Erratum: Imaging spin diffusion in germanium at room temperature [Phys. Rev. B 96, 014403 (2017)]

Erratum: Imaging spin diffusion in germanium at room temperature [Phys. Rev. B 96, 014403 (2017)] PHYSICAL REVIEW B 96, 059901(E) (2017) Erratum: Imaging spin diffusion in germanium at room temperature [Phys. Rev. B 96, 014403 (2017)] C. Zucchetti, F. Bottegoni, C. Vergnaud, F. Ciccacci, G. Isella, L. Ghirardini, M. Celebrano, F. Rortais, A. Ferrari, A. Marty, M. Finazzi, and M. Jamet (Received 25 July 2017; published 7 August 2017) DOI: 10.1103/PhysRevB.96.059901 The x axes of Fig. 3 report the wrong units. The correct units should be micrometers instead of millimeters. 08 4 8 12 16 0 4 12 16 1 1 (a) (b) 0 0 4 16 (c) (d) 0 0 -4 -16 (e) (f) 2 8 0 0 -2 -8 -4 -16 (g) (h) R R 0 4 812 16 0 4 8 12 16 x position (μm) x position (μm) FIG. 3. (a) and (b) Reflectivity (R) optical images recorded on the magnetic tunnel junction (MTJ) and inverse spin Hall effect (ISHE) devices, respectively. (c) and (d) Corresponding simultaneously recorded MTJ and ISHE voltage signals. The incident power is 60 μW for the MTJ sensor and 900 μW for the ISHE detector. (e) and (f) Voltage profiles along x across the centers of the Pt pads. In both cases, the detector is http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Physical Review B American Physical Society (APS)

Erratum: Imaging spin diffusion in germanium at room temperature [Phys. Rev. B 96, 014403 (2017)]

Preview Only

Erratum: Imaging spin diffusion in germanium at room temperature [Phys. Rev. B 96, 014403 (2017)]

Abstract

PHYSICAL REVIEW B 96, 059901(E) (2017) Erratum: Imaging spin diffusion in germanium at room temperature [Phys. Rev. B 96, 014403 (2017)] C. Zucchetti, F. Bottegoni, C. Vergnaud, F. Ciccacci, G. Isella, L. Ghirardini, M. Celebrano, F. Rortais, A. Ferrari, A. Marty, M. Finazzi, and M. Jamet (Received 25 July 2017; published 7 August 2017) DOI: 10.1103/PhysRevB.96.059901 The x axes of Fig. 3 report the wrong units. The correct units should be micrometers instead of millimeters. 08 4 8 12 16 0 4 12 16 1 1 (a) (b) 0 0 4 16 (c) (d) 0 0 -4 -16 (e) (f) 2 8 0 0 -2 -8 -4 -16 (g) (h) R R 0 4 812 16 0 4 8 12 16 x position (μm) x position (μm) FIG. 3. (a) and (b) Reflectivity (R) optical images recorded on the magnetic tunnel junction (MTJ) and inverse spin Hall effect (ISHE) devices, respectively. (c) and (d) Corresponding simultaneously recorded MTJ and ISHE voltage signals. The incident power is 60 μW for the MTJ sensor and 900 μW for the ISHE detector. (e) and (f) Voltage profiles along x across the centers of the Pt pads. In both cases, the detector is
Loading next page...
 
/lp/aps_physical/erratum-imaging-spin-diffusion-in-germanium-at-room-temperature-phys-Z2hxkEGg1u
Publisher
The American Physical Society
Copyright
Copyright © ©2017 American Physical Society
ISSN
1098-0121
eISSN
1550-235X
D.O.I.
10.1103/PhysRevB.96.059901
Publisher site
See Article on Publisher Site

Abstract

PHYSICAL REVIEW B 96, 059901(E) (2017) Erratum: Imaging spin diffusion in germanium at room temperature [Phys. Rev. B 96, 014403 (2017)] C. Zucchetti, F. Bottegoni, C. Vergnaud, F. Ciccacci, G. Isella, L. Ghirardini, M. Celebrano, F. Rortais, A. Ferrari, A. Marty, M. Finazzi, and M. Jamet (Received 25 July 2017; published 7 August 2017) DOI: 10.1103/PhysRevB.96.059901 The x axes of Fig. 3 report the wrong units. The correct units should be micrometers instead of millimeters. 08 4 8 12 16 0 4 12 16 1 1 (a) (b) 0 0 4 16 (c) (d) 0 0 -4 -16 (e) (f) 2 8 0 0 -2 -8 -4 -16 (g) (h) R R 0 4 812 16 0 4 8 12 16 x position (μm) x position (μm) FIG. 3. (a) and (b) Reflectivity (R) optical images recorded on the magnetic tunnel junction (MTJ) and inverse spin Hall effect (ISHE) devices, respectively. (c) and (d) Corresponding simultaneously recorded MTJ and ISHE voltage signals. The incident power is 60 μW for the MTJ sensor and 900 μW for the ISHE detector. (e) and (f) Voltage profiles along x across the centers of the Pt pads. In both cases, the detector is

Journal

Physical Review BAmerican Physical Society (APS)

Published: Aug 7, 2017

There are no references for this article.

Sorry, we don’t have permission to share this article on DeepDyve,
but here are related articles that you can start reading right now:

Explore the DeepDyve Library

Search

Query the DeepDyve database, plus search all of PubMed and Google Scholar seamlessly

Organize

Save any article or search result from DeepDyve, PubMed, and Google Scholar... all in one place.

Access

Get unlimited, online access to over 18 million full-text articles from more than 15,000 scientific journals.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve

Freelancer

DeepDyve

Pro

Price

FREE

$49/month
$360/year

Save searches from
Google Scholar,
PubMed

Create lists to
organize your research

Export lists, citations

Read DeepDyve articles

Abstract access only

Unlimited access to over
18 million full-text articles

Print

20 pages / month

PDF Discount

20% off