A novel apparatus to measure the biomechanical properties of blood vessels

A novel apparatus to measure the biomechanical properties of blood vessels The study of vascular mechanics is important. The purpose of this paper is to present an apparatus to measure the biomechanical properties of blood vessels, which can be used for tensile test and fatigue test.Design/methodology/approachThis equipment consists of a mechanical test platform, a hardware circuit based on FPGA and control software. The torque generated by stepper motor is converted to axial force by ball screw, and the vascular specimen is stretched axially. The tension is measured by a load cell, and the displacement is recorded by a grating displacement sensor.FindingsAccording to the results of calibration experiment and stability experiment, the linearity error of the system is 0.251, the hysteresis error is 0.047, the repeatability error is 0.185, the comprehensive error is 0.315 and the standard deviation of the output is less than 0.01 N. A test of animal vascular mechanical properties was carried out, and the results are consistent with the theory.Originality/valueThis apparatus is designed to measure biomechanical properties of blood vessels, and the results of experiments indicate that it is stable and reliable. This work is valuable for studying vascular disease and testing artificial blood vessels. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Sensor Review Emerald Publishing

A novel apparatus to measure the biomechanical properties of blood vessels

Sensor Review , Volume 40 (4): 8 – Jul 21, 2020

Loading next page...
 
/lp/emerald-publishing/a-novel-apparatus-to-measure-the-biomechanical-properties-of-blood-30YsCISkM0
Publisher
Emerald Publishing
Copyright
© Emerald Publishing Limited
ISSN
0260-2288
DOI
10.1108/sr-01-2019-0023
Publisher site
See Article on Publisher Site

Abstract

The study of vascular mechanics is important. The purpose of this paper is to present an apparatus to measure the biomechanical properties of blood vessels, which can be used for tensile test and fatigue test.Design/methodology/approachThis equipment consists of a mechanical test platform, a hardware circuit based on FPGA and control software. The torque generated by stepper motor is converted to axial force by ball screw, and the vascular specimen is stretched axially. The tension is measured by a load cell, and the displacement is recorded by a grating displacement sensor.FindingsAccording to the results of calibration experiment and stability experiment, the linearity error of the system is 0.251, the hysteresis error is 0.047, the repeatability error is 0.185, the comprehensive error is 0.315 and the standard deviation of the output is less than 0.01 N. A test of animal vascular mechanical properties was carried out, and the results are consistent with the theory.Originality/valueThis apparatus is designed to measure biomechanical properties of blood vessels, and the results of experiments indicate that it is stable and reliable. This work is valuable for studying vascular disease and testing artificial blood vessels.

Journal

Sensor ReviewEmerald Publishing

Published: Jul 21, 2020

Keywords: Fatigue test; Mechanical test platform; Tensile test; Vascular mechanical properties