Validation of the Six Sigma Z-score for the quality assessment of clinical laboratory timeliness

Validation of the Six Sigma Z-score for the quality assessment of clinical laboratory timeliness AbstractBackground:The International Federation of Clinical Chemistry and Laboratory Medicine has introduced in recent times the turnaround time (TAT) as mandatory quality indicator for the postanalytical phase. Classic TAT indicators, namely, average, median, 90th percentile and proportion of acceptable test (PAT), are in use since almost 40 years and to date represent the mainstay for gauging the laboratory timeliness. In this study, we investigated the performance of the Six Sigma Z-score, which was previously introduced as a device for the quantitative assessment of timeliness.Methods:A numerical simulation was obtained modeling the actual TAT data set using the log-logistic probability density function. Five thousand replicates for each size of the artificial TAT random sample (n=20, 50, 250 and 1000) were generated, and different laboratory conditions were simulated manipulating the PDF in order to generate more or less variable data. The Z-score and the classic TAT indicators were assessed for precision (%CV), robustness toward right-tailing (precision at different sample variability), sensitivity and specificity.Results:Z-score showed sensitivity and specificity comparable to PAT (≈80% with n≥250), but superior precision that ranged within 20% by moderately small sized samples (n≥50); furthermore, Z-score was less affected by the value of the cutoff used for setting the acceptable TAT, as well as by the sample variability that reflected into the magnitude of right-tailing.Conclusions:The Z-score was a valid indicator of laboratory timeliness and a suitable device to improve as well as to maintain the achieved quality level. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Clinical Chemistry and Laboratory Medicine (CCLM) de Gruyter

Validation of the Six Sigma Z-score for the quality assessment of clinical laboratory timeliness

Loading next page...
 
/lp/degruyter/validation-of-the-six-sigma-z-score-for-the-quality-assessment-of-XoT7fehCwx
Publisher
De Gruyter
Copyright
©2018 Walter de Gruyter GmbH, Berlin/Boston
ISSN
1437-4331
eISSN
1437-4331
D.O.I.
10.1515/cclm-2017-0642
Publisher site
See Article on Publisher Site

Abstract

AbstractBackground:The International Federation of Clinical Chemistry and Laboratory Medicine has introduced in recent times the turnaround time (TAT) as mandatory quality indicator for the postanalytical phase. Classic TAT indicators, namely, average, median, 90th percentile and proportion of acceptable test (PAT), are in use since almost 40 years and to date represent the mainstay for gauging the laboratory timeliness. In this study, we investigated the performance of the Six Sigma Z-score, which was previously introduced as a device for the quantitative assessment of timeliness.Methods:A numerical simulation was obtained modeling the actual TAT data set using the log-logistic probability density function. Five thousand replicates for each size of the artificial TAT random sample (n=20, 50, 250 and 1000) were generated, and different laboratory conditions were simulated manipulating the PDF in order to generate more or less variable data. The Z-score and the classic TAT indicators were assessed for precision (%CV), robustness toward right-tailing (precision at different sample variability), sensitivity and specificity.Results:Z-score showed sensitivity and specificity comparable to PAT (≈80% with n≥250), but superior precision that ranged within 20% by moderately small sized samples (n≥50); furthermore, Z-score was less affected by the value of the cutoff used for setting the acceptable TAT, as well as by the sample variability that reflected into the magnitude of right-tailing.Conclusions:The Z-score was a valid indicator of laboratory timeliness and a suitable device to improve as well as to maintain the achieved quality level.

Journal

Clinical Chemistry and Laboratory Medicine (CCLM)de Gruyter

Published: Mar 28, 2018

There are no references for this article.

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 12 million articles from more than
10,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Unlimited reading

Read as many articles as you need. Full articles with original layout, charts and figures. Read online, from anywhere.

Stay up to date

Keep up with your field with Personalized Recommendations and Follow Journals to get automatic updates.

Organize your research

It’s easy to organize your research with our built-in tools.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve Freelancer

DeepDyve Pro

Price
FREE
$49/month

$360/year
Save searches from
Google Scholar,
PubMed
Create lists to
organize your research
Export lists, citations
Read DeepDyve articles
Abstract access only
Unlimited access to over
18 million full-text articles
Print
20 pages/month
PDF Discount
20% off