Access the full text.
Sign up today, get DeepDyve free for 14 days.
D. Figeys (2003)
Proteomics in 2002: a year of technical development and wide-ranging applications.Analytical chemistry, 75 12
V Mani, BV Chikkaveeraiah, V Patel, JS Gutkind, JF Rusling (2009)
Microfluidic electrochemical immunoassay for ultrasensitive detection of two cancer biomarker proteins in serumACS Nano, 3
Tianjun Yu, Wen Wang, Jinping Chen, Yi Zeng, Yingying Li, Guoqiang Yang, Yi Li (2012)
Dendrimer-Encapsulated Pt Nanoparticles: An Artificial Enzyme for Hydrogen ProductionJournal of Physical Chemistry C, 116
Suveen Kumar, Saurabh Kumar, S. Augustine, B. Malhotra (2017)
Protein functionalized nanostructured zirconia based electrochemical immunosensor for cardiac troponin I detectionJournal of Materials Research, 32
Zhibo Li (2017)
Fabrication of Electrochemical Immunosensor for Cardiac Biomarker Troponin I Determination and Its Potential for Acute Myocardial Infarction DiagnosisInternational Journal of Electrochemical Science
J. Wang, A. Ibáñez, M. Chatrathi, A. Escarpa (2001)
Electrochemical enzyme immunoassays on microchip platforms.Analytical chemistry, 73 21
F. Apple, A. Falahati, P. Paulsen, Elizabeth Miller, S. Sharkey (1997)
Improved detection of minor ischemic myocardial injury with measurement of serum cardiac troponin I.Clinical chemistry, 43 11
Fang Li, Yuqi Yu, H. Cui, Di Yang, Zhi-ping Bian (2013)
Label-free electrochemiluminescence immunosensor for cardiac troponin I using luminol functionalized gold nanoparticles as a sensing platform.The Analyst, 138 6
S. Ko, Bumjun Kim, Seongjae Jo, S. Oh, J. Park (2007)
Electrochemical detection of cardiac troponin I using a microchip with the surface-functionalized poly(dimethylsiloxane) channel.Biosensors & bioelectronics, 23 1
Chenyi Hu, Da-Peng Yang, Zhihua Wang, P. Huang, Xiansong Wang, Di Chen, D. Cui, Mo Yang, Nengqin Jia (2013)
Bio-mimetically synthesized Ag@BSA microspheres as a novel electrochemical biosensing interface for sensitive detection of tumor cells.Biosensors & bioelectronics, 41
Yoon, Kim (2000)
Multilayered assembly of dendrimers with enzymes on gold: thickness-controlled biosensing interfaceAnalytical chemistry, 72 5
H. Kitano (2002)
Systems Biology: A Brief OverviewScience, 295
A. Ahammad, Yo-Han Choi, K. Koh, Jae-Ho Kim, Jae‐Joon Lee, Minsu Lee (2011)
Electrochemical Detection of Cardiac Biomarker Troponin I at Gold Nanoparticle-Modified ITO Electrode by Using Open Circuit PotentialInternational Journal of Electrochemical Science
Tae Kim, S. Oh, Soonchul Hong, Young-Joon Mok, E. Choi (2014)
Point‐of‐Care Fluorescence Immunoassay for Cardiac Panel BiomarkersJournal of Clinical Laboratory Analysis, 28
S. Bas, H. Gülce, S. Yıldız, A. Gülce (2011)
Amperometric biosensors based on deposition of gold and platinum nanoparticles on polyvinylferrocene modified electrode for xanthine detection.Talanta, 87
A. Shumkov, E. Suprun, S. Shatinina, A. Lisitsa, V. Shumyantseva, A. Archakov (2013)
Gold and Silver Nanoparticles for Electrochemical Detection of Cardiac Troponin I Based on Stripping VoltammetryBioNanoScience, 3
Nandhinee Shanmugam, S. Muthukumar, Shajee Chaudhry, J. Anguiano, S. Prasad (2017)
Ultrasensitive nanostructure sensor arrays on flexible substrates for multiplexed and simultaneous electrochemical detection of a panel of cardiac biomarkers.Biosensors & bioelectronics, 89 Pt 2
M. Boujtita, M. Chapleau, N. Murr (1996)
Biosensors for analysis of ethanol in food: effect of the pasting liquidAnalytica Chimica Acta, 319
Rajesh, Vikas Sharma, N. Puri, A. Mulchandani, R. Kotnala (2016)
High performance dendrimer functionalized single-walled carbon nanotubes field effect transistor biosensor for protein detectionApplied Physics Letters, 109
S. North, E. Lock, C. Taitt, S. Walton (2010)
Critical aspects of biointerface design and their impact on biosensor developmentAnalytical and Bioanalytical Chemistry, 397
J. Ho, Yeh-Chun Lin, Li-sheng Wang, K. Hwang, P. Chou (2009)
Carbon nanoparticle-enhanced immunoelectrochemical detection for protein tumor marker with cadmium sulfide biotracers.Analytical chemistry, 81 4
M. Diware, H. Cho, W. Chegal, Y. Cho, Dong Kim, Sang O, Kyeong-Suk Kim, S. Paek (2017)
Ultrasensitive, label-free detection of cardiac biomarkers with optical SIS sensor.Biosensors & bioelectronics, 87
Chengbin Liu, Hang Zhang, Yanhong Tang, S. Luo (2014)
Controllable growth of graphene/Cu composite and its nanoarchitecture-dependent electrocatalytic activity to hydrazine oxidationJournal of Materials Chemistry, 2
Vigneshwaran Mani, B. Chikkaveeraiah, V. Patel, J. Gutkind, J. Rusling (2009)
Ultrasensitive immunosensor for cancer biomarker proteins using gold nanoparticle film electrodes and multienzyme-particle amplification.ACS nano, 3 3
D. Langhus (2002)
Fundamentals of Electroanalytical Chemistry (Monk, Paul M. S.)Journal of Chemical Education, 79
Mingqi Zhao, R. Crooks (1999)
Homogeneous Hydrogenation Catalysis with Monodisperse, Dendrimer-Encapsulated Pd and Pt Nanoparticles.Angewandte Chemie, 38 3
M. Negahdary, M. Behjati-Ardakani, N. Sattarahmady, H. Yadegari, H. Heli (2017)
Electrochemical aptasensing of human cardiac troponin I based on an array of gold nanodumbbells-Applied to early detection of myocardial infarctionSensors and Actuators B-chemical, 252
Guodong Liang, Shufeng Liu, Guizheng Zou, Xiaoli Zhang (2012)
Ultrasensitive immunoassay based on anodic near-infrared electrochemiluminescence from dual-stabilizer-capped CdTe nanocrystals.Analytical chemistry, 84 24
Dajie Lin, Jie Wu, Min Wang, Feng Yan, H. Ju (2012)
Triple signal amplification of graphene film, polybead carried gold nanoparticles as tracing tag and silver deposition for ultrasensitive electrochemical immunosensing.Analytical chemistry, 84 8
J. Koehne, A. Periyakaruppan, R. Gandhiraman, M. Meyyappan (2013)
Label-free detection of cardiac troponin-I using carbon nanofiber based nanoelectrode arrays.Analytical chemistry, 85 8
Federica Rusmini, Z. Zhong, J. Feijen (2007)
Protein immobilization strategies for protein biochips.Biomacromolecules, 8 6
Dongxia Liu, Jinxin Gao, C. Murphy, C. Williams (2004)
In situ attenuated total reflection infrared spectroscopy of dendrimer-stabilized platinum nanoparticles adsorbed on aluminaJournal of Physical Chemistry B, 108
(2014)
The detection of cTnI by the aptamer biosensor
Innam Lee, Xiliang Luo, Jiyong Huang, X. Cui, M. Yun (2012)
Detection of Cardiac Biomarkers Using Single Polyaniline Nanowire-Based Conductometric BiosensorsBiosensors, 2
M. Hasanzadeh, N. Shadjou, M. Eskandani, Jafar Soleymani, Farshad Jafari, M. Guardia (2014)
Dendrimer-encapsulated and cored metal nanoparticles for electrochemical nanobiosensingTrends in Analytical Chemistry, 53
G. Marko‐Varga, K. Johansson, L. Gorton (1994)
Enzyme-based biosensor as a selective detection unit in column liquid chromatography.Journal of chromatography. A, 660 1-2
B. Chikkaveeraiah, Vigneshwaran Mani, V. Patel, J. Gutkind, J. Rusling, J. Rusling, J. Rusling (2011)
Microfluidic electrochemical immunoarray for ultrasensitive detection of two cancer biomarker proteins in serum.Biosensors & bioelectronics, 26 11
O. Arotiba, Joseph Owino, P. Baker, E. Iwuoha (2010)
Electrochemical impedimetry of electrodeposited poly(propylene imine) dendrimer monolayerJournal of Electroanalytical Chemistry, 638
We report the fabrication of polyamidoamine (PAMAM) dendrimer with 128 carboxyl group-encapsulated Pt nanoparticle-modified screen-printed carbon electrode, as an impedimetric biosensor, for the quantitative detection of human cardiac biomarker troponin-I (cTnI). PAMAM-Pt was electrochemically deposited over SPCE and its 128 terminal carboxyl groups were used as anchors for the site-specific biomolecular immobilization of protein antibody, anti-cTnI. The biosensor was characterized by contact angle measurements, transmission electron microscopy, UV-visible spectroscopy, and electrochemical techniques. A single-frequency impedance analysis study was utilized for the biomolecular sensing by monitoring the changes in the phase angle obtained at an optimized frequency resulting from antigen-antibody interactions. An optimized frequency of 100 Hz was obtained at which maximum changes in the phase angle were observed after immunoreactions for a given concentration of analyte. A concentration-dependent increase in the phase angle of the biosensor was observed with increasing cTnI concentration in the range of 1 pg mL−1 to 100 ng mL−1. Based on the concentration response data, the dissociation constant was found to be 0.51 pM reflecting high affinity of biosensor towards cTnI analyte arising due to high anti-cTnI loading with a better probe orientation on the 3-dimensional PAMAM-Pt structure.
Journal of Solid State Electrochemistry – Springer Journals
Published: May 7, 2018
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.