Access the full text.
Sign up today, get DeepDyve free for 14 days.
S Gunda (2015)
Initial real world experience with a novel insertable (Reveal LinQ@Medtronic) compared to the conventional (Reveal XT@Medtronic) implantable loop recorder at a tertiary care center – Points to ponder!Int J Cardiol, 191
H Kamel (2014)
Heart rhythm monitoring for evaluation of cryptogenic strokeN Engl J Med, 370
WC Choe (2015)
Comparison of Atrial Fibrillation Monitoring Strategies After Cryptogenic Stroke (from the Cryptogenic Stroke and Underlying AF Trial)Am J Cardiol, 16
N Dagres (2010)
Influence of the duration of Holter monitoring on the detection of arrhythmia recurrences after catheter ablation of atrial fibrillation: implications for patient follow-upInt J Cardiol, 139
S Joshi (2009)
Prevalence, predictors, and prognosis of atrial fibrillation early after pulmonary vein isolation: findings from 3 months of continuous automatic ECG loop recordingsJ Cardiovasc Electrophysiol, 20
C Eitel (2011)
Performance of an implantable automatic atrial fibrillation detection device: impact of software adjustments and relevance of manual episode analysisEuropace, 13
P Sanders (2016)
Performance of a new atrial fibrillation detection algorithm in a miniaturized insertable cardiac monitor: Results from the Reveal LINQ Usability StudyHeart Rhythm, 13
SZ Rosero (2013)
Ambulatory ECG monitoring in atrial fibrillation managementProg Cardiovasc Dis, 56
F Schlingloff (2013)
Implantable loop recorders after atrial ablation: patient compliance and data surveillance in clinical practiceInnovations, 8
Q Xiong (2015)
Asymptomatic versus symptomatic atrial fibrillation: A systematic review of age/gender differences and cardiovascular outcomesInt J Cardiol, 191
WN Kernan (2014)
Guidelines for the prevention of stroke in patients with stroke and transient ischemic attack: a guideline for healthcare professionals from the American Heart Association/American Stroke AssociationStroke, 45
S Mittal (2015)
Safety Profile of a Miniaturized Insertable Cardiac Monitor: Results from Two Prospective TrialsPacing Clin Electrophysiol, 38
VN Thijs (2016)
Predictors for atrial fibrillation detection after cryptogenic stroke: Results from CRYSTAL AFNeurology, 86
CW Israel (2004)
Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device: implications for optimal patient careJ Am Coll Cardiol, 43
AJ Camm (2010)
Guidelines for the management of atrial fibrillation: the Task Force for the Management of Atrial Fibrillation of the European Society of Cardiology (ESC)Europace, 12
DJ Gladstone (2014)
Atrial fibrillation in patients with cryptogenic strokeN Engl J Med, 370
S Pecha (2015)
Implantable loop recorder monitoring after concomitant surgical ablation for atrial fibrillation (AF): insights from more than 200 continuously monitored patientsHeart Vessels, 31
RJ Damiano (2016)
Detection of Atrial Fibrillation After Surgical Ablation: Conventional Versus Continuous MonitoringAnn Thorac Surg, 101
G Hindricks (2005)
Perception of atrial fibrillation before and after radiofrequency catheter ablation: relevance of asymptomatic arrhythmia recurrenceCirculation, 112
E Sciaraffia (2014)
Use of event recorders and loop recorders in clinical practice: results of the European Heart Rhythm Association SurveyEuropace, 6
G Hindricks (2010)
Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: Results of the XPECT trialCirc Arrhythm Electrophysiol, 3
P Kirchhof (2016)
A roadmap to improve the quality of atrial fibrillation management: proceedings from the fifth Atrial Fibrillation Network/European Heart Rhythm Association consensus conferenceEuropace, 18
CD Swerdlow (2000)
Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF InvestigatorsCirculation, 101
H Calkins (2012)
2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial designEuropace, 14
S Podd (2016)
Are implantable cardiac monitors the ‘gold standard’ for atrial fibrillation detection? A prospective randomized trial comparing atrial fibrillation monitoring using implantable cardiac monitors and DDDRP permanent pacemakers in post atrial fibrillation ablation patientsEuropace, 18
LM Christensen (2014)
Paroxysmal atrial fibrillation occurs often in cryptogenic ischaemic stroke. Final results from the SURPRISE studyEur J Neurol, 21
Schwerpunkt Herzschr Elektrophys 2016 · 27:355–359 K. Fikenzer ·N.Dagres · G. Hindricks DOI 10.1007/s00399-016-0471-1 Abt. für Rhythmologie, Herzzentrum Leipzig-Universitätsklinik, Klinik für Innere Medizin/Kardiologie, Eingegangen: 16. August 2016 Leipzig, Deutschland Angenommen: 26. August 2016 Online publiziert: 10. November 2016 © Springer-Verlag Berlin Heidelberg 2016 Implantierbare Loop-Rekorder bei Vorhofflimmern und nach Katheterablation Implantierbare Loop-Rekorder (ILR) mit ren, die sich hinsichtlich ihrer Sensitivi- Vorteil ist die Möglichkeit des Monito- derMöglichkeit zurDetektion von Vor- tät und ihrer Invasivität unterscheiden rings über eine Dauer von 2 bis 3 Jahren hofflimmern können zur Diagnose und (. Abb. 1). Je länger und engmaschiger und die Option, sowohl patientenakti- zum Monitoring von Vorhofflimmern ein solches Monitoring erfolgt, desto vierte als auch automatisch aktivierte eingesetzt werden. Nicht alle Patienten höher ist auch die Detektionsrate. Episoden aufzuzeichnen. sind unter dem Vorhofflimmern sympto- Von implantierbaren Devices wie Eine besondere Rolle kommt dem ILR matisch, was zur Folge haben kann, dass 2-Kammer-Herzschrittmachern oder bei seltenen, anhaltenden wiederkehren- therapeutische Maßnahmen verzögert Defibrillatoren ist bekannt, dass sie den Palpitationen zu. Im Vergleich zum eingeleitet werden. Dieser Anteil beträgt Vorhofflimmerepisoden mit einer De- konventionellen Rhythmusmonitoring je nach Studienlage bis zu 40 % [26]. tektionsrate von bis zu 98 % zuverlässig konnte die Diagnose nach
Herzschrittmachertherapie + Elektrophysiologie – Springer Journals
Published: Nov 10, 2016
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.