Access the full text.
Sign up today, get DeepDyve free for 14 days.
Swati Sondhi, Y. Hote (2014)
Fractional order PID controller for load frequency controlEnergy Conversion and Management, 85
K. Diethelm, N. Ford, A. Freed (2013)
A Predictor-Corrector Approach for the Numerical Solution of Fractional Differential EquationsNonlinear Dynamics, 29
C. Hwang, Jeng-Fan Leu, S. Tsay (2002)
A note on time-domain simulation of feedback fractional-order systemsIEEE Trans. Autom. Control., 47
Salim Chennai, M. Benchouia (2014)
Unified power quality conditioner based on a three-level NPC inverter using fuzzy control techniques for all voltage disturbances compensationFrontiers in Energy, 8
S. Srinath, C. Kumar, M. Selvan (2014)
A simple digital control algorithm for three phase shunt active filter: simulation and experimentationFrontiers in Energy, 8
A. Benaissa, B. Rabhi, M. Benkhoris, A. Moussi, J. Claire (2012)
Fuzzy logic controller for five-level shunt active power filter under distorted voltage conditionsIECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
T. Poinot, J. Trigeassou (2003)
A method for modelling and simulation of fractional systemsSignal Process., 83
(2011)
Utility-current feed forward-based control for a singlephase active power filter
H. Afghoul, F. Krim, D. Chikouche, A. Beddar, K. Djazia (2013)
Fractional direct power control for active filter2013 IEEE 7th International Power Engineering and Optimization Conference (PEOCO)
J. Matas, L. Vicuna, J. Miret, Josep Guerrero, M. Castilla (2008)
Feedback Linearization of a Single-Phase Active Power Filter via Sliding Mode ControlIEEE Transactions on Power Electronics, 23
S. Taher, Masoud Fini, Saber Aliabadi (2014)
Fractional order PID controller design for LFC in electric power systems using imperialist competitive algorithmAin Shams Engineering Journal, 5
J. Heerdt, D. Coutinho, S. Mussa, M. Heldwein (2014)
Control Strategy for Current Harmonic Programmed AC Active Electronic Power LoadsIEEE Transactions on Industrial Electronics, 61
Hongsheng Li, Ying Luo, Y. Chen (2010)
A Fractional Order Proportional and Derivative (FOPD) Motion Controller: Tuning Rule and ExperimentsIEEE Transactions on Control Systems Technology, 18
L. Limongi, L. Filho, Luiz Genu, F. Bradaschia, M. Cavalcanti (2015)
Transformerless Hybrid Power Filter Based on a Six-Switch Two-Leg Inverter for Improved Harmonic Compensation PerformanceIEEE Transactions on Industrial Electronics, 62
Zhihuan Chen, Xiaohui Yuan, Bin Ji, Pengtao Wang, Hao Tian (2014)
Design of a fractional order PID controller for hydraulic turbine regulating system using chaotic non-dominated sorting genetic algorithm IIEnergy Conversion and Management, 84
I. Podlubny (1999)
Fractional-order systems and PIλDμ-controllersIEEE Trans. Autom. Control., 44
B Rabhi A Benaissa (2014)
Power quality improvement using fuzzy logic controller for five-level shunt active power filter under distorted voltage conditionsFrontiers in Energy, 8
S. Rahmani, A. Hamadi, K. Al-haddad, L. Dessaint (2014)
A Combination of Shunt Hybrid Power Filter and Thyristor-Controlled Reactor for Power QualityIEEE Transactions on Industrial Electronics, 61
A Beddar (2013)
Fractional direct power control for active filterProceedings of IEEE 7th International Power Engineering and Optimization Conference; citation_publication_date=2013; citation_pages=228-233; citation_id=CR2; citation_author=H Afghoul; citation_author=F Krim; citation_author=D Chikouche; citation_author=A Beddar; citation_publisher=Langkawi
A. Oustaloup, B. Mathieu, P. Lanusse (1995)
The CRONE Control of Resonant Plants: Application to a Flexible TransmissionEur. J. Control, 1
(1995)
Non-integer Derivation
R. Ribeiro, T. Rocha, R. Sousa, E. Santos, Antonio Lima (2015)
A Robust DC-Link Voltage Control Strategy to Enhance the Performance of Shunt Active Power Filters Without Harmonic Detection SchemesIEEE Trans. Ind. Electron., 62
Abstract A novel controller is proposed to regulate the DC-link voltage of a single phase active power filter (SPAPF). The proposed switched fractional controller (SFC) consists of a conventional PI controller, a fractional order PI (FO-PI) controller and a decision maker that switches between them. Commonly, the conventional PI controller is used in regulation loops due to its advantages in steady-state but it is limited in transient state. On the other hand, the FO-PI controller overcomes these drawbacks but it causes dramatic degradation in control performances in steady-state because of the fractional calculus theory and the approximation method used to implement this kind of controller. Thus, the purpose of this paper is to switch to the PI controller in steady-state to obtain the best power quality and to switch to the FO-PI controller when external disturbances are detected to guarantee a fast transient state. To investigate the efficiency and accuracy of the SFC considering all robustness tests, an experimental setup has been established. The results of the SFC fulfill the requirements, confirm its high performances in steady and transient states and demonstrate its feasibility and effectiveness. The experiment results have satisfied the limit specified by the IEEE harmonic standard 519.
"Frontiers in Energy" – Springer Journals
Published: Jun 1, 2016
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.