightforward approach for the optimization of channel integrity in the sealing of shallow microfluidic devices made from Cyclic Olefin Polymer (COP) is presented. Two COP materials were tested: COP Zeonex 690R (Glass transition temperature Tg = 135 °C) both as a cover film and substrate material, and COP ZF14 (Tg = 135 °C) as a film material. A mechanical analysis using microstructured Zeonex 690R substrates was performed to generate a matrix of low-distortion bonding parameters, including temperature, pressure and time. The well-established method of solvent-assisted bonding was used to enhance the characteristically low bond strengths of the native COP material. In addition, plasma-assisted bonding was tested and compared. The optimization approach was validated by the manufacture of a microfluidic test device, the demonstration of its microfluidic functionality, and the quantitative evaluation of the achieved channel integrity. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Biomedical Microdevices Springer Journals

A practical approach for the optimization of channel integrity in the sealing of shallow microfluidic devices made from cyclic olefin polymer

Loading next page...
 
/lp/springer_journal/a-practical-approach-for-the-optimization-of-channel-integrity-in-the-0jmNWe0nQN
Publisher
Springer US
Copyright
Copyright © 2018 by Springer Science+Business Media, LLC, part of Springer Nature
Subject
Engineering; Biomedical Engineering; Biological and Medical Physics, Biophysics; Nanotechnology; Engineering Fluid Dynamics
ISSN
1387-2176
eISSN
1572-8781
D.O.I.
10.1007/s10544-018-0265-9
Publisher site
See Article on Publisher Site

Abstract

A reduced channel height in microfluidic Lab-on-a-Chip (LOC) devices enables a reduction in the required volume of sample and reagents. LOC devices are most often manufactured by microstructuring a planar substrate and subsequently sealing it with a cover film. However, shallow chip designs, made from polymers, are sensitive to channel deformation during the sealing of the microfluidic device. Inappropriate bonding conditions often result in the loss of the microfluidic functionality. A systematic and practical approach for the identification of suitable bonding process parameters is missing. In this article, a straightforward approach for the optimization of channel integrity in the sealing of shallow microfluidic devices made from Cyclic Olefin Polymer (COP) is presented. Two COP materials were tested: COP Zeonex 690R (Glass transition temperature Tg = 135 °C) both as a cover film and substrate material, and COP ZF14 (Tg = 135 °C) as a film material. A mechanical analysis using microstructured Zeonex 690R substrates was performed to generate a matrix of low-distortion bonding parameters, including temperature, pressure and time. The well-established method of solvent-assisted bonding was used to enhance the characteristically low bond strengths of the native COP material. In addition, plasma-assisted bonding was tested and compared. The optimization approach was validated by the manufacture of a microfluidic test device, the demonstration of its microfluidic functionality, and the quantitative evaluation of the achieved channel integrity.

Journal

Biomedical MicrodevicesSpringer Journals

Published: Feb 24, 2018

References

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 18 million articles from more than
15,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Search

Query the DeepDyve database, plus search all of PubMed and Google Scholar seamlessly

Organize

Save any article or search result from DeepDyve, PubMed, and Google Scholar... all in one place.

Access

Get unlimited, online access to over 18 million full-text articles from more than 15,000 scientific journals.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve

Freelancer

DeepDyve

Pro

Price

FREE

$49/month
$360/year

Save searches from
Google Scholar,
PubMed

Create lists to
organize your research

Export lists, citations

Read DeepDyve articles

Abstract access only

Unlimited access to over
18 million full-text articles

Print

20 pages / month

PDF Discount

20% off