Harmonisation of serum dihydrotestosterone analysis: establishment of an external quality assurance program

Harmonisation of serum dihydrotestosterone analysis: establishment of an external quality... AbstractBackground:Serum dihydrotestosterone (DHT) is an important analyte for the clinical assessment of disorders of sex development. It is also reportedly a difficult analyte to measure. Currently, there are significant gaps in the standardisation of this analyte, including no external quality assurance (EQA) program available worldwide to allow for peer review performance of DHT. We therefore proposed to establish a pilot EQA program for serum DHT.Methods:DHT was assessed in the 2015 Royal College of Pathologists of Australasia Quality Assurance Programs’ Endocrine program material. The material’s target (i.e. “true”) values were established using a measurement procedure based on isotope dilution gas chromatography (GC) tandem mass spectrometry (MS/MS). DHT calibrator values were based on weighed values of pure DHT material (>97.5% purity) from Sigma. The allowable limits of performance (ALP) were established as ±0.1 up to 0.5 nmol/L and ±15% for targets >0.5 nmol/L.Results:Target values for the six levels of RCPAQAP material for DHT ranged from 0.02 to 0.43 nmol/L (0.01–0.12 ng/mL). The material demonstrated linearity across the six levels. There were seven participating laboratories for this pilot study. Results of the liquid chromatography (LC) MS/MS methods were within the ALP; whereas the results from the immunoassay methods were consistently higher than the target values and outside the ALP.Conclusions:This report provides the first peer comparison of serum DHT measured by mass spectrometry (MS) and immunoassay laboratories. Establishment of this program provides one of the pillars to achieve method harmonisation. This supports accurate clinical decisions where DHT measurement is required. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Clinical Chemistry and Laboratory Medicine (CCLM) de Gruyter

Harmonisation of serum dihydrotestosterone analysis: establishment of an external quality assurance program

Loading next page...
 
/lp/de-gruyter/harmonisation-of-serum-dihydrotestosterone-analysis-establishment-of-s3t4FlM4o9
Publisher
de Gruyter
Copyright
©2017 Walter de Gruyter GmbH, Berlin/Boston
ISSN
1437-4331
eISSN
1437-4331
DOI
10.1515/cclm-2016-0394
pmid
27701133
Publisher site
See Article on Publisher Site

Abstract

AbstractBackground:Serum dihydrotestosterone (DHT) is an important analyte for the clinical assessment of disorders of sex development. It is also reportedly a difficult analyte to measure. Currently, there are significant gaps in the standardisation of this analyte, including no external quality assurance (EQA) program available worldwide to allow for peer review performance of DHT. We therefore proposed to establish a pilot EQA program for serum DHT.Methods:DHT was assessed in the 2015 Royal College of Pathologists of Australasia Quality Assurance Programs’ Endocrine program material. The material’s target (i.e. “true”) values were established using a measurement procedure based on isotope dilution gas chromatography (GC) tandem mass spectrometry (MS/MS). DHT calibrator values were based on weighed values of pure DHT material (>97.5% purity) from Sigma. The allowable limits of performance (ALP) were established as ±0.1 up to 0.5 nmol/L and ±15% for targets >0.5 nmol/L.Results:Target values for the six levels of RCPAQAP material for DHT ranged from 0.02 to 0.43 nmol/L (0.01–0.12 ng/mL). The material demonstrated linearity across the six levels. There were seven participating laboratories for this pilot study. Results of the liquid chromatography (LC) MS/MS methods were within the ALP; whereas the results from the immunoassay methods were consistently higher than the target values and outside the ALP.Conclusions:This report provides the first peer comparison of serum DHT measured by mass spectrometry (MS) and immunoassay laboratories. Establishment of this program provides one of the pillars to achieve method harmonisation. This supports accurate clinical decisions where DHT measurement is required.

Journal

Clinical Chemistry and Laboratory Medicine (CCLM)de Gruyter

Published: Mar 1, 2017

There are no references for this article.

You’re reading a free preview. Subscribe to read the entire article.


DeepDyve is your
personal research library

It’s your single place to instantly
discover and read the research
that matters to you.

Enjoy affordable access to
over 18 million articles from more than
15,000 peer-reviewed journals.

All for just $49/month

Explore the DeepDyve Library

Search

Query the DeepDyve database, plus search all of PubMed and Google Scholar seamlessly

Organize

Save any article or search result from DeepDyve, PubMed, and Google Scholar... all in one place.

Access

Get unlimited, online access to over 18 million full-text articles from more than 15,000 scientific journals.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve

Freelancer

DeepDyve

Pro

Price

FREE

$49/month
$360/year

Save searches from
Google Scholar,
PubMed

Create folders to
organize your research

Export folders, citations

Read DeepDyve articles

Abstract access only

Unlimited access to over
18 million full-text articles

Print

20 pages / month

PDF Discount

20% off