Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Estimation of hydrolysis parameters in full‐scale anerobic digesters

Estimation of hydrolysis parameters in full‐scale anerobic digesters In hydrolysis‐limited anerobic systems, the key parameters describing degradation are degradability extent (fd), and the lumped apparent first order coefficient (khyd). These are often measured in biological methane potential (BMP) tests. Using modern techniques, it should also be possible to estimate these parameters in full‐scale systems, especially where inputs are dynamic. In this study, we evaluated fd and khyd values and uncertainty based on nonlinear parameter estimation from (i) BMP tests and (ii) effluent gas and solids from two full‐scale digesters fed with highly variable feed flows and concentrations (up to 6 kg COD m−3 day−1). The substrate was thermally hydrolyzed activated sludge, and the inoculum for BMP tests was from the full‐scale digesters. While identifiability of both parameters in the BMP tests was generally good, only fd could be well identified using continuous data. For khyd using continuous data, normally only a lower limit could be found (upper was unbounded). In addition, parameters as estimated on different outputs (VS and gasflow) and two different digesters were consistent, with an fd value of 0.45–0.55, and a khyd value of >5 day−1. Gradual changes in fd over the 450 days could be related to upstream changes. fd values as estimated in BMP tests were consistent (if conservative) with continuous estimates, with a fd in BMP of 0.4–0.5. khyd values were an order of magnitude lower (0.15–0.25 day−1 vs. >5 day−1), and this translated to very poor model performance when BMP‐estimated values were used in the continuous model. This means that while BMP testing may be used for project feasibility analysis, values obtained should not be used for dynamic modeling. The parameter confidence regions found were highly nonlinear, especially for continuous systems, indicating that iterative or sampling techniques are required for an estimate of real parameter uncertainty. Biotechnol. Bioeng. 2009;102: 1513–1520. © 2008 Wiley Periodicals, Inc. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Biotechnology and Bioengineering Wiley

Estimation of hydrolysis parameters in full‐scale anerobic digesters

Loading next page...
 
/lp/wiley/estimation-of-hydrolysis-parameters-in-full-scale-anerobic-digesters-yErrJGLRqL

References (11)

Publisher
Wiley
Copyright
Copyright © 2009 Wiley Periodicals, Inc., A Wiley Company
ISSN
0006-3592
eISSN
1097-0290
DOI
10.1002/bit.22163
pmid
18988267
Publisher site
See Article on Publisher Site

Abstract

In hydrolysis‐limited anerobic systems, the key parameters describing degradation are degradability extent (fd), and the lumped apparent first order coefficient (khyd). These are often measured in biological methane potential (BMP) tests. Using modern techniques, it should also be possible to estimate these parameters in full‐scale systems, especially where inputs are dynamic. In this study, we evaluated fd and khyd values and uncertainty based on nonlinear parameter estimation from (i) BMP tests and (ii) effluent gas and solids from two full‐scale digesters fed with highly variable feed flows and concentrations (up to 6 kg COD m−3 day−1). The substrate was thermally hydrolyzed activated sludge, and the inoculum for BMP tests was from the full‐scale digesters. While identifiability of both parameters in the BMP tests was generally good, only fd could be well identified using continuous data. For khyd using continuous data, normally only a lower limit could be found (upper was unbounded). In addition, parameters as estimated on different outputs (VS and gasflow) and two different digesters were consistent, with an fd value of 0.45–0.55, and a khyd value of >5 day−1. Gradual changes in fd over the 450 days could be related to upstream changes. fd values as estimated in BMP tests were consistent (if conservative) with continuous estimates, with a fd in BMP of 0.4–0.5. khyd values were an order of magnitude lower (0.15–0.25 day−1 vs. >5 day−1), and this translated to very poor model performance when BMP‐estimated values were used in the continuous model. This means that while BMP testing may be used for project feasibility analysis, values obtained should not be used for dynamic modeling. The parameter confidence regions found were highly nonlinear, especially for continuous systems, indicating that iterative or sampling techniques are required for an estimate of real parameter uncertainty. Biotechnol. Bioeng. 2009;102: 1513–1520. © 2008 Wiley Periodicals, Inc.

Journal

Biotechnology and BioengineeringWiley

Published: Apr 1, 2009

Keywords: hydrolysis; activated sludge; SRT; anerobic; thermal hydrolysis; ADM1

There are no references for this article.