Access the full text.
Sign up today, get DeepDyve free for 14 days.
K. Langford, L. Luchtman-Jones, R. Miller, D. Walck (2003)
Performance evaluation of the Sysmex XT-2000i automated hematology analyzer.Laboratory hematology : official publication of the International Society for Laboratory Hematology, 9 1
T. Ghys, R. Malfait, J. Bossche (2009)
Performance evaluation of the Sysmex XS‐1000i automated haematology analyserInternational Journal of Laboratory Hematology, 31
D. Novis, M. Walsh, D. Wilkinson, M. Louis, J. Ben-Ezra (2009)
Laboratory productivity and the rate of manual peripheral blood smear review: a College of American Pathologists Q-Probes study of 95,141 complete blood count determinations performed in 263 institutions.Archives of pathology & laboratory medicine, 130 5
L. Meintker, J. Ringwald, M. Rauh, S. Krause (2013)
Comparison of automated differential blood cell counts from Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in normal and pathologic samples.American journal of clinical pathology, 139 5
P. Barnes, S. Mcfadden, S. Machin, E. Simson (2005)
The international consensus group for hematology review: suggested criteria for action following automated CBC and WBC differential analysis.Laboratory hematology : official publication of the International Society for Laboratory Hematology, 11 2
G. Gulati, Jinming Song, A. Florea, J. Gong (2012)
Purpose and Criteria for Blood Smear Scan, Blood Smear Examination, and Blood Smear ReviewAnnals of Laboratory Medicine, 33
Ahhyun Kim, Wonbae Lee, Myungshin Kim, Yonggoo Kim, Kyungja Han (2014)
White blood cell differential counts in severely leukopenic samples: a comparative analysis of different solutions available in modern laboratory hematologyBlood research, 49
SO Ike, T Nubila, EO Ukaejiofo, IN Nubila, EN Shu, I Ezema (2010)
Comparison of haematological parameters determined by the Sysmex KX-2IN automated haematology analyzer and the manual countsBMC Clin Pathol, 10
B. Hyun, G. Gulati, J. Ashton (1991)
Differential leukocyte count: manual or automated, what should it be?Yonsei medical journal, 32 4
K. Ruzicka, M. Veitl, R. Thalhammer-scherrer, I. Schwarzinger (2001)
The new hematology analyzer Sysmex XE-2100: performance evaluation of a novel white blood cell differential technology.Archives of pathology & laboratory medicine, 125 3
S. Ike, T. Nubila, E. Ukaejiofo, I. Nubila, E. Shu, I. Ezema
Open Access Research Article Comparison of Haematological Parameters Determined by the Sysmex Kx -2in Automated Haematology Analyzer and the Manual Counts
Sally Kinsey, J. Watts, Middlesex Hospital, London (1988)
Accurate automated leucocyte differential counts despite profound leucopenia.Journal of Clinical Pathology, 41
B. Pratumvinit, P. Wongkrajang, K. Reesukumal, C. Klinbua, Patama Niamjoy (2013)
Validation and optimization of criteria for manual smear review following automated blood cell analysis in a large university hospital.Archives of pathology & laboratory medicine, 137 3
The aim of this study is to evaluate the performance of Sysmex XS-800i analyzer and compare its correlation with standard manual method in oncologic patients. The complete blood count (CBC) with differential leukocyte count is one of the most frequently requested hematologic tests. In oncologic patients, it is more important because primary diagnosis and treatment follow-up are depending on CBC results. Automated hematology analyzers are designed to perform CBC with acceptable precision and accuracy, but manual slide examination still is needed to complement the analyzer results. One thousand CBC samples of oncologic patients analyzed by Sysmex XS-800i analyzer and the corresponding slides were examined independently by a skilled hematology technician and a pathologist. Their results analyzed for finding the degree of correlation between them. Our instrument showed excellent performance with a correlation coefficient of >0.91 for platelet and leukocyte differential count (except for basophil with r = 0.592). Sensitivity and specificity of identifying abnormal cells was 82.7 and 92 %, respectively. The Sysmex XS-800i hematology analyzer results are as reliable as the standard manual method; however, manual microscopic blood examination should be used to complete the uncompleted results, to validate analyzer flags, and for counting the cells with a flag.
Comparative Clinical Pathology – Springer Journals
Published: Aug 13, 2016
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.