Analysis of temperature distribution in a pipe with inner mineral deposit

Analysis of temperature distribution in a pipe with inner mineral deposit Abstract The paper presents the results of calculations related to determination of temperature distributions in a steel pipe of a heat exchanger taking into account inner mineral deposits. Calculations have been carried out for silicate-based scale being characterized by a low heat transfer coefficient. Deposits of the lowest values of heat conduction coefficient are particularly impactful on the strength of thermally loaded elements. In the analysis the location of the thermocouple and the imperfection of its installation were taken into account. The paper presents the influence of determination accuracy of the heat flux on the pipe external wall on temperature distribution. The influence of the heat flux disturbance value on the thickness of deposit has also been analyzed. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Archives of Thermodynamics de Gruyter

Analysis of temperature distribution in a pipe with inner mineral deposit

Loading next page...
 
/lp/de-gruyter/analysis-of-temperature-distribution-in-a-pipe-with-inner-mineral-20fi7yemeD

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
de Gruyter
Copyright
Copyright © 2014 by the
ISSN
2083-6023
eISSN
2083-6023
DOI
10.2478/aoter-2014-0012
Publisher site
See Article on Publisher Site

Abstract

Abstract The paper presents the results of calculations related to determination of temperature distributions in a steel pipe of a heat exchanger taking into account inner mineral deposits. Calculations have been carried out for silicate-based scale being characterized by a low heat transfer coefficient. Deposits of the lowest values of heat conduction coefficient are particularly impactful on the strength of thermally loaded elements. In the analysis the location of the thermocouple and the imperfection of its installation were taken into account. The paper presents the influence of determination accuracy of the heat flux on the pipe external wall on temperature distribution. The influence of the heat flux disturbance value on the thickness of deposit has also been analyzed.