Developmental validation of the PowerPlex ® 16 HS System: An improved 16-locus fluorescent STR multiplex

Developmental validation of the PowerPlex ® 16 HS System: An improved 16-locus fluorescent STR... STR multiplexes remain the cornerstone of genotyping forensic samples. The PowerPlex ® 16 HS System contains the core CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX, and vWA. Additional loci amplified in the multiplex reaction are the sex-determinant locus, amelogenin, and two pentanucleotide STR loci, Penta D and Penta E. The PowerPlex ® 16 HS System is an updated version of the PowerPlex 16 ® System; while the primers and dyes remain unchanged, it introduces an enhanced buffer system that includes hot-start Taq DNA polymerase and ensures robust performance. Due to the modification of the reaction mix, a multi-laboratory developmental validation study was completed to document performance capabilities and limitations for the revised assay. Data within this validation was generated by eight laboratories and served as the basis for the following conclusions: genotyping of single-source samples was consistent across a large range of template DNA concentrations with most laboratories obtaining complete profiles at 62.5 pg. Mixture analyses showed that over 90% of minor alleles were detected at 1:9 ratios. Optimum amplification cycle number was ultimately dependent on the sensitivity of the detection instrument and could be adjusted to accommodate a range of DNA template concentrations. Reaction conditions including volume and annealing temperature as well as the concentrations of primers, Taq DNA polymerase, and magnesium were shown to be optimal and able to withstand moderate variations without affecting multiplexed STR amplification. Finally, data from non-probative samples and concordance studies showed consistent results when comparing the PowerPlex ® 16 HS System with the PowerPlex ® 16 System as well as other commercially available systems. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Forensic Science International: Genetics Elsevier

Developmental validation of the PowerPlex ® 16 HS System: An improved 16-locus fluorescent STR multiplex

Loading next page...
 
/lp/elsevier/developmental-validation-of-the-powerplex-16-hs-system-an-improved-16-ntC7zaCKYp
Publisher site
See Article on Publisher Site

Abstract

STR multiplexes remain the cornerstone of genotyping forensic samples. The PowerPlex ® 16 HS System contains the core CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX, and vWA. Additional loci amplified in the multiplex reaction are the sex-determinant locus, amelogenin, and two pentanucleotide STR loci, Penta D and Penta E. The PowerPlex ® 16 HS System is an updated version of the PowerPlex 16 ® System; while the primers and dyes remain unchanged, it introduces an enhanced buffer system that includes hot-start Taq DNA polymerase and ensures robust performance. Due to the modification of the reaction mix, a multi-laboratory developmental validation study was completed to document performance capabilities and limitations for the revised assay. Data within this validation was generated by eight laboratories and served as the basis for the following conclusions: genotyping of single-source samples was consistent across a large range of template DNA concentrations with most laboratories obtaining complete profiles at 62.5 pg. Mixture analyses showed that over 90% of minor alleles were detected at 1:9 ratios. Optimum amplification cycle number was ultimately dependent on the sensitivity of the detection instrument and could be adjusted to accommodate a range of DNA template concentrations. Reaction conditions including volume and annealing temperature as well as the concentrations of primers, Taq DNA polymerase, and magnesium were shown to be optimal and able to withstand moderate variations without affecting multiplexed STR amplification. Finally, data from non-probative samples and concordance studies showed consistent results when comparing the PowerPlex ® 16 HS System with the PowerPlex ® 16 System as well as other commercially available systems.

Journal

Forensic Science International: GeneticsElsevier

Published: Jul 1, 2010

References

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 18 million articles from more than
15,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Search

Query the DeepDyve database, plus search all of PubMed and Google Scholar seamlessly

Organize

Save any article or search result from DeepDyve, PubMed, and Google Scholar... all in one place.

Access

Get unlimited, online access to over 18 million full-text articles from more than 15,000 scientific journals.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve

Freelancer

DeepDyve

Pro

Price

FREE

$49/month
$360/year

Save searches from
Google Scholar,
PubMed

Create folders to
organize your research

Export folders, citations

Read DeepDyve articles

Abstract access only

Unlimited access to over
18 million full-text articles

Print

20 pages / month

PDF Discount

20% off