Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Droop based Demand Dispatch for Residential Loads in Smart Grid Application

Droop based Demand Dispatch for Residential Loads in Smart Grid Application AbstractAggregated loads play a significant role in maintaining the frequency of power system when the generation is not able to follow frequency deviations. An automatic Demand Dispatch (DD) enables the power system to employ the aggregated loads for balancing demand and supply. In this paper, a Demand Side Frequency Droop (DSFD) has been proposed which provides ancillary service to the grid and maintains the frequency of the power system when the generation system is not capable of following the demand. At the time of a frequency fall/rise, Balancing Authority (BA) can detect aggregated load or group of aggregated loads that have power consumption above or below their standard maximum/minimum consumption levels. Then, the BA issues a droop-based signal to the relevant aggregator. Afterwards, the DSFD will be implemented in the aggregator or the group of aggregators to specify the required power consumption amount for bringing the frequency back to its rated level. Subsequently, this signal will be sent to the Appliance Management Unit (AMU) at each participating house. The AMU sends the signal in the form of deferral or interruptible commands to the appliances depending on the priority, availability and the specification of the appliances. It will be demonstrated that the proposed DSFD control maintains the frequency of the power system within a specified range. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png International Journal of Emerging Electric Power Systems de Gruyter

Droop based Demand Dispatch for Residential Loads in Smart Grid Application

Loading next page...
 
/lp/degruyter/droop-based-demand-dispatch-for-residential-loads-in-smart-grid-a0o901drg8

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
de Gruyter
Copyright
© 2018 Walter de Gruyter GmbH, Berlin/Boston
ISSN
1553-779X
eISSN
1553-779X
DOI
10.1515/ijeeps-2017-0218
Publisher site
See Article on Publisher Site

Abstract

AbstractAggregated loads play a significant role in maintaining the frequency of power system when the generation is not able to follow frequency deviations. An automatic Demand Dispatch (DD) enables the power system to employ the aggregated loads for balancing demand and supply. In this paper, a Demand Side Frequency Droop (DSFD) has been proposed which provides ancillary service to the grid and maintains the frequency of the power system when the generation system is not capable of following the demand. At the time of a frequency fall/rise, Balancing Authority (BA) can detect aggregated load or group of aggregated loads that have power consumption above or below their standard maximum/minimum consumption levels. Then, the BA issues a droop-based signal to the relevant aggregator. Afterwards, the DSFD will be implemented in the aggregator or the group of aggregators to specify the required power consumption amount for bringing the frequency back to its rated level. Subsequently, this signal will be sent to the Appliance Management Unit (AMU) at each participating house. The AMU sends the signal in the form of deferral or interruptible commands to the appliances depending on the priority, availability and the specification of the appliances. It will be demonstrated that the proposed DSFD control maintains the frequency of the power system within a specified range.

Journal

International Journal of Emerging Electric Power Systemsde Gruyter

Published: Apr 6, 2018

References