Depth Electrode Implantation in the Length Axis of the Hippocampus for the Presurgical Evaluation of Medial Temporal Lobe Epilepsy: A Computed Tomography-based Stereotactic Insertion Technique and Its Accuracy

Depth Electrode Implantation in the Length Axis of the Hippocampus for the Presurgical Evaluation... AbstractOBJECTIVE:An individualized computed tomography-based stereotactic technique for the longitudinal insertion of intrahippocampal electrodes is presented and its accuracy described.METHODS:The technique makes use of one well reproducible target in the hippocampal head and of the approximate inclination of the anteroposterior length axis of the hippocampus, for which the orbital floor is taken as an auxiliary landmark. It was used in 141 patients with medically intractable complex partial seizures. In 106 patients, magnetic resonance imaging (MRI) was available for assessment of implantation accuracy. Each of the 212 electrodes was plotted on topographic drawings and its goodness of fit rated.RESULTS:Whereas hippocampal head and body were hit by 97 and 96% of the electrodes, respectively, the amygdala was hit by only 75% of the electrodes and mainly at its basal margin. For 93% of the electrodes, the inclination in a sagittal plane corresponded exactly to that of the hippocampus. The implantation morbidity amounted to 5.7%, whereas permanent neurological deficit occurred in one (0.7%) of the 141 patients.CONCLUSION:This computed tomography-based protocol proved to be reliable and hence can be considered as an adequate alternative to MRI-based stereotactic implantation if MRI is not available or if a single MRI-based stereotactic set-up is unreliable because of intolerable distortions. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Neurosurgery Oxford University Press

Depth Electrode Implantation in the Length Axis of the Hippocampus for the Presurgical Evaluation of Medial Temporal Lobe Epilepsy: A Computed Tomography-based Stereotactic Insertion Technique and Its Accuracy

Depth Electrode Implantation in the Length Axis of the Hippocampus for the Presurgical Evaluation of Medial Temporal Lobe Epilepsy: A Computed Tomography-based Stereotactic Insertion Technique and Its Accuracy

T E C H N IQ U E ASSESSM ENTS Depth Electrode Implantation in the Length Axis of the Hippocampus for the Presurgical Evaluation of Medial Temporal Lobe Epilepsy: A Computed Tomography-based Stereotactic Insertion Technique and Its Accuracy Dirk Van Roost, M.D., Laszlo Solymosi, M.D., Johannes Schramm, M.D., Birgitt van Oosterwyck, D.M.D., Christian E. Eiger, M.D. Departments of Neurosurgery (D VR, JS, BvO), Neuroradiology (LS), and Epileptology (CEE), University of Bonn, Bonn, Germany OBJECTIVE: An individualized computed tomography-based stereotactic technique for the longitudinal insertion of intrahippocampal electrodes is presented and its accuracy described. METHODS: The technique makes use of one well reproducible target in the hippocampal head and of the approximate inclination of the anteroposterior length axis of the hippocampus, for which the orbital floor is taken as an auxiliary landmark. It was used in 141 patients with medically intractable complex partial seizures. In 106 patients, magnetic resonance imaging (MRI) was available for assessment of implantation accuracy. Each of the 2 1 2 electrodes was plotted on topographic drawings and its goodness of fit rated. RESULTS: Whereas hippocampal head and body were hit by 97 and 96% of the electrodes, respectively, the amygdala was hit by only 75% of the electrodes and mainly at its basal margin. For 9 3 % of the electrodes, the inclination in a sagittal plane corresponded exactly to that of the hippocampus. The implantation morbidity amounted to 5 .7 % , whereas permanent neurological deficit occurred in one (0.7% ) of the 141 patients. CONCLUSION: This computed tomography-based protocol proved to be reliable and hence can be considered as an adequate alternative to MRI-based stereotactic implantation if MRI is not available or if a single MRI-based stereotactic set-up is unreliable because of intolerable distortions. (N e u ro su rg e ry 4 3 : 8 1 9 - 8 2 7 , 1998) Keywords: Computed tomography, Depth...
Loading next page...
 
/lp/ou_press/depth-electrode-implantation-in-the-length-axis-of-the-hippocampus-for-gPmdwRlT6G
Publisher
Oxford University Press
Copyright
© Published by Oxford University Press.
ISSN
0148-396X
eISSN
1524-4040
D.O.I.
10.1097/00006123-199810000-00058
Publisher site
See Article on Publisher Site

Abstract

AbstractOBJECTIVE:An individualized computed tomography-based stereotactic technique for the longitudinal insertion of intrahippocampal electrodes is presented and its accuracy described.METHODS:The technique makes use of one well reproducible target in the hippocampal head and of the approximate inclination of the anteroposterior length axis of the hippocampus, for which the orbital floor is taken as an auxiliary landmark. It was used in 141 patients with medically intractable complex partial seizures. In 106 patients, magnetic resonance imaging (MRI) was available for assessment of implantation accuracy. Each of the 212 electrodes was plotted on topographic drawings and its goodness of fit rated.RESULTS:Whereas hippocampal head and body were hit by 97 and 96% of the electrodes, respectively, the amygdala was hit by only 75% of the electrodes and mainly at its basal margin. For 93% of the electrodes, the inclination in a sagittal plane corresponded exactly to that of the hippocampus. The implantation morbidity amounted to 5.7%, whereas permanent neurological deficit occurred in one (0.7%) of the 141 patients.CONCLUSION:This computed tomography-based protocol proved to be reliable and hence can be considered as an adequate alternative to MRI-based stereotactic implantation if MRI is not available or if a single MRI-based stereotactic set-up is unreliable because of intolerable distortions.

Journal

NeurosurgeryOxford University Press

Published: Oct 1, 1998

There are no references for this article.

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 18 million articles from more than
15,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Search

Query the DeepDyve database, plus search all of PubMed and Google Scholar seamlessly

Organize

Save any article or search result from DeepDyve, PubMed, and Google Scholar... all in one place.

Access

Get unlimited, online access to over 18 million full-text articles from more than 15,000 scientific journals.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve

Freelancer

DeepDyve

Pro

Price

FREE

$49/month
$360/year

Save searches from
Google Scholar,
PubMed

Create lists to
organize your research

Export lists, citations

Read DeepDyve articles

Abstract access only

Unlimited access to over
18 million full-text articles

Print

20 pages / month

PDF Discount

20% off