Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You and Your Team.

Learn More →

Effect of temperature on stress–strain behaviour of pre-damaged confined concrete

Effect of temperature on stress–strain behaviour of pre-damaged confined concrete PurposeThis paper aims to study the residual test results under uni-axial compression of tie confined pre-damaged normal strength concrete short columns subjected to elevated temperatures.Design/methodology/approachThe test variables included temperature of exposure, spacing of transverse confining reinforcement and pre-damage level. An experimental program was designed and carried out involving testing of hoop confined concrete cylindrical specimens exposed to elevated temperatures ranging from room temperature to 900 °C.FindingsThe test results indicate that the residual strength, strain corresponding to the peak stress and the post-peak strains of confined concrete are not affected significantly up to an exposure temperature of 300 °C. However, the peak confined stress falls and the corresponding strain increase considerably in the temperature range of 600 to 900 °C. It is shown that an increase in the degree of confinement reinforcement results in an increased residual strength and deformability of pre-damaged confined concrete.Research limitations/implicationsIt is applicable in finding the residual strength and strain of the pre-damaged confined concrete in uni-axial compression after exposure to elevated temperature.Practical implicationsThe practical implications is that the test result is applicable in finding the residual strengths of pre-damaged confined concrete under uni-axial compression after exposure to elevated temperature.Social implicationsThe main aim of the present investigation is to provide experimental data on the residual behaviour of pre-damaged confined concrete subjected to high temperatures.Originality/valueThe results of this study may be useful for developing the guidelines for designing the confinement reinforcement of reinforced concrete columns against the combined actions of earthquake and fire, as well as for designing the retrofitting schemes after these sequential disasters. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Structural Fire Engineering Emerald Publishing

Effect of temperature on stress–strain behaviour of pre-damaged confined concrete

Journal of Structural Fire Engineering , Volume 11 (1): 33 – Jan 1, 1

Loading next page...
 
/lp/emerald-publishing/effect-of-temperature-on-stress-strain-behaviour-of-pre-damaged-Q0gLUX4wG1
Publisher
Emerald Publishing
Copyright
Copyright © Emerald Group Publishing Limited
ISSN
2040-2317
DOI
10.1108/jsfe-03-2019-0019
Publisher site
See Article on Publisher Site

Abstract

PurposeThis paper aims to study the residual test results under uni-axial compression of tie confined pre-damaged normal strength concrete short columns subjected to elevated temperatures.Design/methodology/approachThe test variables included temperature of exposure, spacing of transverse confining reinforcement and pre-damage level. An experimental program was designed and carried out involving testing of hoop confined concrete cylindrical specimens exposed to elevated temperatures ranging from room temperature to 900 °C.FindingsThe test results indicate that the residual strength, strain corresponding to the peak stress and the post-peak strains of confined concrete are not affected significantly up to an exposure temperature of 300 °C. However, the peak confined stress falls and the corresponding strain increase considerably in the temperature range of 600 to 900 °C. It is shown that an increase in the degree of confinement reinforcement results in an increased residual strength and deformability of pre-damaged confined concrete.Research limitations/implicationsIt is applicable in finding the residual strength and strain of the pre-damaged confined concrete in uni-axial compression after exposure to elevated temperature.Practical implicationsThe practical implications is that the test result is applicable in finding the residual strengths of pre-damaged confined concrete under uni-axial compression after exposure to elevated temperature.Social implicationsThe main aim of the present investigation is to provide experimental data on the residual behaviour of pre-damaged confined concrete subjected to high temperatures.Originality/valueThe results of this study may be useful for developing the guidelines for designing the confinement reinforcement of reinforced concrete columns against the combined actions of earthquake and fire, as well as for designing the retrofitting schemes after these sequential disasters.

Journal

Journal of Structural Fire EngineeringEmerald Publishing

Published: Jan 1, 1

There are no references for this article.

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 18 million articles from more than
15,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Search

Query the DeepDyve database, plus search all of PubMed and Google Scholar seamlessly

Organize

Save any article or search result from DeepDyve, PubMed, and Google Scholar... all in one place.

Access

Get unlimited, online access to over 18 million full-text articles from more than 15,000 scientific journals.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve

Freelancer

DeepDyve

Pro

Price

FREE

$49/month
$499/year

Save searches from
Google Scholar,
PubMed

Create folders to
organize your research

Export folders, citations

Read DeepDyve articles

Abstract access only

Unlimited access to over
18 million full-text articles

Print

20 pages / month