Influence of the thickness of intumescent paint in the position of steels (fire safety)

Influence of the thickness of intumescent paint in the position of steels (fire safety) PurposeThe purpose of this paper is to analyze a new structural design applied in industrial frames using two type of steels (S275 and fire resistant (FR)) with different mechanical resistance against fire. To do it, the authors have taken into account variables such as intrinsic metallic design, span length, intumescent paint thickness, and fire time exposure, which offers information about new scenarios of design in industry.Design/methodology/approachThe key methodology followed has taken into account a modeling program that uses the following variables: 25 and 35 m of span, 45 and 60 fire exposure times, and seven different intumescent paint thickness. An optimum structural design has been evaluated by discretization of each scenario with the particular type of steel, S275 and FR. The obtained approach could be a good guideline for future designs.FindingsThe results and analysis have shown a very good and valid idea of a new structural typology using optimum intumescent paint thickness into the final design of the industrial frame considering that it has two different types of steel. It is in realty a handicap since usually mechanical engineers employ structural steel without paying attention to this new feature.Practical implicationsCheaper structural designs could be obtained using the two different types of steel considering the proper positioning into the full building.Originality/valueThe validity of design of two types of steel plus intumescent paint in building construction has been shown, and this study will encourage designers to use it, in particular in buildings with high fire risk. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png International Journal of Structural Integrity Emerald Publishing

Influence of the thickness of intumescent paint in the position of steels (fire safety)

Loading next page...
 
/lp/emerald-publishing/influence-of-the-thickness-of-intumescent-paint-in-the-position-of-isXDdz4ZOy
Publisher
Emerald Publishing
Copyright
Copyright © Emerald Group Publishing Limited
ISSN
1757-9864
DOI
10.1108/IJSI-07-2016-0024
Publisher site
See Article on Publisher Site

Abstract

PurposeThe purpose of this paper is to analyze a new structural design applied in industrial frames using two type of steels (S275 and fire resistant (FR)) with different mechanical resistance against fire. To do it, the authors have taken into account variables such as intrinsic metallic design, span length, intumescent paint thickness, and fire time exposure, which offers information about new scenarios of design in industry.Design/methodology/approachThe key methodology followed has taken into account a modeling program that uses the following variables: 25 and 35 m of span, 45 and 60 fire exposure times, and seven different intumescent paint thickness. An optimum structural design has been evaluated by discretization of each scenario with the particular type of steel, S275 and FR. The obtained approach could be a good guideline for future designs.FindingsThe results and analysis have shown a very good and valid idea of a new structural typology using optimum intumescent paint thickness into the final design of the industrial frame considering that it has two different types of steel. It is in realty a handicap since usually mechanical engineers employ structural steel without paying attention to this new feature.Practical implicationsCheaper structural designs could be obtained using the two different types of steel considering the proper positioning into the full building.Originality/valueThe validity of design of two types of steel plus intumescent paint in building construction has been shown, and this study will encourage designers to use it, in particular in buildings with high fire risk.

Journal

International Journal of Structural IntegrityEmerald Publishing

Published: Jun 12, 2017

References