SIMPLE, RAPID DIAGNOSTIC TEST FOR RHEUMATOID ARTHRITIS-BENTONITE FLOCCULATION TEST

SIMPLE, RAPID DIAGNOSTIC TEST FOR RHEUMATOID ARTHRITIS-BENTONITE FLOCCULATION TEST The bentonite flocculation test (BFT) is a modification of a serologic test used to detect Trichinella antibodies. Ingredients for the test are readily available from commercial sources. Stock preparations are stable for months. Equipment necessary for this test is available in the average clinical laboratory. Minimal technical skill is required for performance of the test and reading of results. One hour or less is required from receipt of the serum to completion of the test. Of 114 patients with verified rheumatoid arthritis, the test finding was positive in 85%. Disseminated lupus erythematosus and scleroderma contributed the next highest percentage of positive tests, 55% and 50 % respectively. In 58 patients with nonrheumatoid arthritis, the test finding was positive in 3 (5%). The BFT result is positive in about 10% of syphilitic as well as biological false-positive serums. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png JAMA American Medical Association

SIMPLE, RAPID DIAGNOSTIC TEST FOR RHEUMATOID ARTHRITIS-BENTONITE FLOCCULATION TEST

JAMA , Volume 169 (4) – Jan 24, 1959

Loading next page...
 
/lp/american-medical-association/simple-rapid-diagnostic-test-for-rheumatoid-arthritis-bentonite-GSCnVO0wDb

References (11)

Publisher
American Medical Association
Copyright
Copyright © 1959 American Medical Association. All Rights Reserved. Applicable FARS/DFARS Restrictions Apply to Government Use.
ISSN
0098-7484
eISSN
1538-3598
DOI
10.1001/jama.1959.03000210001001
Publisher site
See Article on Publisher Site

Abstract

The bentonite flocculation test (BFT) is a modification of a serologic test used to detect Trichinella antibodies. Ingredients for the test are readily available from commercial sources. Stock preparations are stable for months. Equipment necessary for this test is available in the average clinical laboratory. Minimal technical skill is required for performance of the test and reading of results. One hour or less is required from receipt of the serum to completion of the test. Of 114 patients with verified rheumatoid arthritis, the test finding was positive in 85%. Disseminated lupus erythematosus and scleroderma contributed the next highest percentage of positive tests, 55% and 50 % respectively. In 58 patients with nonrheumatoid arthritis, the test finding was positive in 3 (5%). The BFT result is positive in about 10% of syphilitic as well as biological false-positive serums.

Journal

JAMAAmerican Medical Association

Published: Jan 24, 1959