A test object and criteria for high resolution electron microscopy

A test object and criteria for high resolution electron microscopy The desirability and requirements for a specimen capable of testing the resolving power and other image characteristics of an electron microscope are discussed in detail. In this discussion, the underlying diffraction phenomena are particularly utilized. A partially graphitized carbon black is shown to satisfy the requirements extremely well and constitutes an easily prepared specimen for conducting tests of image quality in the molecular size range. The structure of the test object is known in detail with the result that readily interpretable phase contrast images are obtained. Micrographs illustrating the use of the 3.4 Å (002) spacing for magnification calibration, astigmatism and asymmetry check as well as resolving power are exhibited. The second order c‐spacing of 1.7 Å is occasionally found in an image. The micrographs shown herein were taken with two different electron microscopes by different operators obtaining the same structural detail in the images. It is concluded that the carbon black test object offers the best possibilities for evaluating image performance of any specimen yet suggested. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Applied Crystallography Wiley

A test object and criteria for high resolution electron microscopy

Loading next page...
 
/lp/wiley/a-test-object-and-criteria-for-high-resolution-electron-microscopy-mz0ZU8Bz5y

References (2)

Publisher
Wiley
Copyright
Copyright © 1968 Wiley Subscription Services, Inc., A Wiley Company
ISSN
1600-5767
eISSN
1600-5767
DOI
10.1107/S0021889868004930
Publisher site
See Article on Publisher Site

Abstract

The desirability and requirements for a specimen capable of testing the resolving power and other image characteristics of an electron microscope are discussed in detail. In this discussion, the underlying diffraction phenomena are particularly utilized. A partially graphitized carbon black is shown to satisfy the requirements extremely well and constitutes an easily prepared specimen for conducting tests of image quality in the molecular size range. The structure of the test object is known in detail with the result that readily interpretable phase contrast images are obtained. Micrographs illustrating the use of the 3.4 Å (002) spacing for magnification calibration, astigmatism and asymmetry check as well as resolving power are exhibited. The second order c‐spacing of 1.7 Å is occasionally found in an image. The micrographs shown herein were taken with two different electron microscopes by different operators obtaining the same structural detail in the images. It is concluded that the carbon black test object offers the best possibilities for evaluating image performance of any specimen yet suggested.

Journal

Journal of Applied CrystallographyWiley

Published: Apr 2, 1968

There are no references for this article.