Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Erratum: Weak values in nonideal spin measurements: An exact treatment beyond the asymptotic regime ( Phys. Rev. A 85 , 022122 ( 2012 ) )

Erratum: Weak values in nonideal spin measurements: An exact treatment beyond the asymptotic... PHYSICAL REVIEW A 87, 049901(E) (2013) A. K. Pan and A. Matzkin (Received 18 March 2013; published 2 April 2013) DOI: 10.1103/PhysRevA.87.049901 PACS number(s): 03.65.Ta, 99.10.Cd In the last paragraph of Sec. III F (page 6), in which recent works dealing with the same topic are briefly discussed, we mistakenly omitted mention of the article by Di Lorenzo and Egues [1]. That paper examines the effect of the detector dynamics on the weak value. While the focus of Ref. [1] is on the contribution of the imaginary component of the weak value to the observable average inferred from the probe, Eq. (14) of that paper gives the probe dynamics for spin measurements without restricting the coupling or the probe states to the weak measurement regime, encompassing Eqs. (29) and (30) of our work obtained under the same assumptions. [1] A. Di Lorenzo and J. Carlos Egues, Phys. Rev. A 77, 042108 (2008). 1050-2947/2013/87(4)/049901(1) 049901-1 ©2013 American Physical Society http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Physical Review A American Physical Society (APS)

Erratum: Weak values in nonideal spin measurements: An exact treatment beyond the asymptotic regime ( Phys. Rev. A 85 , 022122 ( 2012 ) )

Physical Review A , Volume 87 (4) – Apr 2, 2013

Loading next page...
 
/lp/american-physical-society-aps/erratum-weak-values-in-nonideal-spin-measurements-an-exact-treatment-dXxwmfvJf8

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
American Physical Society (APS)
Copyright
©2013 American Physical Society
ISSN
1050-2947
DOI
10.1103/PhysRevA.87.049901
Publisher site
See Article on Publisher Site

Abstract

PHYSICAL REVIEW A 87, 049901(E) (2013) A. K. Pan and A. Matzkin (Received 18 March 2013; published 2 April 2013) DOI: 10.1103/PhysRevA.87.049901 PACS number(s): 03.65.Ta, 99.10.Cd In the last paragraph of Sec. III F (page 6), in which recent works dealing with the same topic are briefly discussed, we mistakenly omitted mention of the article by Di Lorenzo and Egues [1]. That paper examines the effect of the detector dynamics on the weak value. While the focus of Ref. [1] is on the contribution of the imaginary component of the weak value to the observable average inferred from the probe, Eq. (14) of that paper gives the probe dynamics for spin measurements without restricting the coupling or the probe states to the weak measurement regime, encompassing Eqs. (29) and (30) of our work obtained under the same assumptions. [1] A. Di Lorenzo and J. Carlos Egues, Phys. Rev. A 77, 042108 (2008). 1050-2947/2013/87(4)/049901(1) 049901-1 ©2013 American Physical Society

Journal

Physical Review AAmerican Physical Society (APS)

Published: Apr 2, 2013

There are no references for this article.