Enhanced phase-domain synchronous machine model including saturation

Enhanced phase-domain synchronous machine model including saturation PurposeThe phase-domain synchronous machine model has advantages compared to the d/q model, as no transformation of currents is necessary at each time step in a network analysis. The purpose of this paper is to enhance the phase-domain model to calculate the current distribution of the damper bars, including the saturation.Design/methodology/approachThe new enhanced phase-domain model of the synchronous machine has been modelled using Matlab-Simulink. The parameters of the model have been calculated by using FEA software.FindingsIt is shown that the simulation results of the new model show very good accordance to the reference model during a three-phase short circuit.Originality/valueThe enhanced model includes the calculation of the currents in the damper bar and is able to include the harmonics of the inductances. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png COMPEL: Theinternational Journal for Computation and Mathematics in Electrical and Electronic Engineering Emerald Publishing

Loading next page...
 
/lp/emerald-publishing/enhanced-phase-domain-synchronous-machine-model-including-saturation-ZAERZN00px
Publisher
Emerald Publishing
Copyright
Copyright © Emerald Group Publishing Limited
ISSN
0332-1649
DOI
10.1108/COMPEL-09-2016-0410
Publisher site
See Article on Publisher Site

Abstract

PurposeThe phase-domain synchronous machine model has advantages compared to the d/q model, as no transformation of currents is necessary at each time step in a network analysis. The purpose of this paper is to enhance the phase-domain model to calculate the current distribution of the damper bars, including the saturation.Design/methodology/approachThe new enhanced phase-domain model of the synchronous machine has been modelled using Matlab-Simulink. The parameters of the model have been calculated by using FEA software.FindingsIt is shown that the simulation results of the new model show very good accordance to the reference model during a three-phase short circuit.Originality/valueThe enhanced model includes the calculation of the currents in the damper bar and is able to include the harmonics of the inductances.

Journal

COMPEL: Theinternational Journal for Computation and Mathematics in Electrical and Electronic EngineeringEmerald Publishing

Published: May 2, 2017