Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Post-fire assessment and reinstatement of steel structures

Post-fire assessment and reinstatement of steel structures <jats:sec> <jats:title content-type="abstract-subheading">Purpose</jats:title> <jats:p>This paper aims to present technical aspects of the assessment method and evaluation of fire damaged steel structures. The current work focuses on the behavior of structural normal steel (hot-rolled and cold-formed) and high-strength bolts after exposure to elevated temperatures. Information on stainless steel, cast iron and wrought iron is also presented.</jats:p> </jats:sec> <jats:sec> <jats:title content-type="abstract-subheading">Design/methodology/approach</jats:title> <jats:p>Because of the complexity of the issue, an elaborate presentation of the mechanical properties influencing factors is followed. Subsequently, a wide range of experimental studies is extensively reviewed in the literature while simplified equations for determining the post-fire mechanical properties are proposed, following appropriate categorization. Moreover, the reinstatement survey is also comprehensively described.</jats:p> </jats:sec> <jats:sec> <jats:title content-type="abstract-subheading">Findings</jats:title> <jats:p>Useful conclusions are drawn for the safe reuse of the structural elements and connection components. According to the parametric investigation of the aforementioned data, it can be safely concluded that the most common scenario of buildings after fire events, i.e. apart from excessively distorted structures, implies considerable remaining capacity of the structure, highlighting that subsequent demolition should not be the case, especially regarding critical infrastructure and buildings.</jats:p> </jats:sec> <jats:sec> <jats:title content-type="abstract-subheading">Originality/value</jats:title> <jats:p>The stability of the structure as a whole is addressed, with aim to establish specific guidelines and code provisions for the correct appraisal and rehabilitation of fire damaged structures.</jats:p> </jats:sec> http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Structural Fire Engineering CrossRef

Post-fire assessment and reinstatement of steel structures

Journal of Structural Fire Engineering , Volume 8 (2): 181-201 – Jun 12, 2017

Post-fire assessment and reinstatement of steel structures


Abstract

<jats:sec>
<jats:title content-type="abstract-subheading">Purpose</jats:title>
<jats:p>This paper aims to present technical aspects of the assessment method and evaluation of fire damaged steel structures. The current work focuses on the behavior of structural normal steel (hot-rolled and cold-formed) and high-strength bolts after exposure to elevated temperatures. Information on stainless steel, cast iron and wrought iron is also presented.</jats:p>
</jats:sec>
<jats:sec>
<jats:title content-type="abstract-subheading">Design/methodology/approach</jats:title>
<jats:p>Because of the complexity of the issue, an elaborate presentation of the mechanical properties influencing factors is followed. Subsequently, a wide range of experimental studies is extensively reviewed in the literature while simplified equations for determining the post-fire mechanical properties are proposed, following appropriate categorization. Moreover, the reinstatement survey is also comprehensively described.</jats:p>
</jats:sec>
<jats:sec>
<jats:title content-type="abstract-subheading">Findings</jats:title>
<jats:p>Useful conclusions are drawn for the safe reuse of the structural elements and connection components. According to the parametric investigation of the aforementioned data, it can be safely concluded that the most common scenario of buildings after fire events, i.e. apart from excessively distorted structures, implies considerable remaining capacity of the structure, highlighting that subsequent demolition should not be the case, especially regarding critical infrastructure and buildings.</jats:p>
</jats:sec>
<jats:sec>
<jats:title content-type="abstract-subheading">Originality/value</jats:title>
<jats:p>The stability of the structure as a whole is addressed, with aim to establish specific guidelines and code provisions for the correct appraisal and rehabilitation of fire damaged structures.</jats:p>
</jats:sec>

Loading next page...
 
/lp/crossref/post-fire-assessment-and-reinstatement-of-steel-structures-pFhIE4Y6yi

References (26)

Publisher
CrossRef
ISSN
2040-2317
DOI
10.1108/jsfe-03-2017-0028
Publisher site
See Article on Publisher Site

Abstract

<jats:sec> <jats:title content-type="abstract-subheading">Purpose</jats:title> <jats:p>This paper aims to present technical aspects of the assessment method and evaluation of fire damaged steel structures. The current work focuses on the behavior of structural normal steel (hot-rolled and cold-formed) and high-strength bolts after exposure to elevated temperatures. Information on stainless steel, cast iron and wrought iron is also presented.</jats:p> </jats:sec> <jats:sec> <jats:title content-type="abstract-subheading">Design/methodology/approach</jats:title> <jats:p>Because of the complexity of the issue, an elaborate presentation of the mechanical properties influencing factors is followed. Subsequently, a wide range of experimental studies is extensively reviewed in the literature while simplified equations for determining the post-fire mechanical properties are proposed, following appropriate categorization. Moreover, the reinstatement survey is also comprehensively described.</jats:p> </jats:sec> <jats:sec> <jats:title content-type="abstract-subheading">Findings</jats:title> <jats:p>Useful conclusions are drawn for the safe reuse of the structural elements and connection components. According to the parametric investigation of the aforementioned data, it can be safely concluded that the most common scenario of buildings after fire events, i.e. apart from excessively distorted structures, implies considerable remaining capacity of the structure, highlighting that subsequent demolition should not be the case, especially regarding critical infrastructure and buildings.</jats:p> </jats:sec> <jats:sec> <jats:title content-type="abstract-subheading">Originality/value</jats:title> <jats:p>The stability of the structure as a whole is addressed, with aim to establish specific guidelines and code provisions for the correct appraisal and rehabilitation of fire damaged structures.</jats:p> </jats:sec>

Journal

Journal of Structural Fire EngineeringCrossRef

Published: Jun 12, 2017