A dual purpose Compton suppression spectrometer

A dual purpose Compton suppression spectrometer A gamma-ray spectrometer with a passive and an active shield is described. It consists of a HPGe coaxial detector of 42% efficiency and 4 NaI(Tl) detectors. The energy output pulses of the Ge detector are delivered into the 3 spectrometry chains giving the normal, anti- and coincidence spectra. From the spectra of a number of 137 Cs and 60 Co sources a Compton suppression factor, SF and a Compton reduction factor, RF, as the parameters characterizing the system performance, were calculated as a function of energy and source activity and compared with those given in literature. The natural background is reduced about 8 times in the anticoincidence mode of operation, compared to the normal spectrum which results in decreasing the detection limits for non-coincident gamma-rays up to a factor of 3. In the presence of other gamma-ray activities, in the range from 5 to 11 kBq, non- and coincident, the detection limits can be decreased for some nuclides by a factor of 3 to 5.7. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Radioanalytical and Nuclear Chemistry Springer Journals

A dual purpose Compton suppression spectrometer

Loading next page...
 
/lp/springer-journals/a-dual-purpose-compton-suppression-spectrometer-vV0qHLloBW

References (26)

Publisher
Springer Journals
Copyright
Copyright © 2003 by Kluwer Academic Publishers/Akadémiai Kiadó
Subject
Chemistry; Inorganic Chemistry; Physical Chemistry; Diagnostic Radiology; Nuclear Physics, Heavy Ions, Hadrons
ISSN
0236-5731
eISSN
1588-2780
DOI
10.1023/A:1026270428392
Publisher site
See Article on Publisher Site

Abstract

A gamma-ray spectrometer with a passive and an active shield is described. It consists of a HPGe coaxial detector of 42% efficiency and 4 NaI(Tl) detectors. The energy output pulses of the Ge detector are delivered into the 3 spectrometry chains giving the normal, anti- and coincidence spectra. From the spectra of a number of 137 Cs and 60 Co sources a Compton suppression factor, SF and a Compton reduction factor, RF, as the parameters characterizing the system performance, were calculated as a function of energy and source activity and compared with those given in literature. The natural background is reduced about 8 times in the anticoincidence mode of operation, compared to the normal spectrum which results in decreasing the detection limits for non-coincident gamma-rays up to a factor of 3. In the presence of other gamma-ray activities, in the range from 5 to 11 kBq, non- and coincident, the detection limits can be decreased for some nuclides by a factor of 3 to 5.7.

Journal

Journal of Radioanalytical and Nuclear ChemistrySpringer Journals

Published: Sep 1, 2003

There are no references for this article.