Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Perventricular device closure of perimembranous ventricular septal defect: effectiveness of symmetric and asymmetric occluders

Perventricular device closure of perimembranous ventricular septal defect: effectiveness of... AbstractOBJECTIVES: To assess safety and effectiveness of symmetric and asymmetric occluders in perventricular device closure without cardiopulmonary bypass of perimembranous ventricular septal defects (pmVSDs).METHODS: The present retrospective study enrolled 581 patients who underwent perventricular device closure of pmVSDs under transoesophageal echocardiography guidance from May 2011 to April 2016, and outpatient electrocardiography and transthoracic echocardiography assessments at 1, 3, 6 and 12 months, and yearly thereafter.RESULTS: The overall success rate of device implantation was 92.6% (43 surgical conversions immediately). Between patients receiving symmetric (n = 353) and asymmetric (n = 185) occluders, there were no significant differences in age, weight and defect diameter distributions; however, both before discharge and at mean 28.6 ± 21.2 (range, 1–60)-month follow-up, the symmetric group had lower rates of trivial residual shunt (5.7% vs 11.4%, P = 0.018; and 0.8% vs 5.9%, P = 0.001) and bundle branch block (0.8% vs 5.4%, P = 0.002; and 0.6% vs 3.8%, P = 0.009); and at follow-up, the asymmetric group had lower residual shunt (47.6% vs 85.0%, P = 0.020) and similar branch block (30.0% vs 33.3%, P = 1.000) disappearance rates. There were no severe complications, i.e. aortic regurgitation, malignant arrhythmias, haemolysis or device dislocation.CONCLUSIONS: Perventricular device closure of pmVSDs appears safe and effective with symmetric and asymmetric occluders. However, the lower residual shunt disappearance and higher branch block incidence rates for asymmetric occluders would favour more proactive conversion to surgical repair immediately when residual shunt is present intraoperatively. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png European Journal of Cardio-Thoracic Surgery Oxford University Press

Perventricular device closure of perimembranous ventricular septal defect: effectiveness of symmetric and asymmetric occluders

Loading next page...
 
/lp/oxford-university-press/perventricular-device-closure-of-perimembranous-ventricular-septal-TmkF0E6IUM

References (20)

Publisher
Oxford University Press
Copyright
© The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
ISSN
1010-7940
eISSN
1873-734X
DOI
10.1093/ejcts/ezw352
pmid
28082474
Publisher site
See Article on Publisher Site

Abstract

AbstractOBJECTIVES: To assess safety and effectiveness of symmetric and asymmetric occluders in perventricular device closure without cardiopulmonary bypass of perimembranous ventricular septal defects (pmVSDs).METHODS: The present retrospective study enrolled 581 patients who underwent perventricular device closure of pmVSDs under transoesophageal echocardiography guidance from May 2011 to April 2016, and outpatient electrocardiography and transthoracic echocardiography assessments at 1, 3, 6 and 12 months, and yearly thereafter.RESULTS: The overall success rate of device implantation was 92.6% (43 surgical conversions immediately). Between patients receiving symmetric (n = 353) and asymmetric (n = 185) occluders, there were no significant differences in age, weight and defect diameter distributions; however, both before discharge and at mean 28.6 ± 21.2 (range, 1–60)-month follow-up, the symmetric group had lower rates of trivial residual shunt (5.7% vs 11.4%, P = 0.018; and 0.8% vs 5.9%, P = 0.001) and bundle branch block (0.8% vs 5.4%, P = 0.002; and 0.6% vs 3.8%, P = 0.009); and at follow-up, the asymmetric group had lower residual shunt (47.6% vs 85.0%, P = 0.020) and similar branch block (30.0% vs 33.3%, P = 1.000) disappearance rates. There were no severe complications, i.e. aortic regurgitation, malignant arrhythmias, haemolysis or device dislocation.CONCLUSIONS: Perventricular device closure of pmVSDs appears safe and effective with symmetric and asymmetric occluders. However, the lower residual shunt disappearance and higher branch block incidence rates for asymmetric occluders would favour more proactive conversion to surgical repair immediately when residual shunt is present intraoperatively.

Journal

European Journal of Cardio-Thoracic SurgeryOxford University Press

Published: Mar 1, 2017

There are no references for this article.