Comparative analysis of dual second-order generalized integrator-phase locked loop based series hybrid filter and static synchronous compensator for load voltage compensation and power quality improvement with grid synchronization in islanded microgrid

Comparative analysis of dual second-order generalized integrator-phase locked loop based series... The purpose of this study is to eliminate voltage harmonics and instantly measure the positive sequence fundamental voltage during unbalanced grid conditions, the dual second-order generalized integrator-phase locked loop used in series hybrid filter structures is often used in grid synchronisation in three-phase networks. The preferred series active hybrid power filter simultaneously compensates for voltage balancing and current harmonics generated by non-linear loads.Design/methodology/approachThis paper examines the use of renewable energy–based microgrid (MG) to support linear and non-linear loads. It is capable of synchronising with both the utility and the diesel generator unit. Power is transferred from the grid throughout a stable grid situation with minimum renewable energy generation and maximum load demand. It synchronises with diesel generator set to supply the load and form an AC MG during outages and minimum renewable power generation. In islanded and grid-connected mode, the voltage and power quality issues of the MG are controlled by static synchronous compensator and series hybrid filter.FindingsBecause of the presence of non-linear loads, reactive loads in the distribution system and the injection of wind power into the grid integrated system result power quality issues like current harmonics, voltage fluctuations, reactive power demand, etc.Originality/valueThe voltage at the load (linear and non-linear) is regulated, and the power factor and total harmonic distortions were improved with the help of the series hybrid filter. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Circuit World Emerald Publishing

Comparative analysis of dual second-order generalized integrator-phase locked loop based series hybrid filter and static synchronous compensator for load voltage compensation and power quality improvement with grid synchronization in islanded microgrid

Loading next page...
 
/lp/emerald-publishing/comparative-analysis-of-dual-second-order-generalized-integrator-phase-Zv3VPebhpL

References (39)

Publisher
Emerald Publishing
Copyright
© Emerald Publishing Limited
ISSN
0305-6120
eISSN
0305-6120
DOI
10.1108/cw-05-2021-0157
Publisher site
See Article on Publisher Site

Abstract

The purpose of this study is to eliminate voltage harmonics and instantly measure the positive sequence fundamental voltage during unbalanced grid conditions, the dual second-order generalized integrator-phase locked loop used in series hybrid filter structures is often used in grid synchronisation in three-phase networks. The preferred series active hybrid power filter simultaneously compensates for voltage balancing and current harmonics generated by non-linear loads.Design/methodology/approachThis paper examines the use of renewable energy–based microgrid (MG) to support linear and non-linear loads. It is capable of synchronising with both the utility and the diesel generator unit. Power is transferred from the grid throughout a stable grid situation with minimum renewable energy generation and maximum load demand. It synchronises with diesel generator set to supply the load and form an AC MG during outages and minimum renewable power generation. In islanded and grid-connected mode, the voltage and power quality issues of the MG are controlled by static synchronous compensator and series hybrid filter.FindingsBecause of the presence of non-linear loads, reactive loads in the distribution system and the injection of wind power into the grid integrated system result power quality issues like current harmonics, voltage fluctuations, reactive power demand, etc.Originality/valueThe voltage at the load (linear and non-linear) is regulated, and the power factor and total harmonic distortions were improved with the help of the series hybrid filter.

Journal

Circuit WorldEmerald Publishing

Published: Feb 6, 2023

Keywords: PMSG-based wind turbine; Power quality (PQ); Series hybrid filters (SHF); Static synchronous compensator (STATCOM); Dual second-order generalized integrator phase locked loop (DSOGI-PLL)