Access the full text.
Sign up today, get DeepDyve free for 14 days.
J. Damilakis, G. Papadokostakis, H. Vrahoriti, I. Tsagaraki, A. Hadjipavlou, N. Gourtsoyiannis (2003)
Ultrasound Velocity Through the Cortex of Phalanges, Radius, and Tibia in Normal and Osteoporotic Postmenopausal Women Using a New Multisite Quantitative Ultrasound DeviceInvestigative Radiology, 38
J. Damilakis, K. Perisinakis, E. Vagios, D. Tsinikas, N. Gourtsoyiannis (1998)
Effect of Region of Interest Location on Ultrasound Measurements of the CalcaneusCalcified Tissue International, 63
K. Faulkner, E. Stetten, P. Miller (1999)
Discordance in patient classification using T-scores.Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry, 2 3
H. Jørgensen, L. Warming, N. Bjarnason, P. Andersen, C. Hassager (2001)
How does quantitative ultrasound compare to dual X-ray absorptiometry at various skeletal sites in relation to the WHO diagnosis categories?Clinical physiology, 21 1
C. Njeh, I. Saeed, M. Grigorian, D. Kendler, B. Fan, J. Shepherd, M. McClung, W. Drake, H. Genant (2001)
Assessment of bone status using speed of sound at multiple anatomical sites.Ultrasound in medicine & biology, 27 10
D. Black, S. Cummings, H. Genant, M. Nevitt, L. Palermo, W. Browner (1992)
Axial and appendicular bone density predict fractures in older womenJournal of Bone and Mineral Research, 7
D. Hans, S. Srivastav, C. Singal, R. Barkmann, C. Njeh, E. Kantorovich, C. Glüer, H. Genant (1999)
Does Combining the Results from Multiple Bone Sites Measured by a New Quantitative Ultrasound Device Improve Discrimination of Hip Fracture?Journal of Bone and Mineral Research, 14
Y. Ikeda, M. Iki, A. Morita, H. Aihara, S. Kagamimori, Y. Kagawa, T. Matsuzaki, H. Yoneshima, F. Marumo (2002)
Age-Specific Values and Cutoff Levels for the Diagnosis of Osteoporosis in Quantitative Ultrasound Measurements at the Calcaneus with SAHARA in Healthy Japanese Women: Japanese Population-Based Osteoporosis (JPOS) StudyCalcified Tissue International, 71
J. Kanis, C. Glüer, International Advisors (2000)
An Update on the Diagnosis and Assessment of Osteoporosis with DensitometryOsteoporosis International, 11
J. Fordham, D. Chinn, N. Kumar (2000)
Identification of Women with Reduced Bone Density at the Lumbar Spine and Femoral Neck using BMD at the Os CalcisOsteoporosis International, 11
(1998)
Discrimination between hip fractures and age matched controls using a commercialized multisite quantitative ultrasound device. Bone 23:S638
S. Grampp, C. Henk, Ying Lu, C. Krestan, H. Resch, F. Kainberger, S. Youssefzadeh, F. Vorbeck, H. Imhof (2001)
Quantitative US of the calcaneus: cutoff levels for the distinction of healthy and osteoporotic individuals.Radiology, 220 2
Peter Augat, T. Fuerst, H. Genant (1998)
Quantitative Bone Mineral Assessment at the Forearm: A ReviewOsteoporosis International, 8
H. Genant, K. Engelke, T. Fuerst, C. Glüer, S. Grampp, S. Harris, M. Jergas, T. Lang, Ying Lu, S. Majumdar, A. Mathur, M. Takada (1996)
Noninvasive assessment of bone mineral and structure: State of the artJournal of Bone and Mineral Research, 11
P. Steiger, S. Cummings, D. Black, Nan Spencer, H. Genant (1992)
Age‐related decrements in bone mineral density in women over 65Journal of Bone and Mineral Research, 7
G. Blake, H. Wahner, I. Fogelman (1999)
The evaluation of osteoporosis : dual energy x-ray absorptiometry and ultrasound in clinical practice
J. Truscott (2000)
Quantitative ultrasound—assessment of osteoporosis and bone statusUltrasound in Medicine and Biology, 26
J. Pouillès, F. Trémollieres, S. Martinez, M. Delsol, C. Ribot (2001)
Ability of Peripheral DXA Measurements of the Forearm to Predict Low Axial Bone Mineral Density at MenopauseOsteoporosis International, 12
C. Glüer, S. Cummings, D. Bauer, K. Stone, A. Pressman, A. Mathur, H. Genant (1996)
Osteoporosis: association of recent fractures with quantitative US findings.Radiology, 199 3
D. Bauer, C. Glüer, J. Cauley, T. Vogt, K. Ensrud, H. Genant, D. Black (1997)
Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women. A prospective study. Study of Osteoporotic Fractures Research Group.Archives of internal medicine, 157 6
D. Hans, P. Dargent-Molina, A. Schott, J. Sebert, C. Cormier, P. Kotzki, P. Delmas, J. Pouillès, G. Bréart, P. Meunier (1996)
Ultrasonographic heel measurements to predict hip fracture in elderly women: the EPIDOS prospective studyThe Lancet, 348
Karen Knapp, Glen Blake, T Spector, I. Fogelman (2001)
Multisite Quantitative Ultrasound: Precision, Age- and Menopause-Related Changes, Fracture Discrimination, and T-score Equivalence with Dual-Energy X-ray AbsorptiometryOsteoporosis International, 12
J. Damilakis, K. Perisinakis, N. Gourtsoyiannis (2001)
Imaging Ultrasonometry of the Calcaneus: Optimum T-Score Thresholds for the Identification of Osteoporotic SubjectsCalcified Tissue International, 68
M. Weiss, A. Ben-Shlomo, P. Hagag, S. Ish-Shalom (2000)
Discrimination of Proximal Hip Fracture by Quantitative Ultrasound Measurement at the RadiusOsteoporosis International, 11
J. Damilakis, K. Perisinakis, G. Kontakis, E. Vagios, N. Gourtsoyiannis (1999)
Effect of Lifetime Occupational Physical Activity on Indices of Bone Mineral Status in Healthy Postmenopausal WomenCalcified Tissue International, 64
S. Grampp, P. Lang, M. Jergas, C. Glüer, A. Mathur, K. Engelke, H. Genant (1995)
Assessment of the skeletal status by peripheral quantitative computed tomography of the forearm: Short‐term precision in vivo and comparison to dual X‐ray absorptiometryJournal of Bone and Mineral Research, 10
T. Jones, M. Davie (1998)
Bone mineral density at distal forearm can identify patients with osteoporosis at spine or femoral neck.British journal of rheumatology, 37 5
K. Knapp, G. Blake, I. Fogelman, D. Doyle, T. Spector (2002)
Multisite Quantitative Ultrasound: Colles’ Fracture Discrimination in Postmenopausal WomenOsteoporosis International, 13
G. Blake, R. Patel, I. Fogelman (1998)
Peripheral or axial bone density measurements?Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry, 1 1
(1998)
Discrimination between hip fractures and age matched controls using a commercialized multisite quantitative ultrasound device
The purpose of this study was to investigate the clinical usefulness of forearm bone mineral density (BMD) and speed of sound (SOS) at the phalanx and radius as pre-selection tests to identify women with low BMD at the axial skeleton. BMD was measured by dual-energy X-ray absorptiometry (DXA) in the forearm, lumbar spine and femoral neck. SOS at the radius and phalanx was measured using a multisite quantitative ultrasound (QUS) device. Measurements were performed on 524 consecutive women referred for the assessment of BMD. Women with a T-score <−1 and T-score ≤−2.5 at either spine or femoral neck were identified, and T-score cut-off values for the forearm DXA and QUS variables were determined. Cut-off values for the forearm BMD estimated to detect normal women and those with T-score <−1 at the axial skeleton identified a total of 82% of subjects with 91% certainty. Cut-off values for the forearm BMD determined to detect women with T-score >−2.5 and those with osteoporosis allowed the identification of 62% of the study population with 90% certainty. Cut-off values for the phalangeal and radial SOS estimated to detect normal women and those with T-score <−1 at the axial skeleton identified a total of 49% and 1% of subjects, respectively. Cut-off values estimated for QUS variables to detect women with T-score >−2.5 and those with osteoporosis at the axial skeleton either failed to detect subjects with sufficient certainty (phalangeal SOS) or detected a negligible percentage of patients (radial SOS). In conclusion, forearm BMD may be used as a pre-selection test to identify women with low BMD at the axial skeleton, thus enabling reduction of the number of women who need axial BMD assessment. SOS of the phalanges and radius appears to have less value in the detection of the women with low axial BMD.
Osteoporosis International – Springer Journals
Published: Jul 24, 2003
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.