Structural Fire Performance of Innovative Moment-Resisting Connection Joining Steel Beams to HSS Columns

Structural Fire Performance of Innovative Moment-Resisting Connection Joining Steel Beams to HSS... In this paper, experimental results of the structural fire behaviour of four large-scale steel frame test assemblies are presented. Test assemblies were made of HSS beams and columns connected together using an innovative extended end-plate moment connection configuration. Two different parameters were investigated, the connection end plate thickness and the degree of beam axial restraint. The fire performance of this beam-to-column configuration was compared to the behaviour of a commonly-used connection configuration with similar parameters and fire testing conditions. The newly-developed connection configuration behaved in a more flexible manner at elevated temperature than the regular configuration. In addition to improved constructability and pleasant appearance, the new connection configuration exhibits greater moment-carrying capacity and enhanced fire resistance characteristics. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Structural Fire Engineering Emerald Publishing

Structural Fire Performance of Innovative Moment-Resisting Connection Joining Steel Beams to HSS Columns

Loading next page...
 
/lp/emerald-publishing/structural-fire-performance-of-innovative-moment-resisting-connection-PjQ0q8KdU8
Publisher
Emerald Publishing
Copyright
Copyright © Emerald Group Publishing Limited
ISSN
2040-2317
DOI
10.1260/2040-2317.5.4.331
Publisher site
See Article on Publisher Site

Abstract

In this paper, experimental results of the structural fire behaviour of four large-scale steel frame test assemblies are presented. Test assemblies were made of HSS beams and columns connected together using an innovative extended end-plate moment connection configuration. Two different parameters were investigated, the connection end plate thickness and the degree of beam axial restraint. The fire performance of this beam-to-column configuration was compared to the behaviour of a commonly-used connection configuration with similar parameters and fire testing conditions. The newly-developed connection configuration behaved in a more flexible manner at elevated temperature than the regular configuration. In addition to improved constructability and pleasant appearance, the new connection configuration exhibits greater moment-carrying capacity and enhanced fire resistance characteristics.