Dynamic properties of hot-wire anemometric measurement circuits in the aspect of measurements in mine conditions / Właściwości dynamiczne termoanemometrycznych układów pomiarowych w aspekcie pomiarów w warunkach kopalnianych

Dynamic properties of hot-wire anemometric measurement circuits in the aspect of measurements in... Arch. Min. Sci., Vol. 57 (2012), No 3, p. 699­714 Electronic version (in color) of this paper is available: http://mining.archives.pl DOI 10.2478/v10267-012-0045-y PAWEL JAMRÓZ*, PAWEL LIGZA*, KATARZYNA SOCHA* DYNAMIC PROPERTIES OF HOT-WIRE ANEMOMETRIC MEASUREMENT CIRCUITS IN THE ASPECT OF MEASUREMENTS IN MINE CONDITIONS WLACIWOCI DYNAMICZNE TERMOANEMOMETRYCZNYCH UKLADÓW POMIAROWYCH W ASPEKCIE POMIARÓW W WARUNKACH KOPALNIANYCH The use of measurement apparatus under conditions which differ significantly from those under which the apparatus was adjusted carries the risk of altering the previously determined measurement characteristics. This is of special concern in the case of apparatus which is sensitive to external measurement conditions. Advanced measurement systems are equipped with algorithms which allow the negative effect of unstable environmental conditions on their static characteristics to be compensated for. Meanwhile, the problem of altered dynamic properties of such systems is often neglected. This paper presents a model study in which the effect of variable operational conditions on dynamic response of hot-wire anemometric measurement system in the case of simulated mine flows was investigated. A mathematical model of measurement system able to compensate the negative effect of changes in flow velocity and configuration of measurement apparatus itself on its dynamic properties was developed and investigated. Based on conducted experiments, we have developed an automatic regulation algorithm enabling the transmission band of measurement apparatus to be optimized for measurement conditions prevailing in mine environment. Keywords: measurements of flow phenomena, transmission band, limiting frequency, hot-wire anemometric measurement systems Stosowanie aparatury pomiarowej w warunkach rónych od warunków, w których aparatura ta byla adjustowana niesie ze sob ryzyko zmian wyznaczonych wczeniej charakterystyk pomiarowych. Dotyczy to w szczególnoci aparatury wraliwej na zewntrzne czynniki pomiarowe. Zaawansowane systemy pomiarowe wyposaa si w algorytmy pozwalajce na kompensacj negatywnego oddzialywania zmiennych warunków rodowiskowych glównie na charakterystyki statyczne. Pomija si czsto przy tym problem zmian wlaciwoci dynamicznych systemów. W artykule przedstawiono modelowe badania wplywu zmiennych warunków uytkowania na odpowied dynamiczn termoanemometrycznego systemu pomiarowego w warunkach pomiarów symulowanych przeplywów kopalnianych. Opracowano i przebadano symulacyjnie matematyczny model ukladu pomiarowego zdolnego do kompensacji negatywnego wplywu * STRATA MECHANICS RESEARCH INSTITUTE OF THE POLISH ACADEMY OF SCIENCES, UL. REYMONTA 27, 30-059 KRAKÓW, POLAND zmian prdkoci przeplywu oraz konfiguracji aparatury pomiarowej na jej wlaciwoci dynamiczne. Na podstawie przeprowadzonych bada stworzono algorytm automatycznej regulacji pozwalajcy na optymalizacj pasma przenoszenia aparatury pomiarowej w warunkach pomiarów w rodowisku kopalnianym. Slowa kluczowe: pomiary zjawisk przeplywowych, pasmo przenoszenia, czstotliwo graniczna, termoanemometryczne uklady pomiarowe 1. Introduction Recently, the development of hot-wire anemometric measurement methods enabled their use not only under precisely specified laboratory conditions, but also in measurement systems which operate in significantly diversified measurement environments. An example of such application is given by measurements performed in mines, where the hot-wire anemometric methods are used to perform measurements of flow velocity profiles in mine galleries (Krawczyk et al., 2011). Among other things, such measurements enable the verification of models of mine ventilation systems with ever-increasing complexity, which for example give consideration to micro-scale phenomena related to measurements of flow turbulence phenomena occurring in near-wall layer (Ligza et al., 2009). Fig. 1. Hot-wire anemometric measurements of ventilation in mine conditions The turbulence is defined as a phenomenon which is random in time and space, and for which the formula determining its value in any given time instant is not possible to be written. Only the probability of occurrence of individual values may be determined for such signal. The analysis of turbulence as a random signal, all characteristic physical quantities of which are of variability random in time and space is based mainly on Reynolds hypothesis. According to this hypothesis, the fluid movement can be treated as a superposition of average and fluctuation movement (Elsner & Drobniak, 1995). Such an analysis is possible only on the basis of empirical results, which may be obtained with the use of hot-wire anemometers. During measurements with the use of hot-wire anemometric measurement systems, problems related to change of dynamic characteristic of hot-wire anemometric systems are often encountered. Their limiting frequency depends on configuration of electronic measurement systems and the environment in which they are being utilized (Watmuff, 1995; Khoo, 1998; Chew et al., 1998; Li, 2005). This comprises one of current scientific problems the solution of which will allow for measurements of random phenomena in turbulent flows to be realized using apparatuses with known metrological properties. It will especially facilitate precise and reliable analysis of measurement results. 2. Dynamic properties of hot-wire anemometric measurement systems Dynamic response of a hot-wire anemometer is related to its voltage or current response to changing velocity and temperature of flowing medium in which the sensor is placed. In order to perform precise determination of such response it would however be necessary to generate the periodically changing velocity field. Nevertheless, with respect to the impossibility of generating such harmonically precisely specified variable fields of flow velocity, such experiments are rather impossible to be performed. Due to this reason, investigations of dynamics of hot-wire anemometric systems are performed with the use of a generator of periodically changing current signal (rectangular wave) incorporated into a hot-wire anemometric circuit. It simulates a step change of velocity generating a specified voltage response which may allows to determine the dynamic properties of the system. For given measurement conditions and given configuration of the hot-wire anemometer, control parameters of measurement system may be adjusted in a way, such that the response of the system to rectangular signal was fifteen percent undershoot. For such settings, the time t is specified as the time at which the system's response reaches 3% of its maximum value. Figure 2 presents the proper response of the hot-wire anemometer obtained with the frequency test, based on which the transmission band of the whole system fc may be assessed according to relationship 1 (Freymuth, 1977). fc = 1 1.3 ×D t (1) Fig. 2. Dynamic characteristic of the hot-wire anemometer The response of the hot-wire anemometric system concerns not only the reaction of the sensor itself to changing flow conditions, but also the reaction of the entire measurement system. The system's dynamics is related not only to physical properties of measuring wire (Jamróz, 2008, 2011) and its operational conditions, but also to characteristics of the apparatus itself, such as electronic parameters of measuring channel and the way in which the signals are brought to/from the measurement probe. Therefore it is necessary that the whole signal processing line be subject to dynamic analysis. The dynamics of the whole system depends on its individual elements. Alterations in any of them results in changes of ideal characteristics of dynamic response of the whole measurement system. Performing measurements by means of hot-wire anemometric apparatus under operational conditions which differ significantly from laboratory ones in which the apparatus was adjusted to ensure its maximum limiting frequency, the system must be capable of adjustment in actual measurement conditions. The hot-wire anemometer capable of automatic self-regulation of its own dynamic properties depending on conditions under which it has to operate would present an optimal solution. In the next section of this study, presented is the simulation study of the effect of external measurement factors on limiting frequency of modelled hot-wire anemometric measurement system developed on the basis of the concept of system allowing for negative effects of external factors on whole system's transmission band to be compensated for. 3. A model of hot-wire anemometric measurement system A simplified scheme of the hot-wire anemometer with potentiometric adjustment of its dynamic properties is presented in Figure 3 (Ligza, 2007). Such a system consists of velocity measurement sensor RS incorporated in one of the branches of resistance bridge and an operational amplifier working in the feedback loop. The sensor together with the resistor RI and the potentiometer P2 comprise a resistance bridge which operates as the resistance comparator system. Fig. 3. The scheme of hot-wire anemometer with potentiometric adjustment of its dynamic properties Dynamic properties of the system are adjusted through incorporating two potentiometers between the upper point and the ground point of the resistance bridge. Sliders of these potentiometers are connected to two-terminal RC network, the terminals of which are appropriately connected to inverting and non-inverting input of measuring amplifier. According to the main concept of the system, adjustment by the potentiometer P1 is to give the possibility to obtain the stable operation of the system following initial optimization of its transmission band. Adjustment by the potentiometer P2, on the other hand, should allow for final optimization of transmission band of the whole system to be obtained. Simulated step changes of the velocity are realized by means of adjusting the offset voltage of operational amplifier U0. For such a system, mathematical model (2) was developed, based on which the series of simulations aimed to determine the influence of external measurement conditions on system's transmission band can possibly be performed. Moreover, it also allows for the possibility of compensation of these effects to be explored. dUC 1 dt æ P RS 12 UA ç R + RI èP + P 11 12 = C1 (R1 + R3) æ ç - U C1 è dUC 2 dt æ P22 PB æ UA ç ç - UC 2 P21 + P22 PA + PB è è = C2 (R2 + R4 ) dUA 1 = - (UA + kA UE ) t dt (2) æ P R R æ R PB æ æ P22 12 UA ç + 1 + 2 ç - UC1 UA ç ç - UC2 A è P11 + P12 R3 R + R I è è P21 + P22 R4 P + PB è UE = + U0 R1 R2 +1 +1 R3 R4 2 dRS ( RS + RI ) = dt UA RS - (AS + BS V S) ( RS - RM ) CS RB RA t = kA RA C , kA = A In this model, consideration is given to dependences describing the hot-wire anemometric sensor allowing for its dynamics as well, with the sensor being described by an instantaneous value of resistance RS and parameters AS, BS, nS and cS which specify the characteristics of the wire in the function of velocity V (Ligza, 2001). Moreover, state variables related to instantaneous values of variable voltages U1 and UC2 as well as to controller circuit UA were specified. 4. The effect of external factors on limiting frequency of the hot-wire anemometer Evaluation of the effect of external factors was performed based on the above presented model of hot-wire anemometer (2). Simulation testing was performed in the Matlab environment utilizing the ode45 function enabling the calculation of differential equations. In the course of simulation, the dynamic response of measurement system in the form of instantaneous values of voltage across the wire URS was determined. The values of parameters used in simulations are presented in Tables 1, 2 and 3. TABLE 1 Parameters of measurement probe containing the 3-um wire RM 5 TM K 293 S 1/K 3.33e-3 AS A2 2e-3 BS cS A2s 0.5e-6 nS 0.5 TABLE 2 s A2 m 0.5e-3 Parameters of measurement probe containing the 5-um wire RM 5 TM K 293 S 1/K 3.33e-3 AS A BS cS As 4e-6 nS 0.5 TABLE 3 4e-3 s A m 2e-3 Exemplary parameters of operational amplifier RA 1e6 A s 15e-3 kA 1e6 TABLE 4 Values of coefficients of the model of hot-wire anemometer RI 10 P 10e3 P1 10e3 P2 10e3 C1 nF 47 C2 pF 350 R1 1e3 R2 100 R3 100 R4 100 4.1. The effect of average flow velocity on dynamic response of the hot-wire anemometer Literature dealing with the dynamic analysis of hot-wire anemometric systems seems to point to strong dependence of limiting frequency of such systems on flow velocity. This dependence is attributable to changes of the intensity of heat exchange between the measuring wire and flowing medium. These changes influence also the nature of the dynamic response of the measurement systems itself. In order to emphasize the magnitude of the effect of flow velocity on limiting frequency of the system, a simulation in which the dynamic response of hot-wire anemometer was optimized for minimum velocity of 0.5 m/s was performed. As a result, the characteristic consistent with the one presented in Figure 2 was obtained. A model of sensor incorporating the measuring wire of 3 µm diameter was used in such simulation. Subsequently, increasing the flow velocity, changes in dynamic response of hot-wire anemometric measurement system were monitored. Results of the simulation are presented in Figure 4. Fig. 4. The effect of average flow velocity on dynamic response of the hot-wire anemometer Together with increasing velocity, the characteristics of dynamic response changes. The undershoot level increases and subsequent maxima occur in the signal of response, which adopts the nature of oscillatory response, leading to unstable operation of the whole measurement system. By default, the procedure of optimization of the dynamic response of hot-wire anemometer is carried out at high velocities. Thanks to this, it is possible to avoid the risk of obtaining the unstable oscillatory operation of measurement system when measurements at lower values of velocity are performed. Figure 5 shows the results of simulation, in which the response of the system optimized with respect to time was obtained for simulated flow velocity of 35 m/s. In this case, the limiting frequency of the system was determined to be equal to 79.76 kHz. In subsequent steps of the simulation, the velocity was gradually reduced to value as low as 0.5 m/s. As the velocity changes, the deformation of previously obtained ideally shaped characteristic of dynamic response of the system occurs, which is associated with deterioration of dynamic properties of the whole measurement system. In the case of the velocity of 15 m/s, the transmission band is maintained at the level of 62.93 kHz, nevertheless, in the case of the velocity of 0.5 m/s, this value decreases down to 43.75 kHz. Fig. 5. The effect of average flow velocity on dynamic response of the hot-wire anemometer 4.2. The probe type and the dynamics of the hot-wire anemometer While performing the measurements under conditions prevailing in mines, there is a high risk of damaging the hot-wire anemometric measurement probe in case of which it might become necessary to replace the sensor with another one. Each probe is characterized by its own individual parameters, such as the wire thickness or resistance. Simulative determination of the effect of changing the probe type on dynamics of the hot-wire anemometric measurement system was performed using the coefficients describing the models of 3-µm and 5-µm probes, presented in Tables 1 and 2, respectively. In the first phase, adjustment of the system was performed in a way which ensured the fastest possible time-response of the hot-wire anemometer equipped with the probe incorporating the 3-µm wire. Subsequently, the dynamic response of the system in which the 3-µm probe was replaced by a 5-µm one was recorded. Investigations were carried out at simulated flow velocity of 20 m/s. Results of the simulation are presented in Figure 6. On the basis of results of simulation, it is possible to conclude, that the change of the probe type results in characteristics of dynamic response of the system to be deformed considerably, such Probe 3 m 1.4 1.2 1 URS [V] URS [V] 0.8 0.6 0.4 0.2 0 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 Probe 5 m 0.5 t [s] 2 t [s] 6 x 10 Fig. 6. The probe type and dynamic response of the hot wire anemometer that they do not allow determining the system's dynamic properties. Conducting measurements of rapidly changing high-frequency phenomena utilizing the system with such characteristic of frequency response does not allow for accurate analysis of measurement results to be performed. In such a case, it is necessary to readjust the system in order to obtain optimal time characteristics of dynamic response of the measurement system. In successive simulation an evaluation of the effect that replacement of measurement probe with the other one of the very same type might potentially have on dynamics of the measurement system was performed. Hot-wire anemometric probes of the same type may differ from each other in values of their resistance. It is caused by the process of their production. An initially optimized dynamic response of the system equipped with the wire of 3 µm in diameter and resistance of 5 for TM = 293 K was analyzed in the simulation. In subsequent phases of investigations, the system's response given the changing resistance of the sensor was recorded. Results of the simulation are presented in Figure 7. Results of conducted simulation point to significant effect of measurement sensor's resistance on obtained transmission band of the whole measurement system. Increase in resistance by 0.3 above the initial value in the same temperature results in observable changes in characteristics of Probe 5 m RM= 5 0.51 URS [V] 0.505 0.5 0.495 0 0.5 t [s] Probe 5 m RM = 5.3 0.525 URS [V] 0.52 0.515 0.51 0.505 0 0.5 t [s] Probe 5 m RM = 5.6 0.54 URS [V] 0.53 0.52 0 0.5 t [s] 1 Fig. 7. The sensor's resistance and dynamic response of the hot wire anemometer dynamic response of the measurement system. These changes require fine adjustment of system's response to obtain optimal characteristics. Higher values of resistance lead to unstable operation of the whole system, which may end up in burn-through of the measurement sensor. 5. Adjustment of dynamic properties In the series of simulations conducted in order to explore the effects of external measurement factors on transmission band of the hot-wire anemometric measurement systems, their considerable effect on shaping of dynamic properties of measurement apparatus was demonstrated. Measurements under conditions prevailing in mines with the use of hot-wire anemometers require compensation methods allowing for negative effects of various factors not only on static characteristics of such devices but also on their dynamic characteristics, to be eliminated. Such compensation is provided by the system presented in Figure 2. In this system, the adjustment takes place by adopting appropriate settings of P1 and P2 potentiometers such that they would ensure that fifteen per cent undershoot in dynamic response of the system is obtained ­ Figure 2. The value of resistance of adjusting potentiometers, for which the system under investigation is characterized by stable yet slow dynamic response, has already been determined on the basis of results of performed model testing (Jamróz et al., 2010). Such response is being recorded for the lowest value of resistance P1 and maximum value of resistance P2. These values were used as starting points for adjustment algorithms. During simulation it was shown, that a series of pairs of settings of potentiometers P11 and P21 exists, for which the dynamic response of the system is consistent with optimum characteristics presented in Figure 2. Results of exemplary simulation illustrating the number of such pairs are presented in Figure 8, in which the black colour designates the areas in which the dynamic Fig. 8. Area of adjustment for flow velocities of 1 and 35 m/s response of the system is in line with the optimum characteristics. Simulations were carried out using the model of the 3-µm probe and for the velocity of 1 and 35 m/s. Areas of adjustment which ensure the obtainment of optimum characteristics of dynamic response of the system change depending on changes of actual values of external measurement factors as well as on electronic configuration of the measurement system itself. In the next part of the study the value of limiting frequency for the above mentioned simulation conditions was determined. Obtained results are presented in Figure 9. Fig. 9. Limiting frequency of the system for flow velocities of 1 and 35 m/s Performed simulation indicate, that the highest values of limiting frequency are obtained for those pairs of resistance of adjusting potentiometers in the case of which the values of resistances P11 and P21 are the highest and the lowest possible, respectively. These are the limiting values of resistance the exceeding of which results in unstable operation of the whole apparatus. 6. The algorithm of automatic optimization of transmission band Employment of digitally adjusted potentiometers allows for algorithm of automatic optimization to be performed. Development of algorithm of automatic adjustment is based on movements along the adjustment characteristic within areas, in which the obtained dynamic response of analyzed object is characterized by properties typical for model response of a hot-wire anemometric measurement system. The process of adjustment takes place until the optimum transmission band of measurement system is obtained. Such an algorithm allows for the widest possible transmission band to be obtained, nevertheless, in order to acquire the desirable effect, prolonged realization of such control process is required. Reduction of time of realization may be achieved by dividing the adjustment process into initial and final optimization steps. 6.1. Initial optimization The first phase of transmission band optimization is based on adjustment realized in several iterations, allowing for initially optimized transmission band of measurement system to be obtained in relatively short time. The principle of this method is presented in the form of an example of simulation performed for 3-µm sensor placed in the flow the velocity of which is equal to 1 m/s. The algorithm of initial optimization was developed on the basis of observation of the process of adjustment of the model and actual measurement system. It is based on adjustment starting from settings which guarantee stable yet slow dynamic response of the system (minimum and maximum values of P11 and P21 resistances, respectively) ­ see Figure 10. Fig. 10. Dynamic response of the model of hot-wire anemometer in the case of starting settings of adjusting potentiometers In the first phase of optimization, the value of resistance P11 is reduced to the level which allows for dynamic response of the measurement system characterized by occurrence of successive periods of over-regulation (with three local maximums) to be obtained ­ see Figure 11. During observations of the process of adjustment of model and actual measurement systems performed for different configurations and under various measurement conditions we noticed, that obtainment of such characteristic, with the starting value of resistance P21 maintained at fixed level at the same time, allows in the next step of adjustment process for the dynamic response of the system to be brought to a form consistent with the one showed in Figure 2. Fig. 11. Dynamic response of the model of hot-wire anemometer after the first phase of the algorithm of initial optimization of transmission band The final step of the adjustment procedure consists in the reduction of the value of resistance P21 to the level, in which the obtained characteristic of dynamic response of the system is as close to the model characteristic as possible. In the analyzed example, employment of automatic algorithm of initial optimization of transmission band allowed for obtainment of dynamic response P11 = 4.99 [k ] P21 = 3.64 [k ] Undershoot 15.07% fc = 52.45 kHz 0.28 0.279 0.278 0.277 URS [V] 0.276 0.275 0.274 0.273 0.272 0 0.5 t [s] 1 Fig. 12. Dynamic response of the model of hot-wire anemometer following the initial optimization of transmission band of the system with limiting frequency equal to 52.45 kHz. Although the obtained transmission band is not optimal for sensors incorporating 3-µm wires, it may still be considered sufficient for the majority of measurement situations. Presented adjustment procedure provides fast optimization of the system with respect to its dynamic properties. Manual optimization process however shows that even wider transmission band can possibly be obtained. It requires an additional adjustment of the system. 6.2. Final optimization Main assumption underlying the procedure of final optimization is to obtain the widest transmission band possible for different configurations of the system and under various measurement conditions. Optimization algorithm starts with the values of resistances P11 and P21 obtained as a result of the process of initial optimization. In the first step of final optimization, the resistance P11 becomes increased by a preset value p1. Subsequently, on the basis of performed measurement of dynamic response of the system, the value of over-regulation is checked. If the value is below 14.8%, the value p2 is reduced by a half and the resistance P21 becomes increased by a new value of p2. If obtained value of undershoot exceeds 15.2%, the resistance P21 becomes reduced by the value of p2. Following each such change of the value of resistance, a measurement of dynamic response of the system is performed. The process of such adjustment takes place until the response with undershoot falling within the range of 14.8÷15.2% is obtained. Acquirement of optimum transmission band is connected with the achievement of ideal characteristics of dynamic response showing only one maximum. Appearance of additional maximum signifies that the signal is over-regulated, therefore the level of this additional maximum in relation to the level of the steady signal may be considered as a criterion of final adjustment. If this criterion is fulfilled, the value of the resistance P1 is increased by p1 and the variable p2 is assigned its initial value. The algorithm of the final optimization ends, if it becomes impossible for subsequent value of P11 increased by the step p1 to find a matching value of the resistance P21 which would ensure the decrease of the magnitude of the additional maximum below the preset limit. It is a criterion, for which the obtained course of dynamic response of the hot-wire anemometer is considered optimal. 6.3. Evaluation of algorithm efficacy For algorithms described above the simulation studies allowing for evaluation of their efficacy in the case of adjustment in flows of different velocities were performed. Results for the 3-µm sensor are presented in Figure 13. As a result of initial optimization procedure, the limiting frequencies ranging from 52.45 kHz for velocity of 1 m/s to 82.83 kHz for 35 m/s were obtained. Conducting the procedure of final optimization of the transmission band leads to a significant improvement of obtained dynamics of the system, especially in the case of low flow velocities. In the case of flow velocity of 1 m/s, the limiting frequency of the system was increased by 13.99 kHz. In the case of higher velocities, achieved increase in limiting frequency was smaller. The value of limiting frequency for velocity of 35 m/s was increased by only 4.02 kHz. Analogous simulation study was performed also for a measurement sensor incorporating the wire of 5 µm in diameter, for which the limiting frequency was determined in a wide range of flow velocities. Alike the case of wire of 3 µm in diameter, the highest efficacy of the algorithm 90 80 70 60 fc [kHz] 50 40 30 20 10 0 0 5 10 15 20 v [m/s] final optimization initial optimization 25 30 35 Fig. 13. Results of the initial and final optimization of the transmission band ­ 3-µm probe 40 fc [kHz] final optimization initial optimization 0 5 10 15 20 v [m/s] 25 30 35 Fig. 14. Results of the initial and final optimization of the transmission band ­ 5-µm probe of final optimization of transmission band was revealed for the velocity of 10 m/s. In the case of low velocities, employment of the second phase of adjustment resulted in the limiting frequency of the system being increases by 20.75 kHz at most. 7. Conclusion Measurement conditions other than those under which the measurement instruments were adjusted may result in their altered processing characteristics. This especially concerns their static characteristics. The need for performing the observations and analyses of high-frequency flow phenomena is connected with the question on dynamics of such systems as well as the question on the effect of external measurement factors on transmission band of measurement systems. The model testing of hot-wire anemometric measurement system presented hereby point to considerable dependence of dynamic response of such instruments on their configuration and/or environmental factors. This became the grounds for the development of conception of a system capable of performing the automatic procedures of self-adjustment in actual measurement conditions. Obtained results of simulation studies confirm the capability of hereby presented system to fulfil such goal and present the basis for realization of actual measurement system based on presented idea. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Archives of Mining Sciences de Gruyter

Dynamic properties of hot-wire anemometric measurement circuits in the aspect of measurements in mine conditions / Właściwości dynamiczne termoanemometrycznych układów pomiarowych w aspekcie pomiarów w warunkach kopalnianych

Loading next page...
 
/lp/de-gruyter/dynamic-properties-of-hot-wire-anemometric-measurement-circuits-in-the-EZZdZgigM0

References (15)

Publisher
de Gruyter
Copyright
Copyright © 2012 by the
ISSN
0860-7001
DOI
10.2478/v10267-012-0045-y
Publisher site
See Article on Publisher Site

Abstract

Arch. Min. Sci., Vol. 57 (2012), No 3, p. 699­714 Electronic version (in color) of this paper is available: http://mining.archives.pl DOI 10.2478/v10267-012-0045-y PAWEL JAMRÓZ*, PAWEL LIGZA*, KATARZYNA SOCHA* DYNAMIC PROPERTIES OF HOT-WIRE ANEMOMETRIC MEASUREMENT CIRCUITS IN THE ASPECT OF MEASUREMENTS IN MINE CONDITIONS WLACIWOCI DYNAMICZNE TERMOANEMOMETRYCZNYCH UKLADÓW POMIAROWYCH W ASPEKCIE POMIARÓW W WARUNKACH KOPALNIANYCH The use of measurement apparatus under conditions which differ significantly from those under which the apparatus was adjusted carries the risk of altering the previously determined measurement characteristics. This is of special concern in the case of apparatus which is sensitive to external measurement conditions. Advanced measurement systems are equipped with algorithms which allow the negative effect of unstable environmental conditions on their static characteristics to be compensated for. Meanwhile, the problem of altered dynamic properties of such systems is often neglected. This paper presents a model study in which the effect of variable operational conditions on dynamic response of hot-wire anemometric measurement system in the case of simulated mine flows was investigated. A mathematical model of measurement system able to compensate the negative effect of changes in flow velocity and configuration of measurement apparatus itself on its dynamic properties was developed and investigated. Based on conducted experiments, we have developed an automatic regulation algorithm enabling the transmission band of measurement apparatus to be optimized for measurement conditions prevailing in mine environment. Keywords: measurements of flow phenomena, transmission band, limiting frequency, hot-wire anemometric measurement systems Stosowanie aparatury pomiarowej w warunkach rónych od warunków, w których aparatura ta byla adjustowana niesie ze sob ryzyko zmian wyznaczonych wczeniej charakterystyk pomiarowych. Dotyczy to w szczególnoci aparatury wraliwej na zewntrzne czynniki pomiarowe. Zaawansowane systemy pomiarowe wyposaa si w algorytmy pozwalajce na kompensacj negatywnego oddzialywania zmiennych warunków rodowiskowych glównie na charakterystyki statyczne. Pomija si czsto przy tym problem zmian wlaciwoci dynamicznych systemów. W artykule przedstawiono modelowe badania wplywu zmiennych warunków uytkowania na odpowied dynamiczn termoanemometrycznego systemu pomiarowego w warunkach pomiarów symulowanych przeplywów kopalnianych. Opracowano i przebadano symulacyjnie matematyczny model ukladu pomiarowego zdolnego do kompensacji negatywnego wplywu * STRATA MECHANICS RESEARCH INSTITUTE OF THE POLISH ACADEMY OF SCIENCES, UL. REYMONTA 27, 30-059 KRAKÓW, POLAND zmian prdkoci przeplywu oraz konfiguracji aparatury pomiarowej na jej wlaciwoci dynamiczne. Na podstawie przeprowadzonych bada stworzono algorytm automatycznej regulacji pozwalajcy na optymalizacj pasma przenoszenia aparatury pomiarowej w warunkach pomiarów w rodowisku kopalnianym. Slowa kluczowe: pomiary zjawisk przeplywowych, pasmo przenoszenia, czstotliwo graniczna, termoanemometryczne uklady pomiarowe 1. Introduction Recently, the development of hot-wire anemometric measurement methods enabled their use not only under precisely specified laboratory conditions, but also in measurement systems which operate in significantly diversified measurement environments. An example of such application is given by measurements performed in mines, where the hot-wire anemometric methods are used to perform measurements of flow velocity profiles in mine galleries (Krawczyk et al., 2011). Among other things, such measurements enable the verification of models of mine ventilation systems with ever-increasing complexity, which for example give consideration to micro-scale phenomena related to measurements of flow turbulence phenomena occurring in near-wall layer (Ligza et al., 2009). Fig. 1. Hot-wire anemometric measurements of ventilation in mine conditions The turbulence is defined as a phenomenon which is random in time and space, and for which the formula determining its value in any given time instant is not possible to be written. Only the probability of occurrence of individual values may be determined for such signal. The analysis of turbulence as a random signal, all characteristic physical quantities of which are of variability random in time and space is based mainly on Reynolds hypothesis. According to this hypothesis, the fluid movement can be treated as a superposition of average and fluctuation movement (Elsner & Drobniak, 1995). Such an analysis is possible only on the basis of empirical results, which may be obtained with the use of hot-wire anemometers. During measurements with the use of hot-wire anemometric measurement systems, problems related to change of dynamic characteristic of hot-wire anemometric systems are often encountered. Their limiting frequency depends on configuration of electronic measurement systems and the environment in which they are being utilized (Watmuff, 1995; Khoo, 1998; Chew et al., 1998; Li, 2005). This comprises one of current scientific problems the solution of which will allow for measurements of random phenomena in turbulent flows to be realized using apparatuses with known metrological properties. It will especially facilitate precise and reliable analysis of measurement results. 2. Dynamic properties of hot-wire anemometric measurement systems Dynamic response of a hot-wire anemometer is related to its voltage or current response to changing velocity and temperature of flowing medium in which the sensor is placed. In order to perform precise determination of such response it would however be necessary to generate the periodically changing velocity field. Nevertheless, with respect to the impossibility of generating such harmonically precisely specified variable fields of flow velocity, such experiments are rather impossible to be performed. Due to this reason, investigations of dynamics of hot-wire anemometric systems are performed with the use of a generator of periodically changing current signal (rectangular wave) incorporated into a hot-wire anemometric circuit. It simulates a step change of velocity generating a specified voltage response which may allows to determine the dynamic properties of the system. For given measurement conditions and given configuration of the hot-wire anemometer, control parameters of measurement system may be adjusted in a way, such that the response of the system to rectangular signal was fifteen percent undershoot. For such settings, the time t is specified as the time at which the system's response reaches 3% of its maximum value. Figure 2 presents the proper response of the hot-wire anemometer obtained with the frequency test, based on which the transmission band of the whole system fc may be assessed according to relationship 1 (Freymuth, 1977). fc = 1 1.3 ×D t (1) Fig. 2. Dynamic characteristic of the hot-wire anemometer The response of the hot-wire anemometric system concerns not only the reaction of the sensor itself to changing flow conditions, but also the reaction of the entire measurement system. The system's dynamics is related not only to physical properties of measuring wire (Jamróz, 2008, 2011) and its operational conditions, but also to characteristics of the apparatus itself, such as electronic parameters of measuring channel and the way in which the signals are brought to/from the measurement probe. Therefore it is necessary that the whole signal processing line be subject to dynamic analysis. The dynamics of the whole system depends on its individual elements. Alterations in any of them results in changes of ideal characteristics of dynamic response of the whole measurement system. Performing measurements by means of hot-wire anemometric apparatus under operational conditions which differ significantly from laboratory ones in which the apparatus was adjusted to ensure its maximum limiting frequency, the system must be capable of adjustment in actual measurement conditions. The hot-wire anemometer capable of automatic self-regulation of its own dynamic properties depending on conditions under which it has to operate would present an optimal solution. In the next section of this study, presented is the simulation study of the effect of external measurement factors on limiting frequency of modelled hot-wire anemometric measurement system developed on the basis of the concept of system allowing for negative effects of external factors on whole system's transmission band to be compensated for. 3. A model of hot-wire anemometric measurement system A simplified scheme of the hot-wire anemometer with potentiometric adjustment of its dynamic properties is presented in Figure 3 (Ligza, 2007). Such a system consists of velocity measurement sensor RS incorporated in one of the branches of resistance bridge and an operational amplifier working in the feedback loop. The sensor together with the resistor RI and the potentiometer P2 comprise a resistance bridge which operates as the resistance comparator system. Fig. 3. The scheme of hot-wire anemometer with potentiometric adjustment of its dynamic properties Dynamic properties of the system are adjusted through incorporating two potentiometers between the upper point and the ground point of the resistance bridge. Sliders of these potentiometers are connected to two-terminal RC network, the terminals of which are appropriately connected to inverting and non-inverting input of measuring amplifier. According to the main concept of the system, adjustment by the potentiometer P1 is to give the possibility to obtain the stable operation of the system following initial optimization of its transmission band. Adjustment by the potentiometer P2, on the other hand, should allow for final optimization of transmission band of the whole system to be obtained. Simulated step changes of the velocity are realized by means of adjusting the offset voltage of operational amplifier U0. For such a system, mathematical model (2) was developed, based on which the series of simulations aimed to determine the influence of external measurement conditions on system's transmission band can possibly be performed. Moreover, it also allows for the possibility of compensation of these effects to be explored. dUC 1 dt æ P RS 12 UA ç R + RI èP + P 11 12 = C1 (R1 + R3) æ ç - U C1 è dUC 2 dt æ P22 PB æ UA ç ç - UC 2 P21 + P22 PA + PB è è = C2 (R2 + R4 ) dUA 1 = - (UA + kA UE ) t dt (2) æ P R R æ R PB æ æ P22 12 UA ç + 1 + 2 ç - UC1 UA ç ç - UC2 A è P11 + P12 R3 R + R I è è P21 + P22 R4 P + PB è UE = + U0 R1 R2 +1 +1 R3 R4 2 dRS ( RS + RI ) = dt UA RS - (AS + BS V S) ( RS - RM ) CS RB RA t = kA RA C , kA = A In this model, consideration is given to dependences describing the hot-wire anemometric sensor allowing for its dynamics as well, with the sensor being described by an instantaneous value of resistance RS and parameters AS, BS, nS and cS which specify the characteristics of the wire in the function of velocity V (Ligza, 2001). Moreover, state variables related to instantaneous values of variable voltages U1 and UC2 as well as to controller circuit UA were specified. 4. The effect of external factors on limiting frequency of the hot-wire anemometer Evaluation of the effect of external factors was performed based on the above presented model of hot-wire anemometer (2). Simulation testing was performed in the Matlab environment utilizing the ode45 function enabling the calculation of differential equations. In the course of simulation, the dynamic response of measurement system in the form of instantaneous values of voltage across the wire URS was determined. The values of parameters used in simulations are presented in Tables 1, 2 and 3. TABLE 1 Parameters of measurement probe containing the 3-um wire RM 5 TM K 293 S 1/K 3.33e-3 AS A2 2e-3 BS cS A2s 0.5e-6 nS 0.5 TABLE 2 s A2 m 0.5e-3 Parameters of measurement probe containing the 5-um wire RM 5 TM K 293 S 1/K 3.33e-3 AS A BS cS As 4e-6 nS 0.5 TABLE 3 4e-3 s A m 2e-3 Exemplary parameters of operational amplifier RA 1e6 A s 15e-3 kA 1e6 TABLE 4 Values of coefficients of the model of hot-wire anemometer RI 10 P 10e3 P1 10e3 P2 10e3 C1 nF 47 C2 pF 350 R1 1e3 R2 100 R3 100 R4 100 4.1. The effect of average flow velocity on dynamic response of the hot-wire anemometer Literature dealing with the dynamic analysis of hot-wire anemometric systems seems to point to strong dependence of limiting frequency of such systems on flow velocity. This dependence is attributable to changes of the intensity of heat exchange between the measuring wire and flowing medium. These changes influence also the nature of the dynamic response of the measurement systems itself. In order to emphasize the magnitude of the effect of flow velocity on limiting frequency of the system, a simulation in which the dynamic response of hot-wire anemometer was optimized for minimum velocity of 0.5 m/s was performed. As a result, the characteristic consistent with the one presented in Figure 2 was obtained. A model of sensor incorporating the measuring wire of 3 µm diameter was used in such simulation. Subsequently, increasing the flow velocity, changes in dynamic response of hot-wire anemometric measurement system were monitored. Results of the simulation are presented in Figure 4. Fig. 4. The effect of average flow velocity on dynamic response of the hot-wire anemometer Together with increasing velocity, the characteristics of dynamic response changes. The undershoot level increases and subsequent maxima occur in the signal of response, which adopts the nature of oscillatory response, leading to unstable operation of the whole measurement system. By default, the procedure of optimization of the dynamic response of hot-wire anemometer is carried out at high velocities. Thanks to this, it is possible to avoid the risk of obtaining the unstable oscillatory operation of measurement system when measurements at lower values of velocity are performed. Figure 5 shows the results of simulation, in which the response of the system optimized with respect to time was obtained for simulated flow velocity of 35 m/s. In this case, the limiting frequency of the system was determined to be equal to 79.76 kHz. In subsequent steps of the simulation, the velocity was gradually reduced to value as low as 0.5 m/s. As the velocity changes, the deformation of previously obtained ideally shaped characteristic of dynamic response of the system occurs, which is associated with deterioration of dynamic properties of the whole measurement system. In the case of the velocity of 15 m/s, the transmission band is maintained at the level of 62.93 kHz, nevertheless, in the case of the velocity of 0.5 m/s, this value decreases down to 43.75 kHz. Fig. 5. The effect of average flow velocity on dynamic response of the hot-wire anemometer 4.2. The probe type and the dynamics of the hot-wire anemometer While performing the measurements under conditions prevailing in mines, there is a high risk of damaging the hot-wire anemometric measurement probe in case of which it might become necessary to replace the sensor with another one. Each probe is characterized by its own individual parameters, such as the wire thickness or resistance. Simulative determination of the effect of changing the probe type on dynamics of the hot-wire anemometric measurement system was performed using the coefficients describing the models of 3-µm and 5-µm probes, presented in Tables 1 and 2, respectively. In the first phase, adjustment of the system was performed in a way which ensured the fastest possible time-response of the hot-wire anemometer equipped with the probe incorporating the 3-µm wire. Subsequently, the dynamic response of the system in which the 3-µm probe was replaced by a 5-µm one was recorded. Investigations were carried out at simulated flow velocity of 20 m/s. Results of the simulation are presented in Figure 6. On the basis of results of simulation, it is possible to conclude, that the change of the probe type results in characteristics of dynamic response of the system to be deformed considerably, such Probe 3 m 1.4 1.2 1 URS [V] URS [V] 0.8 0.6 0.4 0.2 0 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 Probe 5 m 0.5 t [s] 2 t [s] 6 x 10 Fig. 6. The probe type and dynamic response of the hot wire anemometer that they do not allow determining the system's dynamic properties. Conducting measurements of rapidly changing high-frequency phenomena utilizing the system with such characteristic of frequency response does not allow for accurate analysis of measurement results to be performed. In such a case, it is necessary to readjust the system in order to obtain optimal time characteristics of dynamic response of the measurement system. In successive simulation an evaluation of the effect that replacement of measurement probe with the other one of the very same type might potentially have on dynamics of the measurement system was performed. Hot-wire anemometric probes of the same type may differ from each other in values of their resistance. It is caused by the process of their production. An initially optimized dynamic response of the system equipped with the wire of 3 µm in diameter and resistance of 5 for TM = 293 K was analyzed in the simulation. In subsequent phases of investigations, the system's response given the changing resistance of the sensor was recorded. Results of the simulation are presented in Figure 7. Results of conducted simulation point to significant effect of measurement sensor's resistance on obtained transmission band of the whole measurement system. Increase in resistance by 0.3 above the initial value in the same temperature results in observable changes in characteristics of Probe 5 m RM= 5 0.51 URS [V] 0.505 0.5 0.495 0 0.5 t [s] Probe 5 m RM = 5.3 0.525 URS [V] 0.52 0.515 0.51 0.505 0 0.5 t [s] Probe 5 m RM = 5.6 0.54 URS [V] 0.53 0.52 0 0.5 t [s] 1 Fig. 7. The sensor's resistance and dynamic response of the hot wire anemometer dynamic response of the measurement system. These changes require fine adjustment of system's response to obtain optimal characteristics. Higher values of resistance lead to unstable operation of the whole system, which may end up in burn-through of the measurement sensor. 5. Adjustment of dynamic properties In the series of simulations conducted in order to explore the effects of external measurement factors on transmission band of the hot-wire anemometric measurement systems, their considerable effect on shaping of dynamic properties of measurement apparatus was demonstrated. Measurements under conditions prevailing in mines with the use of hot-wire anemometers require compensation methods allowing for negative effects of various factors not only on static characteristics of such devices but also on their dynamic characteristics, to be eliminated. Such compensation is provided by the system presented in Figure 2. In this system, the adjustment takes place by adopting appropriate settings of P1 and P2 potentiometers such that they would ensure that fifteen per cent undershoot in dynamic response of the system is obtained ­ Figure 2. The value of resistance of adjusting potentiometers, for which the system under investigation is characterized by stable yet slow dynamic response, has already been determined on the basis of results of performed model testing (Jamróz et al., 2010). Such response is being recorded for the lowest value of resistance P1 and maximum value of resistance P2. These values were used as starting points for adjustment algorithms. During simulation it was shown, that a series of pairs of settings of potentiometers P11 and P21 exists, for which the dynamic response of the system is consistent with optimum characteristics presented in Figure 2. Results of exemplary simulation illustrating the number of such pairs are presented in Figure 8, in which the black colour designates the areas in which the dynamic Fig. 8. Area of adjustment for flow velocities of 1 and 35 m/s response of the system is in line with the optimum characteristics. Simulations were carried out using the model of the 3-µm probe and for the velocity of 1 and 35 m/s. Areas of adjustment which ensure the obtainment of optimum characteristics of dynamic response of the system change depending on changes of actual values of external measurement factors as well as on electronic configuration of the measurement system itself. In the next part of the study the value of limiting frequency for the above mentioned simulation conditions was determined. Obtained results are presented in Figure 9. Fig. 9. Limiting frequency of the system for flow velocities of 1 and 35 m/s Performed simulation indicate, that the highest values of limiting frequency are obtained for those pairs of resistance of adjusting potentiometers in the case of which the values of resistances P11 and P21 are the highest and the lowest possible, respectively. These are the limiting values of resistance the exceeding of which results in unstable operation of the whole apparatus. 6. The algorithm of automatic optimization of transmission band Employment of digitally adjusted potentiometers allows for algorithm of automatic optimization to be performed. Development of algorithm of automatic adjustment is based on movements along the adjustment characteristic within areas, in which the obtained dynamic response of analyzed object is characterized by properties typical for model response of a hot-wire anemometric measurement system. The process of adjustment takes place until the optimum transmission band of measurement system is obtained. Such an algorithm allows for the widest possible transmission band to be obtained, nevertheless, in order to acquire the desirable effect, prolonged realization of such control process is required. Reduction of time of realization may be achieved by dividing the adjustment process into initial and final optimization steps. 6.1. Initial optimization The first phase of transmission band optimization is based on adjustment realized in several iterations, allowing for initially optimized transmission band of measurement system to be obtained in relatively short time. The principle of this method is presented in the form of an example of simulation performed for 3-µm sensor placed in the flow the velocity of which is equal to 1 m/s. The algorithm of initial optimization was developed on the basis of observation of the process of adjustment of the model and actual measurement system. It is based on adjustment starting from settings which guarantee stable yet slow dynamic response of the system (minimum and maximum values of P11 and P21 resistances, respectively) ­ see Figure 10. Fig. 10. Dynamic response of the model of hot-wire anemometer in the case of starting settings of adjusting potentiometers In the first phase of optimization, the value of resistance P11 is reduced to the level which allows for dynamic response of the measurement system characterized by occurrence of successive periods of over-regulation (with three local maximums) to be obtained ­ see Figure 11. During observations of the process of adjustment of model and actual measurement systems performed for different configurations and under various measurement conditions we noticed, that obtainment of such characteristic, with the starting value of resistance P21 maintained at fixed level at the same time, allows in the next step of adjustment process for the dynamic response of the system to be brought to a form consistent with the one showed in Figure 2. Fig. 11. Dynamic response of the model of hot-wire anemometer after the first phase of the algorithm of initial optimization of transmission band The final step of the adjustment procedure consists in the reduction of the value of resistance P21 to the level, in which the obtained characteristic of dynamic response of the system is as close to the model characteristic as possible. In the analyzed example, employment of automatic algorithm of initial optimization of transmission band allowed for obtainment of dynamic response P11 = 4.99 [k ] P21 = 3.64 [k ] Undershoot 15.07% fc = 52.45 kHz 0.28 0.279 0.278 0.277 URS [V] 0.276 0.275 0.274 0.273 0.272 0 0.5 t [s] 1 Fig. 12. Dynamic response of the model of hot-wire anemometer following the initial optimization of transmission band of the system with limiting frequency equal to 52.45 kHz. Although the obtained transmission band is not optimal for sensors incorporating 3-µm wires, it may still be considered sufficient for the majority of measurement situations. Presented adjustment procedure provides fast optimization of the system with respect to its dynamic properties. Manual optimization process however shows that even wider transmission band can possibly be obtained. It requires an additional adjustment of the system. 6.2. Final optimization Main assumption underlying the procedure of final optimization is to obtain the widest transmission band possible for different configurations of the system and under various measurement conditions. Optimization algorithm starts with the values of resistances P11 and P21 obtained as a result of the process of initial optimization. In the first step of final optimization, the resistance P11 becomes increased by a preset value p1. Subsequently, on the basis of performed measurement of dynamic response of the system, the value of over-regulation is checked. If the value is below 14.8%, the value p2 is reduced by a half and the resistance P21 becomes increased by a new value of p2. If obtained value of undershoot exceeds 15.2%, the resistance P21 becomes reduced by the value of p2. Following each such change of the value of resistance, a measurement of dynamic response of the system is performed. The process of such adjustment takes place until the response with undershoot falling within the range of 14.8÷15.2% is obtained. Acquirement of optimum transmission band is connected with the achievement of ideal characteristics of dynamic response showing only one maximum. Appearance of additional maximum signifies that the signal is over-regulated, therefore the level of this additional maximum in relation to the level of the steady signal may be considered as a criterion of final adjustment. If this criterion is fulfilled, the value of the resistance P1 is increased by p1 and the variable p2 is assigned its initial value. The algorithm of the final optimization ends, if it becomes impossible for subsequent value of P11 increased by the step p1 to find a matching value of the resistance P21 which would ensure the decrease of the magnitude of the additional maximum below the preset limit. It is a criterion, for which the obtained course of dynamic response of the hot-wire anemometer is considered optimal. 6.3. Evaluation of algorithm efficacy For algorithms described above the simulation studies allowing for evaluation of their efficacy in the case of adjustment in flows of different velocities were performed. Results for the 3-µm sensor are presented in Figure 13. As a result of initial optimization procedure, the limiting frequencies ranging from 52.45 kHz for velocity of 1 m/s to 82.83 kHz for 35 m/s were obtained. Conducting the procedure of final optimization of the transmission band leads to a significant improvement of obtained dynamics of the system, especially in the case of low flow velocities. In the case of flow velocity of 1 m/s, the limiting frequency of the system was increased by 13.99 kHz. In the case of higher velocities, achieved increase in limiting frequency was smaller. The value of limiting frequency for velocity of 35 m/s was increased by only 4.02 kHz. Analogous simulation study was performed also for a measurement sensor incorporating the wire of 5 µm in diameter, for which the limiting frequency was determined in a wide range of flow velocities. Alike the case of wire of 3 µm in diameter, the highest efficacy of the algorithm 90 80 70 60 fc [kHz] 50 40 30 20 10 0 0 5 10 15 20 v [m/s] final optimization initial optimization 25 30 35 Fig. 13. Results of the initial and final optimization of the transmission band ­ 3-µm probe 40 fc [kHz] final optimization initial optimization 0 5 10 15 20 v [m/s] 25 30 35 Fig. 14. Results of the initial and final optimization of the transmission band ­ 5-µm probe of final optimization of transmission band was revealed for the velocity of 10 m/s. In the case of low velocities, employment of the second phase of adjustment resulted in the limiting frequency of the system being increases by 20.75 kHz at most. 7. Conclusion Measurement conditions other than those under which the measurement instruments were adjusted may result in their altered processing characteristics. This especially concerns their static characteristics. The need for performing the observations and analyses of high-frequency flow phenomena is connected with the question on dynamics of such systems as well as the question on the effect of external measurement factors on transmission band of measurement systems. The model testing of hot-wire anemometric measurement system presented hereby point to considerable dependence of dynamic response of such instruments on their configuration and/or environmental factors. This became the grounds for the development of conception of a system capable of performing the automatic procedures of self-adjustment in actual measurement conditions. Obtained results of simulation studies confirm the capability of hereby presented system to fulfil such goal and present the basis for realization of actual measurement system based on presented idea.

Journal

Archives of Mining Sciencesde Gruyter

Published: Dec 1, 2012

There are no references for this article.