Erratum: Controlling the magnetic-field sensitivity of atomic-clock states by microwave dressing [Phys. Rev. A 90, 053416 (2014)]

Erratum: Controlling the magnetic-field sensitivity of atomic-clock states by microwave dressing... PHYSICAL REVIEW A 96, 019901(E) (2017) Erratum: Controlling the magnetic-field sensitivity of atomic-clock states by microwave dressing [Phys. Rev. A 90, 053416 (2014)] L. Sárkány, P. Weiss, H. Hattermann, and J. Fortágh (Received 22 June 2017; published 6 July 2017) DOI: 10.1103/PhysRevA.96.019901 A typographical error in the article needs to be corrected. Equation (11) in the article should read 3 1/2 3/2 2 2 E /h¯ = ω + (μ − μ )B + 6βB −  + + . (11) 0,1 0 2 1 dress (B)  (B)  (B) 1 2 3 We have ensured that all calculations in the article were made with the correct equation. Hence, all comparisons between experimental data and theory and the conclusions are unaffected by this. The authors would like to thank Dr. Daniel Bothner for pointing out this error. 2469-9926/2017/96(1)/019901(1) 019901-1 ©2017 American Physical Society http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Physical Review A American Physical Society (APS)

Erratum: Controlling the magnetic-field sensitivity of atomic-clock states by microwave dressing [Phys. Rev. A 90, 053416 (2014)]

Preview Only

Erratum: Controlling the magnetic-field sensitivity of atomic-clock states by microwave dressing [Phys. Rev. A 90, 053416 (2014)]

Abstract

PHYSICAL REVIEW A 96, 019901(E) (2017) Erratum: Controlling the magnetic-field sensitivity of atomic-clock states by microwave dressing [Phys. Rev. A 90, 053416 (2014)] L. Sárkány, P. Weiss, H. Hattermann, and J. Fortágh (Received 22 June 2017; published 6 July 2017) DOI: 10.1103/PhysRevA.96.019901 A typographical error in the article needs to be corrected. Equation (11) in the article should read 3 1/2 3/2 2 2 E /h¯ = ω + (μ − μ )B + 6βB −  + + . (11) 0,1 0 2 1 dress (B)  (B)  (B) 1 2 3 We have ensured that all calculations in the article were made with the correct equation. Hence, all comparisons between experimental data and theory and the conclusions are unaffected by this. The authors would like to thank Dr. Daniel Bothner for pointing out this error. 2469-9926/2017/96(1)/019901(1) 019901-1 ©2017 American Physical Society
Loading next page...
 
/lp/aps_physical/erratum-controlling-the-magnetic-field-sensitivity-of-atomic-clock-sUN6rSrb4W
Publisher
The American Physical Society
Copyright
Copyright © ©2017 American Physical Society
ISSN
1050-2947
eISSN
1094-1622
D.O.I.
10.1103/PhysRevA.96.019901
Publisher site
See Article on Publisher Site

Abstract

PHYSICAL REVIEW A 96, 019901(E) (2017) Erratum: Controlling the magnetic-field sensitivity of atomic-clock states by microwave dressing [Phys. Rev. A 90, 053416 (2014)] L. Sárkány, P. Weiss, H. Hattermann, and J. Fortágh (Received 22 June 2017; published 6 July 2017) DOI: 10.1103/PhysRevA.96.019901 A typographical error in the article needs to be corrected. Equation (11) in the article should read 3 1/2 3/2 2 2 E /h¯ = ω + (μ − μ )B + 6βB −  + + . (11) 0,1 0 2 1 dress (B)  (B)  (B) 1 2 3 We have ensured that all calculations in the article were made with the correct equation. Hence, all comparisons between experimental data and theory and the conclusions are unaffected by this. The authors would like to thank Dr. Daniel Bothner for pointing out this error. 2469-9926/2017/96(1)/019901(1) 019901-1 ©2017 American Physical Society

Journal

Physical Review AAmerican Physical Society (APS)

Published: Jul 6, 2017

There are no references for this article.

Sorry, we don’t have permission to share this article on DeepDyve,
but here are related articles that you can start reading right now:

Explore the DeepDyve Library

Search

Query the DeepDyve database, plus search all of PubMed and Google Scholar seamlessly

Organize

Save any article or search result from DeepDyve, PubMed, and Google Scholar... all in one place.

Access

Get unlimited, online access to over 18 million full-text articles from more than 15,000 scientific journals.

Your journals are on DeepDyve

Read from thousands of the leading scholarly journals from SpringerNature, Elsevier, Wiley-Blackwell, Oxford University Press and more.

All the latest content is available, no embargo periods.

See the journals in your area

DeepDyve

Freelancer

DeepDyve

Pro

Price

FREE

$49/month
$360/year

Save searches from
Google Scholar,
PubMed

Create lists to
organize your research

Export lists, citations

Read DeepDyve articles

Abstract access only

Unlimited access to over
18 million full-text articles

Print

20 pages / month

PDF Discount

20% off