Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Potential applications of three-dimensional ultrasound in the pediatric urinary tract: pictorial demonstration based on preliminary results

Potential applications of three-dimensional ultrasound in the pediatric urinary tract: pictorial... The aim of this study was to describe the potential of three-dimensional ultrasound (3DUS) in the urinary tract of neonates, infants, and children. The potential applications are illustrated based on our experience in 80 patients using two different 3DUS techniques. Various disease entities throughout the neonatal and pediatric age have been evaluated. The potential of 3DUS is discussed based on comparison with conventional 2DUS or other imaging (as clinically indicated), focused on the potentially improved renal parenchymal volume assessment. In our experience, 3DUS is feasible in neonates, infants, and children without sedation. It reduces imaging time, improves demonstration of complex anatomy and allows for evaluation of anatomy/pathology in any plane. The 3DUS improves volume assessment and follow-up comparison by offering an improved standardization and documentation. Rendered views of the dilated collecting system enable a comprehensive demonstration of hydronephrosis similar to intravenous urography or MR urography images. Additionally, 3DUS offers an ideal tool for training and education. Yet, limitations have to be acknowledged: areas inaccessible for 2DUS; poor quality of the original 2DUS acquisition; limited resolution; patient motion and breathing; cardiac pulsation creating artifacts and misregistration; equipment cost; lack of 3D DICOM standards creating problems with data storage; as well as system-inherent technical limitations. Nevertheless, the 3DUS holds the potential to become a valuable additional imaging tool for sonographic evaluation of the pediatric urinary tract. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png European Radiology Springer Journals

Potential applications of three-dimensional ultrasound in the pediatric urinary tract: pictorial demonstration based on preliminary results

European Radiology , Volume 13 (12) – Oct 3, 2003

Loading next page...
 
/lp/springer-journals/potential-applications-of-three-dimensional-ultrasound-in-the-p8asR5JMl4

References (35)

Publisher
Springer Journals
Copyright
Copyright © 2003 by Springer-Verlag
Subject
Medicine & Public Health; Imaging / Radiology; Diagnostic Radiology; Interventional Radiology; Neuroradiology; Ultrasound; Internal Medicine
ISSN
0938-7994
eISSN
1432-1084
DOI
10.1007/s00330-003-2075-5
pmid
14531007
Publisher site
See Article on Publisher Site

Abstract

The aim of this study was to describe the potential of three-dimensional ultrasound (3DUS) in the urinary tract of neonates, infants, and children. The potential applications are illustrated based on our experience in 80 patients using two different 3DUS techniques. Various disease entities throughout the neonatal and pediatric age have been evaluated. The potential of 3DUS is discussed based on comparison with conventional 2DUS or other imaging (as clinically indicated), focused on the potentially improved renal parenchymal volume assessment. In our experience, 3DUS is feasible in neonates, infants, and children without sedation. It reduces imaging time, improves demonstration of complex anatomy and allows for evaluation of anatomy/pathology in any plane. The 3DUS improves volume assessment and follow-up comparison by offering an improved standardization and documentation. Rendered views of the dilated collecting system enable a comprehensive demonstration of hydronephrosis similar to intravenous urography or MR urography images. Additionally, 3DUS offers an ideal tool for training and education. Yet, limitations have to be acknowledged: areas inaccessible for 2DUS; poor quality of the original 2DUS acquisition; limited resolution; patient motion and breathing; cardiac pulsation creating artifacts and misregistration; equipment cost; lack of 3D DICOM standards creating problems with data storage; as well as system-inherent technical limitations. Nevertheless, the 3DUS holds the potential to become a valuable additional imaging tool for sonographic evaluation of the pediatric urinary tract.

Journal

European RadiologySpringer Journals

Published: Oct 3, 2003

There are no references for this article.