Access the full text.
Sign up today, get DeepDyve free for 14 days.
Burak Öztürk, L. Uğur, F. Erzincanli, Ö. Küçük (2018)
Optimization of Polyethylene Inserts Design Geometry of Total Knee Prosthesis, 2
M. Kibar, Orhan Özcan, Yeşim Dusova-Teke, Esra Yonel-Gumruk, A. Akın (2016)
Optimization, modeling and characterization of sol-gel process parameters for the synthesis of nanostructured boron doped alumina catalyst supportsMicroporous and Mesoporous Materials, 229
H. Sanecki, A. Zieliński (2006)
Crack propagation modelled by T‐elementsEngineering Computations, 23
R. Laskin (1978)
Unicompartmental tibiofemoral resurfacing arthroplasty.The Journal of bone and joint surgery. American volume, 60 2
Sander Minnoye, D. Plettenburg (2009)
Design, Fabrication, and Preliminary Results of a Novel Below-Knee Prosthesis for Snowboarding: A Case ReportProsthetics and Orthotics International, 33
Yifei Dai, G. Scuderi**, Charles Penninger, J. Bischoff, A. Rosenberg (2014)
Increased shape and size offerings of femoral components improve fit during total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 22
C. Luring, L. Perlick, T. Schubert, M. Tingart (2007)
A rare cause for knee pain: fracture of the femoral component after TKR. A case reportKnee Surgery, Sports Traumatology, Arthroscopy, 15
M. Wada, S. Imura, A. Bo, H. Baba, T. Miyazaki (1997)
Stress fracture of the femoral component in total knee replacement: a report of 3 casesInternational Orthopaedics, 21
S. Boran, C. Hurson, K. Synnott, P. Keogh (2005)
Biomechanical analysis of tibial tray fractures post total knee arthroplastyEuropean Journal of Orthopaedic Surgery & Traumatology, 15
Chang-Hung Huang, Lin-I Hsu, Ting-Kuo Chang, Tai-Yuan Chuang, S. Shih, Yung-Chang Lu, Chen-Sheng Chen, Chun‐Hsiung Huang (2014)
Stress distribution of the patellofemoral joint in the anatomic V-shape and curved dome-shape femoral component: a comparison of resurfaced and unresurfaced patellaeKnee Surgery, Sports Traumatology, Arthroscopy, 25
Nagarajan Chandran, F. Amirouche, Mark Gonzalez*, Kevin Hilton, R. Barmada, W. Goldstein (2009)
Optimisation of the posterior stabilised tibial post for greater femoral rollback after total knee arthroplasty—a finite element analysisInternational Orthopaedics, 33
M. Bahraminasab, B. Sahari, K. Edwards, F. Farahmand, Ali Jahan, T. Hong, M. Arumugam (2014)
On the influence of shape and material used for the femoral component pegs in knee prostheses for reducing the problem of aseptic looseningMaterials & Design, 55
N. Masmiati, A. Sarhan (2015)
Optimizing Cutting Parameters in Inclined End Milling for Minimum Surface Residual Stress - Taguchi ApproachMeasurement, 60
(2017)
Development of design geometry of aluminum fittings for healthy and safety sanitary installations
L. Ilzarbe, M. Álvarez, E. Viles, M. Tanco (2008)
Practical applications of design of experiments in the field of engineering: a bibliographical reviewQuality and Reliability Engineering International, 24
Todd Borus, T. Thornhill (2008)
Unicompartmental Knee ArthroplastyJournal of the American Academy of Orthopaedic Surgeons, 16
T. Villa, F. Migliavacca, D. Gastaldi, M. Colombo, R. Pietrabissa (2004)
Contact stresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations.Journal of biomechanics, 37 1
H. Cameron, R. Welsh (1990)
Fracture of the femoral component in unicompartmental total knee arthroplasty.The Journal of arthroplasty, 5 4
J. Insall, P. Aglietti (1980)
A five to seven-year follow-up of unicondylar arthroplasty.The Journal of bone and joint surgery. American volume, 62 8
R. Willing, I. Kim (2009)
Three dimensional shape optimization of total knee replacements for reduced wearStructural and Multidisciplinary Optimization, 38
(2017)
Investigation of the design parameters affecting the safety factor in fittings by using Taguchi method
C. Vertullo, S. Graves, Yi Peng, P. Lewis (2018)
An optimum prosthesis combination of low-risk total knee arthroplasty options in all five primary categories of design results in a 60% reduction in revision risk: a registry analysis of 482,373 prosthesesKnee Surgery, Sports Traumatology, Arthroscopy, 27
D. Heever, C. Scheffer, P. Erasmus, E. Dillon (2011)
Method for selection of femoral component in total knee arthroplasty (tka)Australasian Physical & Engineering Sciences in Medicine, 34
B. Rawal, A. Yadav, V. Pare (2016)
Life Estimation of Knee Joint Prosthesis by Combined Effect of Fatigue and WearProcedia Technology, 23
M. Bahraminasab, B. Sahari, K. Edwards, F. Farahmand, T. Hong, M. Arumugam, Ali Jahan (2014)
Multi-objective design optimization of functionally graded material for the femoral component of a total knee replacementMaterials & Design, 53
P. Sandborn, S. Cook, M. Kester, R. Haddad (1987)
Fatigue failure of the femoral component of a unicompartmental knee.Clinical orthopaedics and related research, 222
H. Veen, J. Raay (2014)
Fracture of an Oxford femoral component: A case reportKnee, 21
(2008)
Changes in the flexion relaxation response induced by lumbar muscle fatigue
Satish Tumulu, D. Sarkar (2018)
Computer-aided design, finite element analysis and material-model optimisation of knee prosthesisJournal of the Australian Ceramic Society, 54
(2010)
Minitab User Manual Release 16.2, making data analysis easier
Engin Nas, Burak Öztürk (2018)
Optimization of surface roughness via the Taguchi method and investigation of energy consumption when milling spheroidal graphite cast iron materialsMaterials Testing, 60
BMC Musculoskeletal Disorders, 91
Wu-Lin Chen, Chin-Yin Huang, Chi‐Wei Hung (2010)
Optimization of plastic injection molding process by dual response surface method with non‐linear programmingEngineering Computations, 27
K. Panousis, C. Murnaghan, Petra Koettig, P. Grigoris (2004)
Fracture of the femoral component of a Brigham unicompartmental knee: a case reportKnee Surgery, Sports Traumatology, Arthroscopy, 12
This study aims to design a femoral component with minimum volume and maximum safety coefficient. Total knee prosthesis is a well-established therapy in arthroplasty applications. And in particular, with respect to damaged or weakened cartilage, new prostheses are being manufactured from bio-materials which are compatible with the human body to replace these damages. A new universal method (design method requiring optimum volume and safety [DMROVAS]) was propounded to find the optimum design parameters of tibial component.Design/methodology/approachThe design montage was analyzed via the finite element method (FEM). To ensure the stability of the prosthesis, the maximum stress angle and magnitude of the force on the knee were taken into consideration. In the analysis process, results revealed two different maximum stress areas which were supported by case reports in the literature. Variations of maximum stress, safety factor and weight were revealed by FEM analysis, and ANOVA was used to determine the F force percentage for each of the design parameters.FindingsOptimal design parameter levels were chosen for the individual’s minimum weight. Stress maps were constructed to optimize design choices that enabled further enhancement of the design models. The safety factor variation (SFV) of 5.73 was obtained for the volume of 39,219 mL for a region which had maximum stress. At the same time, for a maximum SFV and at the same time an average weight, values of 37,308 mL and 5.8 for volume and SFV were attained, respectively, using statistical methods.Originality/valueThis proposed optimal design development method is new and one that can be used for many biomechanical products and universal industrial designs.
Engineering Computations: International Journal for Computer-Aided Engineering and Software – Emerald Publishing
Published: Aug 12, 2019
Keywords: Parametric design; Total knee prosthesis; Arthroplasty; Design optimization method; Femoral component
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.